Emulex 355 manual General Switch Settings, Switch Identification, Network Location

Page 22

EMULEX MODEL 355 SAN STORAGE SWITCH

CHAPTER 3: SWITCH MANAGEMENT

USERS GUIDE

General Switch Settings

The Switch Configuration page displays general settings and switch identification information.

To view the Switch Configuration page, click Switch > Configuration.

Figure 3-3: Switch Configuration page

Switch Identification

This section includes general switch identification information.

Setting

Description

 

 

Name

The name of the switch.

 

 

Location

The location of the switch.

 

 

Contact Name

The person or group to contact about the switch.

 

 

Serial Number

A unique identification number assigned to each switch at the factory. This

 

setting cannot be configured or modified.

 

 

The name, location, and contact name information may be modified for the network environment. The Serial Number setting is factory set and cannot be modified.

To change the name, location, or contact name:

1.Click Switch > Configuration.

2.Enter the new value in the appropriate text box.

3.Click Submit.

The Switch Configuration page displays the updated information.

Network Location

The switch’s network location is identified by the IP Address, Netmask, and Gateway fields.

 

Setting

Description

 

 

 

 

 

 

Ethernet IP Address

The current IP Address for the switch.

 

 

 

 

 

 

Netmask

The current IP Netmask address for the switch.

 

 

 

 

 

 

Default Gateway

The current Gateway address for the switch.

 

 

 

 

 

 

 

 

 

 

 

EMULEX CORPORATION

19

 

 

PART NUMBER 00041407-002 REV. B

 

Image 22
Contents Model ART N Umber 00041407-002 R EV. B Table of Contents Chapter Introduction OverviewFeatures Inspeed TechnologyInstallation Preparation To unpack the switchSwitch can be installed in a rack or placed on a desktop Rack InstallationSwitch Installation To install the switches in the trayTo place the switch on a desktop Desktop InstallationUL Guidelines for Mounting Equipment in a Rack Ethernet LEDs Switch LedsEthernet LEDs indicate the network connection status System LEDs Port LEDs SFP Status Port BypassedRemoving an SFP Installing an SFPAttaching a Device to the Switch SFP CompatibilityBooting the Switch and SAN To boot the switch and SANChapter Switch Management Getting Started Configuring the Network InterfaceTo connect through a serial interface Cancel Connecting to the Web ManagerCommand Button Description Submit Web Manager OverviewDocumentation Command Button Description RebootLogin/Logout RefreshChange the Password Initial Switch SetupLog in to the Switch To log in to the switchTo set the date and time settings Change the Switch NameTo view the current date and time Click Switch Date & Time To change the switch name Click Switch ConfigurationManaging the Switch Frequent Switch Configuration TasksTo change a switch setting Logging in to the SwitchConfiguring the Switch Settings To reset the switchSwitch Identification General Switch SettingsNetwork Location Version Information Switch SpeedTo change the switch speed Click Switch Configuration Blocking ARBSetting Snmp Traps To configure an Snmp trapTo change the time Click Switch Date & Time Configuring Date and Time SettingsTo synchronize time with the host system Click Host Time Switch Password page appears Changing the PasswordOpening a Telnet Session Switch Thresholds page appears Adjusting the Switch ThresholdsTo change switch thresholds or time intervals To view the Port Smart Settings Click Port Smart Settings Configuring the Port Smart SettingsPort Smart Settings page appears Default Smart Settings To set all ports to the currently selected Smart Setting Creating Custom Smart SettingsTo assign a Smart Setting to one or more ports To create a custom Smart SettingTo rename a custom Smart Setting Smart Setting AssignmentsTo modify a custom Smart Setting To delete a custom Smart SettingFollowing settings are available Pre-Insertion TestingPort Information Manager Setting Description Stealth Intelligent ChangeChange Notifications Change Notification onPort Recovery Setting Description Port Control Managing Firmware and Configuration FilesDiagnostics Bypass on Clock DeltaSwitch Firmware Files Switch Configuration FilesTo restore the factory default configuration Restoring the Factory Default SettingsOne-Step Zoning To remove a port from a zone To add ports to a zoneTo activate zoning To remove all ports from a zoneSingle-Switch Zoning 13 Devices in a Single ZoneAdding Devices to Multiple Zones To add storage devices to multiple zonesMultiple Switch Zoning 17 Devices in Multiple Zones Across Multiple SwitchesRecovering a Bad Zone Automatically Alpa ZoningConnecting Ports Through Hard Zoning To set up Hard ZoningString Cascades Cascading SwitchesTree Cascades Automatic Trunking 22 Automatic Trunking exampleLoad Balancing 23 Advanced Functions Automatic TrunkingTo change the load balancing settings Load IndicatorsFairness and Prioritization Switch Information Viewing Switch StatusMonitoring the Switch Current status is provided for the following itemsYellow Port Utilization and HealthPort Color Indication Green RedEvent Log Messages page appears To view the event log Click Switch Event LogViewing the Event Log Last time the event log was polled appears at the topTo view port information Click Port Information Viewing Port InformationPort Information page appears Value Description High Viewing Port UtilizationPort Utilization page appears AverageViewing Port Diagnostics Port Diagnostics page appearsManual Port Operation To save diagnostic informationTo reset a port Click Advanced Functions Diagnostics Port To clear the countersViewing Ordered Sets Change CRC ErrorDetection Indication F7 Initialization Notification UnknownTroubleshooting Device Connections Troubleshooting Management Connections Port Bypass Conditions and RecoveryDefault Smart Setting Attributes Fibre Channel References Appendixes Switch Specifications Operating ConditionsTo connect through a network interface Connecting to the CLILogging in and OUT To log in to the CLIUsing the CLI Frequent Switch Configuration TasksCLI Commands Severity Description Level Event Event Message SeverityInterswitch link added/removed Error during Port DiscPort Ptbi failed due to timeout LIP Cycle TimeoutArbitrated Loop Physical Addresses Hex DecimalArbitration Alpa or Arbitrated LoopPhysical Address Current Fill WordIndex SFP Part Number 00041407-002 REV. B
Related manuals
Manual 74 pages 23.77 Kb

