Other Operations

English

Other Operations

3Use the 5/buttons to select [MASK CONTROL].

MENU

 

 

INPUT1

PICTURE

SCREEN

SETUP

OPTION

LANGUAGE

 

: ENGLISH

ENERGY SAVE

 

: STANDARD

SCREEN MGT.

 

: OFF

ORBITER

 

: OFF

MASK CONTROL

 

: ON

AUTO SET UP MODE

: INACTIVE

AUTO FUNCTION

 

: OFF

AUDIO OUT

 

: FIXED

4Press the SET button to activate the setting. The factory default setting is [ON].

Each time the button is pressed, the setting alternates

as follows:

3 OFF

 

ON 2

5When finished with the setting, press the MENU button to return to the normal screen image.

Note

The [MASK CONTROL] setting affects all input sources.

Screen management settings (SCREEN MGT.)

In order to alleviate burning of lag images in the screen, this plasma display is equipped with a screen management program that allows automatic switching of the display image at regular intervals. The program can be set to determine how the 24-hour screen management cycle is repeated.

For information about detailed screen management settings, consult your professional installation technician.

MENU

 

5/

 

2/3

MENU

 

SET

2/3

 

Display

SET

5/

operating panel

Remote control unit

1Press the MENU button to display the menu

screen.

 

 

 

 

MENU

 

 

 

INPUT1

PICTURE

SCREEN

SETUP

OPTION

CONTRAST

 

:

0

 

BRIGHTNESS

:

0

 

COLOR

 

:

0

 

TINT

 

:

0

 

SHARPNESS

 

:

0

 

PICTURE RESET

 

 

 

2Use the 2/3 buttons to select [OPTION].

MENU

 

 

INPUT1

PICTURE

SCREEN

SETUP

OPTION

LANGUAGE

 

: ENGLISH

ENERGY SAVE

 

: STANDARD

SCREEN MGT.

 

: OFF

ORBITER

 

: OFF

MASK CONTROL

 

: ON

AUTO SET UP MODE

: INACTIVE

AUTO FUNCTION

 

: OFF

AUDIO OUT

 

: FIXED

3Use the 5/buttons to select [SCREEN MGT.], then press the SET button.

MENU

 

 

INPUT1

PICTURE

SCREEN

SETUP

OPTION

LANGUAGE

 

: ENGLISH

ENERGY SAVE

 

: STANDARD

SCREEN MGT.

 

: OFF

ORBITER

 

: OFF

MASK CONTROL

 

: ON

AUTO SET UP MODE

: INACTIVE

AUTO FUNCTION

 

: OFF

AUDIO OUT

 

: FIXED

4Use the 5/buttons to select [STATUS].

 

SCREEN MGT.

STATUS

:

OFF

TIME TO ACTIVATE :

01H00M

START

 

 

 

 

SET RETURN

MENU EXIT

5Use the 2/3 buttons to select [ONCE] or [REPEAT].

The factory default setting is [OFF].

Each time the button is pressed, the setting alternates

as follows:

3 OFF 2 3 ONCE 2

3REPEAT 2

÷ONCE ....... The screen management program is performed once only.

÷REPEAT .... The screen management program is performed repeatedly (24-hour cycle).

÷OFF .......... Screen management program is disabled, and normal screen image is displayed continuously.

32

En

Page 35
Image 35
Pioneer PDA-5004 manual Screen management settings Screen MGT, Other Operations Use the 5/∞ buttons to select Mask Control

PDA-5004, PDA-5003 specifications

The Pioneer PDA-5004 and PDA-5003 are innovative models in the realm of professional audio and multimedia processing, designed to meet the demands of both live sound and installed audio applications. These two products share many features and technologies, making them aligned in performance and capabilities while catering to slightly different user needs.

The PDA-5004 is equipped with a powerful four-channel amplifier that delivers 500 watts per channel at 4 ohms. This robust output ensures that users can have high-performance sound reinforcement for large venues or installations. In contrast, the PDA-5003 offers a three-channel design with an individual output of 500 watts per channel at 4 ohms, providing a slightly less complex setup while still offering ample power for many applications.

One of the key features of both models is their advanced digital signal processing (DSP) capabilities. This built-in DSP offers a range of features including equalization, crossover settings, and delay functions, allowing audio engineers to fine-tune sound to suit specific environments and preferences. Users can benefit from multiple pre-set configurations designed specifically for different types of audio experiences, from music playback to spoken word events, enhancing versatility.

The units also incorporate a variety of connectivity options, including XLR and RCA inputs, as well as outputs that facilitate integration with other audio devices and systems. They support both balanced and unbalanced connections, making them compatible with a wide range of audio sources. The inclusion of Ethernet connectivity on the PDA-5004 allows for remote control and monitoring via compatible software, offering enhanced convenience for professional users.

In terms of build quality, both amplifiers are designed with durability in mind, featuring a rugged chassis that can withstand the rigors of touring and installation environments. Additionally, their efficient cooling systems prevent overheating during prolonged use, ensuring reliability in demanding situations.

Overall, the Pioneer PDA-5004 and PDA-5003 represent a synthesis of cutting-edge technology and user-friendly features that make them well-suited for professionals seeking high-quality audio performance. With powerful amplification, advanced DSP capabilities, and versatile connectivity options, these models stand out as effective solutions for live sound and permanent installations alike.