Emulex 355 manual Using the CLI, Frequent Switch Configuration Tasks

Page 64

EMULEX MODEL 355 SAN STORAGE SWITCH

APPENDIX B: CLI QUICK REFERENCE

USERS GUIDE

USING THE CLI

The CLI enables users to monitor and change system and port configurations, configure One-Step Zoning, Automatic Trunking, Load Balancing, and event reporting parameters, and download and install firmware.

For additional information on the CLI, see the Emulex® or InSpeed™ Storage Switch Products’ CLI Reference Guide.

To enter a command:

Type the command text or the number of the command.

To return to the previous menu:

Type .. and press ENTER.

To return directly to the Root menu:

Type root and press ENTER.

To cancel a prompt or input request:

Press ENTER.

To display help for specific command:

Type ? <command> and press ENTER.

To save changes to the switch configuration at any time:

1.Type save at any command prompt and press ENTER. A message appears confirming the request.

2.Type y and press ENTER.

FREQUENT SWITCH CONFIGURATION TASKS

A list of frequent switch configuration-related tasks is provided below. The list displays the task and the corresponding CLI command.

To…

Type…

 

 

View switch status

show sysinfo

 

 

Change general switch configuration

config sys

 

 

Change the IP Address

config network ip

 

 

Change the switch speed

config sys speed

 

 

View the event log

show events

 

 

Upgrade the firmware

fw

 

 

Change the port settings

config port

 

 

Configure zoning

config zone

 

 

Configure trunking

config load

 

 

Configure load balancing

config trunk

 

 

Reset the switch

reset

 

 

Perform diagnostics

diag

 

 

Reset the switch to factory default settings

config default

 

 

Change the password

config password

 

 

EMULEX CORPORATION

61

PART NUMBER 00041407-002 REV. B

Image 64
Contents Model ART N Umber 00041407-002 R EV. B Table of Contents Chapter Introduction OverviewFeatures Inspeed TechnologyInstallation Preparation To unpack the switchRack Installation Switch InstallationSwitch can be installed in a rack or placed on a desktop To install the switches in the trayTo place the switch on a desktop Desktop InstallationUL Guidelines for Mounting Equipment in a Rack Ethernet LEDs Switch LedsEthernet LEDs indicate the network connection status System LEDs Port LEDs SFP Status Port BypassedInstalling an SFP Attaching a Device to the SwitchRemoving an SFP SFP CompatibilityBooting the Switch and SAN To boot the switch and SANChapter Switch Management Getting Started Configuring the Network InterfaceTo connect through a serial interface Connecting to the Web Manager Command Button Description SubmitCancel Web Manager OverviewCommand Button Description Reboot Login/LogoutDocumentation RefreshInitial Switch Setup Log in to the SwitchChange the Password To log in to the switchChange the Switch Name To view the current date and time Click Switch Date & TimeTo set the date and time settings To change the switch name Click Switch ConfigurationManaging the Switch Frequent Switch Configuration TasksLogging in to the Switch Configuring the Switch SettingsTo change a switch setting To reset the switchSwitch Identification General Switch SettingsNetwork Location Switch Speed To change the switch speed Click Switch ConfigurationVersion Information Blocking ARBSetting Snmp Traps To configure an Snmp trapTo change the time Click Switch Date & Time Configuring Date and Time SettingsTo synchronize time with the host system Click Host Time Switch Password page appears Changing the PasswordOpening a Telnet Session Switch Thresholds page appears Adjusting the Switch ThresholdsTo change switch thresholds or time intervals To view the Port Smart Settings Click Port Smart Settings Configuring the Port Smart SettingsPort Smart Settings page appears Default Smart Settings Creating Custom Smart Settings To assign a Smart Setting to one or more portsTo set all ports to the currently selected Smart Setting To create a custom Smart SettingSmart Setting Assignments To modify a custom Smart SettingTo rename a custom Smart Setting To delete a custom Smart SettingFollowing settings are available Pre-Insertion TestingPort Information Setting Description Stealth Intelligent Change Change NotificationsManager Change Notification onPort Recovery Managing Firmware and Configuration Files DiagnosticsSetting Description Port Control Bypass on Clock DeltaSwitch Firmware Files Switch Configuration FilesTo restore the factory default configuration Restoring the Factory Default SettingsOne-Step Zoning To add ports to a zone To activate zoningTo remove a port from a zone To remove all ports from a zoneSingle-Switch Zoning 13 Devices in a Single ZoneAdding Devices to Multiple Zones To add storage devices to multiple zonesMultiple Switch Zoning 17 Devices in Multiple Zones Across Multiple SwitchesRecovering a Bad Zone Automatically Alpa ZoningConnecting Ports Through Hard Zoning To set up Hard ZoningString Cascades Cascading SwitchesTree Cascades Automatic Trunking 22 Automatic Trunking exampleLoad Balancing 23 Advanced Functions Automatic TrunkingTo change the load balancing settings Load IndicatorsFairness and Prioritization Viewing Switch Status Monitoring the SwitchSwitch Information Current status is provided for the following itemsPort Utilization and Health Port Color Indication GreenYellow RedTo view the event log Click Switch Event Log Viewing the Event LogEvent Log Messages page appears Last time the event log was polled appears at the topTo view port information Click Port Information Viewing Port InformationPort Information page appears Viewing Port Utilization Port Utilization page appearsValue Description High AverageViewing Port Diagnostics Port Diagnostics page appearsTo save diagnostic information To reset a port Click Advanced Functions Diagnostics PortManual Port Operation To clear the countersViewing Ordered Sets CRC Error Detection Indication F7 InitializationChange Notification UnknownTroubleshooting Device Connections Troubleshooting Management Connections Port Bypass Conditions and RecoveryDefault Smart Setting Attributes Fibre Channel References Appendixes Switch Specifications Operating ConditionsConnecting to the CLI Logging in and OUTTo connect through a network interface To log in to the CLIUsing the CLI Frequent Switch Configuration TasksCLI Commands Severity Description Level Event Event Message SeverityError during Port Disc Port Ptbi failed due to timeoutInterswitch link added/removed LIP Cycle TimeoutArbitrated Loop Physical Addresses Hex DecimalAlpa or Arbitrated Loop Physical AddressArbitration Current Fill WordIndex SFP Part Number 00041407-002 REV. B
Related manuals
Manual 74 pages 23.77 Kb