355 specifications

The Emulex 355 is a high-performance network interface card (NIC) designed specifically for data centers requiring advanced connectivity, reliability, and speed. With the rapid evolution of data transmission technology, the Emulex 355 stands out due to its robust features and capabilities that cater to the demands of modern IT infrastructures.

One of the key features of the Emulex 355 is its support for 10 Gigabit Ethernet, which allows for significantly faster data transfer rates compared to standard Gigabit connections. This increased bandwidth is essential for handling large volumes of data traffic, particularly in virtualized environments and cloud computing applications. Its high throughput ensures that data can be transmitted rapidly across networks, minimizing latency and improving overall performance.

The Emulex 355 employs advanced technologies such as iSCSI Offload and FCoE (Fibre Channel over Ethernet), which help enhance data processing efficiency. These technologies allow the card to offload processing tasks from the host system's CPU, reducing the load on server resources and optimizing performance. The result is a more efficient system that can handle more concurrent connections and processes without being overwhelmed.

In addition to speed and efficiency, reliability is paramount in data center operations. The Emulex 355 includes features like error detection and correction, ensuring data integrity during transmission. Built-in redundancy and failover capabilities safeguard against potential network disruptions, allowing for continuous availability of services—a crucial aspect in mission-critical environments.

The Emulex 355 also offers support for various robust networking protocols, enabling seamless integration into existing network infrastructures. Its compatibility with multiple operating systems and virtualization platforms, such as VMware and Microsoft Hyper-V, further enhances its versatility.

Another notable characteristic of the Emulex 355 is its energy-efficient design. It is optimized for lower power consumption without sacrificing performance, aligning with contemporary efforts to reduce the carbon footprint in data centers.

In conclusion, the Emulex 355 NIC is a powerful solution equipped with features that address the complex demands of modern data centers. Its combination of speed, reliability, and efficiency, along with advanced technologies, makes it a preferred choice for organizations looking to enhance their network capabilities and ensure smooth, uninterrupted operations.