Emulex 355 manual Port Information, Pre-Insertion Testing, Following settings are available

Page 32

EMULEX MODEL 355 SAN STORAGE SWITCH

CHAPTER 3: SWITCH MANAGEMENT

USERS GUIDE

Port Information

The following settings are available.

Setting

Description

 

 

Smart Setting Name

Displays the name of the Smart Setting. The Smart Setting name will

 

automatically appear in the text box when selected in the scroll menu.

 

 

Smart Setting Type

The topology among switches for a port. Options include:

 

• Initiator or Target Port – the default setting. Should be used when

 

there are no links between switches.

 

• Tree Cascade – designates the port as a tree cascade port. Use

 

this setting when connecting multiple switches together in a tree

 

cascade configuration. Under most conditions, this setting will

 

result in acceptable performance.

 

• String Cascade 1 through String Cascade 4 – designates the string

 

cascade to which a port is assigned. String cascades maintain

 

fairness when two or more InSpeed-based storage switches are

 

serially cascaded. Switch performance may be lower when

 

compared to a tree cascade configuration.

 

 

Pre-Insertion Testing

The following settings are available.

Setting

Description

 

 

Enable Policies/Smart

This policy is the default operating mode for all ports and determines

Insertion

what the switch looks for prior to allowing a port to insert into a zone.

 

When the policy is enabled, an external device is sent an F7

 

Initialization notification by the switch until an F7 Initialization

 

notification is received from the device. Once an F7 Initialization

 

notification is received, the port is inserted in the zone.

 

This policy takes precedence over all other policies. When this policy

 

is disabled, no additional policies are operational, and as long as a

 

port transmits a signal of the correct frequency and amplitude, the

 

port will be allowed in the zone.

 

 

Port Test Before Insertion

This policy ensures that a device on a port is a valid, standards-

 

compliant participant before allowing the device to be inserted into a

 

zone. The device must meet all of the FC-AL requirements along with

 

going through a complete change notification cycle. During the

 

change notification cycle, the device becomes the Initialization Master

 

(IM) and goes through the change notification phases. Once the

 

change notification cycle is complete, the device can be inserted. This

 

process ensures that a bad device is not allowed into the zone.

 

 

EMULEX CORPORATION

29

PART NUMBER 00041407-002 REV. B

Image 32
Contents Model ART N Umber 00041407-002 R EV. B Table of Contents Chapter Introduction OverviewFeatures Inspeed TechnologyInstallation Preparation To unpack the switchRack Installation Switch InstallationSwitch can be installed in a rack or placed on a desktop To install the switches in the trayUL Guidelines for Mounting Equipment in a Rack Desktop InstallationTo place the switch on a desktop Ethernet LEDs indicate the network connection status Switch LedsEthernet LEDs System LEDs Port LEDs SFP Status Port BypassedInstalling an SFP Attaching a Device to the SwitchRemoving an SFP SFP CompatibilityBooting the Switch and SAN To boot the switch and SANChapter Switch Management To connect through a serial interface Configuring the Network InterfaceGetting Started Connecting to the Web Manager Command Button Description SubmitCancel Web Manager OverviewCommand Button Description Reboot Login/LogoutDocumentation RefreshInitial Switch Setup Log in to the SwitchChange the Password To log in to the switchChange the Switch Name To view the current date and time Click Switch Date & TimeTo set the date and time settings To change the switch name Click Switch ConfigurationManaging the Switch Frequent Switch Configuration TasksLogging in to the Switch Configuring the Switch SettingsTo change a switch setting To reset the switchNetwork Location General Switch SettingsSwitch Identification Switch Speed To change the switch speed Click Switch ConfigurationVersion Information Blocking ARBSetting Snmp Traps To configure an Snmp trapTo synchronize time with the host system Click Host Time Configuring Date and Time SettingsTo change the time Click Switch Date & Time Opening a Telnet Session Changing the PasswordSwitch Password page appears To change switch thresholds or time intervals Adjusting the Switch ThresholdsSwitch Thresholds page appears Port Smart Settings page appears Configuring the Port Smart SettingsTo view the Port Smart Settings Click Port Smart Settings Default Smart Settings Creating Custom Smart Settings To assign a Smart Setting to one or more portsTo set all ports to the currently selected Smart Setting To create a custom Smart SettingSmart Setting Assignments To modify a custom Smart SettingTo rename a custom Smart Setting To delete a custom Smart SettingPort Information Pre-Insertion TestingFollowing settings are available Setting Description Stealth Intelligent Change Change NotificationsManager Change Notification onPort Recovery Managing Firmware and Configuration Files DiagnosticsSetting Description Port Control Bypass on Clock DeltaSwitch Firmware Files Switch Configuration FilesOne-Step Zoning Restoring the Factory Default SettingsTo restore the factory default configuration To add ports to a zone To activate zoningTo remove a port from a zone To remove all ports from a zoneSingle-Switch Zoning 13 Devices in a Single ZoneAdding Devices to Multiple Zones To add storage devices to multiple zonesMultiple Switch Zoning 17 Devices in Multiple Zones Across Multiple SwitchesRecovering a Bad Zone Automatically Alpa ZoningConnecting Ports Through Hard Zoning To set up Hard ZoningTree Cascades Cascading SwitchesString Cascades Automatic Trunking 22 Automatic Trunking exampleLoad Balancing 23 Advanced Functions Automatic TrunkingFairness and Prioritization Load IndicatorsTo change the load balancing settings Viewing Switch Status Monitoring the SwitchSwitch Information Current status is provided for the following itemsPort Utilization and Health Port Color Indication GreenYellow RedTo view the event log Click Switch Event Log Viewing the Event LogEvent Log Messages page appears Last time the event log was polled appears at the topPort Information page appears Viewing Port InformationTo view port information Click Port Information Viewing Port Utilization Port Utilization page appearsValue Description High AverageViewing Port Diagnostics Port Diagnostics page appearsTo save diagnostic information To reset a port Click Advanced Functions Diagnostics PortManual Port Operation To clear the countersViewing Ordered Sets CRC Error Detection Indication F7 InitializationChange Notification UnknownTroubleshooting Device Connections Troubleshooting Management Connections Port Bypass Conditions and RecoveryDefault Smart Setting Attributes Fibre Channel References Appendixes Switch Specifications Operating ConditionsConnecting to the CLI Logging in and OUTTo connect through a network interface To log in to the CLIUsing the CLI Frequent Switch Configuration TasksCLI Commands Severity Description Level Event Event Message SeverityError during Port Disc Port Ptbi failed due to timeoutInterswitch link added/removed LIP Cycle TimeoutArbitrated Loop Physical Addresses Hex DecimalAlpa or Arbitrated Loop Physical AddressArbitration Current Fill WordIndex SFP Part Number 00041407-002 REV. B