355 specifications

The Emulex 355 is a high-performance network interface card (NIC) designed specifically for data centers requiring advanced connectivity, reliability, and speed. With the rapid evolution of data transmission technology, the Emulex 355 stands out due to its robust features and capabilities that cater to the demands of modern IT infrastructures.

One of the key features of the Emulex 355 is its support for 10 Gigabit Ethernet, which allows for significantly faster data transfer rates compared to standard Gigabit connections. This increased bandwidth is essential for handling large volumes of data traffic, particularly in virtualized environments and cloud computing applications. Its high throughput ensures that data can be transmitted rapidly across networks, minimizing latency and improving overall performance.

The Emulex 355 employs advanced technologies such as iSCSI Offload and FCoE (Fibre Channel over Ethernet), which help enhance data processing efficiency. These technologies allow the card to offload processing tasks from the host system's CPU, reducing the load on server resources and optimizing performance. The result is a more efficient system that can handle more concurrent connections and processes without being overwhelmed.

In addition to speed and efficiency, reliability is paramount in data center operations. The Emulex 355 includes features like error detection and correction, ensuring data integrity during transmission. Built-in redundancy and failover capabilities safeguard against potential network disruptions, allowing for continuous availability of services—a crucial aspect in mission-critical environments.

The Emulex 355 also offers support for various robust networking protocols, enabling seamless integration into existing network infrastructures. Its compatibility with multiple operating systems and virtualization platforms, such as VMware and Microsoft Hyper-V, further enhances its versatility.

Another notable characteristic of the Emulex 355 is its energy-efficient design. It is optimized for lower power consumption without sacrificing performance, aligning with contemporary efforts to reduce the carbon footprint in data centers.

In conclusion, the Emulex 355 NIC is a powerful solution equipped with features that address the complex demands of modern data centers. Its combination of speed, reliability, and efficiency, along with advanced technologies, makes it a preferred choice for organizations looking to enhance their network capabilities and ensure smooth, uninterrupted operations.