Aarrow Fires Tf 70 Servicing Maintenance, Chimney Sweeping, Door Glass, Outer Finish

Page 14

SERVICING

MAINTENANCE

It is important that your fire is regularly serviced in accordance with these instructions. This should be carried out at least annually by a qualified person and should consist of the following:

When the appliance is cold and unlit ensure to remove the firebrick liners and throat plate. Inspect all gasketing on doors, glass etc., and re-order any items that may need replacing, from your Aarrow dealer. With a wire brush clean inside the appliance paying particular attention to the small inlet holes of the air wash on the inside, above the fire door and to the door. With Ti40 models ensure to sweep up around the damper flap regularly to avoid ash build up.

Sweep the chimney and confirm that it is sound. Examine all joints in the flue pipe etc., and re-seal if necessary. Reassemble and leave with the air inlet and air wash control about half way open. This will allow a free flow of air through the appliance thus preventing moisture and condensation from building up inside the fire and chimney.

CHIMNEY SWEEPING

Sweeping should be carried out with an appropriate sized bristle brush and rods to suit chimney size and type. As with all appliances regular sweeping of the flue is essential to avoid the danger of blockage and the escape of poisonous fumes. Access for cleaning should also be incorporated in the chimney (e.g. soot door or access through register plate).

Any existing chimney should be swept prior to installation of the appliance, and swept again a second time within one month of regular use after installation to establish frequency of sweeping required. This should be done by a competent person such as a NACS chimney engineers who will provide a Certificate of Chimney Sweeping.

Sweep the whole flue way, including the outlet, at least twice per burning season. It is important that the flue ways, flue pipe and chimney be cleaned prior to lighting the fire after a prolonged shut-down period.

DOOR GLASS

The door glass should remain clear during normal daytime burning. However under certain conditions- such as burning at a low rate with damp wood, or overnight burning, the glass may become somewhat blackened. To remedy this, operate the appliance at a fast rate. Alternatively when the stove is cold open the door and clean the inside face of the glass with a damp cloth or with glass cleaner (available from fire stockists). A piece of cloth moistened with vinegar and dipped in wood ash - not coal ash - will provide a good soft scourer to remove the soot without scratching the glass.

OUTER FINISH

The outside finish of the appliance is a durable high temperature paint. It is best cleaned by brushing down with a clean shoe brush. Do not allow moisture to remain on the appliance whilst cold or surface rust may form.

The high temperature paint should not require attention for some time, depending on use. The hotter the fire burns the sooner repainting will be necessary. Aerosol tins of paint are available for complete refurbishing. Before repainting make sure that the fire is out and is cold.

•Remove the door glass.

•Lightly wire brush, or rub with wire wool, the body of the appliance to remove any loose paint powder.

•Mask or remove items such as brass work.

•Any adjacent brickwork, mantelpiece, hearth, etc., should be carefully masked for quite a distance around the appliance. (this precaution is to prevent discolouration of the surrounding brick work, wallpaper etc).

Re-spray in a well-ventilated area - avoid breathing the vapour. Refer to safety instructions on paint cans.

•When the paint is dry refit door glass and any other parts previously removed.

•Leave the appliance for eight hours before re-lighting.

•Burn slowly for the first four hours, then build up heat gradually to cure the paint.

Note: Use only genuine Aarrow touch-up spray as some paints interact. This could ruin the finish and invalidate the guarantee.

14

Stratford Tf & Ti Multifuel Boiler

Image 14
Contents Stratford Tf & Ti Multifuel Boiler Stoves Copyright Contents Petroleum Coke Introduction Safety Principle of the FireTf 70b Check ListPart Description Stratford Visual Aid Tf 30b Not to scale1kW = 3420 BTU’s 25.4mm = 1 inch Technical DataStratford Tf 30b AIR Inlet Controls Operating Instructions Multifuel GrateAarrow AIR Wash System Thermostatic ControlRiddling Operating Instructions Interlock SystemMulti Purpose Operating Tool Door TrimFuel Retainer Bars Door AdjustmentOperating Instructions Recommended Reading Operating Instructions Fuel TypesLighting the Fire Mixed Fuels Overnight BurningBurning Wood AnthraciteOVER-FIRING CleaningAccessories Door Glass Servicing MaintenanceChimney Sweeping Outer FinishInstallation General Precautions Assembling the Grate Installation Multifuel GrateGrate BAR Replacement Throat Plate InspectionInstallation Fitting the Flue Outlet and HOT Plate Flues and ChimneysInstallation For ALL AppliancesSee below if adjustment is required Installation Integral BoilersAdjustment Thermostat To fit/remove thermostat on Tf modelsBuilders Opening / Chimney Breast FlueInstallation Installation Installation Stratford Tf & Ti Multifuel Boiler Stoves Boiler Tapping Positions Boiler Tapping Positions Stratford Ti 40 Inset Boiler Tapping Positions Installation Water Connections Heating systemsHOT Water Systems HOT Water SystemsChecklist Part Description Tf 30b Tf 50b Tf 70bParts List Tf 30b Tf 50b Tf 70b Tf 90b CombStamp is required GuaranteeCustomer Registration Service Record Date of Visit Company Work Carried Out Signature’ve checked it and it’s O.K Final Factory Check List