Emulex 355 manual Viewing Port Information, To view port information Click Port Information

Page 51

EMULEX MODEL 355 SAN STORAGE SWITCH

CHAPTER 3: SWITCH MANAGEMENT

USERS GUIDE

Viewing Port Information

The Port Information page displays the Smart Settings, Serial ID (SID), and AL_PAs currently assigned to each port. Initiator AL_PAs are highlighted in blue to differentiate them from target AL_PAs.

Note: The Initiator AL_PA information can be used to easily identify attached devices when configuring load balancing.

To view port information:

Click Port > Information.

The Port Information page appears.

Figure 3-28: Port Information page

Field

Description

 

 

Port

Displays the current health of the port. See “Port Utilization and

 

Health” on page 46 for additional information on port health.

 

 

Smart Setting

Displays the specific Smart Setting assigned to a particular port. See

 

“Configuring the Port Smart Settings” on page 25 for more information

 

on the Smart Settings.

 

 

Serial ID (SID)

When clicked, provides additional information about the SFP inserted

 

in the port, if an SFP is inserted in that particular port.

 

 

Identified ALPAs

Displays all the AL_PAs attached to the port. Initiator AL_PAs appear

 

highlighted in blue.

 

 

EMULEX CORPORATION

48

PART NUMBER 00041407-002 REV. B

Image 51
Contents Model ART N Umber 00041407-002 R EV. B Table of Contents Overview Chapter IntroductionInspeed Technology FeaturesTo unpack the switch Installation PreparationTo install the switches in the tray Rack InstallationSwitch Installation Switch can be installed in a rack or placed on a desktopDesktop Installation To place the switch on a desktopUL Guidelines for Mounting Equipment in a Rack Switch Leds Ethernet LEDsEthernet LEDs indicate the network connection status System LEDs SFP Status Port Bypassed Port LEDsSFP Compatibility Installing an SFPAttaching a Device to the Switch Removing an SFPTo boot the switch and SAN Booting the Switch and SANChapter Switch Management Configuring the Network Interface Getting StartedTo connect through a serial interface Web Manager Overview Connecting to the Web ManagerCommand Button Description Submit CancelRefresh Command Button Description RebootLogin/Logout DocumentationTo log in to the switch Initial Switch SetupLog in to the Switch Change the PasswordTo change the switch name Click Switch Configuration Change the Switch NameTo view the current date and time Click Switch Date & Time To set the date and time settingsFrequent Switch Configuration Tasks Managing the SwitchTo reset the switch Logging in to the SwitchConfiguring the Switch Settings To change a switch settingGeneral Switch Settings Switch IdentificationNetwork Location Blocking ARB Switch SpeedTo change the switch speed Click Switch Configuration Version InformationTo configure an Snmp trap Setting Snmp TrapsConfiguring Date and Time Settings To change the time Click Switch Date & TimeTo synchronize time with the host system Click Host Time Changing the Password Switch Password page appearsOpening a Telnet Session Adjusting the Switch Thresholds Switch Thresholds page appearsTo change switch thresholds or time intervals Configuring the Port Smart Settings To view the Port Smart Settings Click Port Smart SettingsPort Smart Settings page appears Default Smart Settings To create a custom Smart Setting Creating Custom Smart SettingsTo assign a Smart Setting to one or more ports To set all ports to the currently selected Smart SettingTo delete a custom Smart Setting Smart Setting AssignmentsTo modify a custom Smart Setting To rename a custom Smart SettingPre-Insertion Testing Following settings are availablePort Information Change Notification on Setting Description Stealth Intelligent ChangeChange Notifications ManagerPort Recovery Bypass on Clock Delta Managing Firmware and Configuration FilesDiagnostics Setting Description Port ControlSwitch Configuration Files Switch Firmware FilesRestoring the Factory Default Settings To restore the factory default configurationOne-Step Zoning To remove all ports from a zone To add ports to a zoneTo activate zoning To remove a port from a zone13 Devices in a Single Zone Single-Switch ZoningTo add storage devices to multiple zones Adding Devices to Multiple Zones17 Devices in Multiple Zones Across Multiple Switches Multiple Switch ZoningAlpa Zoning Recovering a Bad Zone AutomaticallyTo set up Hard Zoning Connecting Ports Through Hard ZoningCascading Switches String CascadesTree Cascades 22 Automatic Trunking example Automatic Trunking23 Advanced Functions Automatic Trunking Load BalancingLoad Indicators To change the load balancing settingsFairness and Prioritization Current status is provided for the following items Viewing Switch StatusMonitoring the Switch Switch InformationRed Port Utilization and HealthPort Color Indication Green YellowLast time the event log was polled appears at the top To view the event log Click Switch Event LogViewing the Event Log Event Log Messages page appearsViewing Port Information To view port information Click Port InformationPort Information page appears Average Viewing Port UtilizationPort Utilization page appears Value Description HighPort Diagnostics page appears Viewing Port DiagnosticsTo clear the counters To save diagnostic informationTo reset a port Click Advanced Functions Diagnostics Port Manual Port OperationViewing Ordered Sets Notification Unknown CRC ErrorDetection Indication F7 Initialization ChangeTroubleshooting Device Connections Port Bypass Conditions and Recovery Troubleshooting Management ConnectionsDefault Smart Setting Attributes Fibre Channel References Appendixes Operating Conditions Switch SpecificationsTo log in to the CLI Connecting to the CLILogging in and OUT To connect through a network interfaceFrequent Switch Configuration Tasks Using the CLICLI Commands Event Event Message Severity Severity Description LevelLIP Cycle Timeout Error during Port DiscPort Ptbi failed due to timeout Interswitch link added/removedHex Decimal Arbitrated Loop Physical AddressesCurrent Fill Word Alpa or Arbitrated LoopPhysical Address ArbitrationIndex SFP Part Number 00041407-002 REV. B
Related manuals
Manual 74 pages 23.77 Kb

355 specifications

The Emulex 355 is a high-performance network interface card (NIC) designed specifically for data centers requiring advanced connectivity, reliability, and speed. With the rapid evolution of data transmission technology, the Emulex 355 stands out due to its robust features and capabilities that cater to the demands of modern IT infrastructures.

One of the key features of the Emulex 355 is its support for 10 Gigabit Ethernet, which allows for significantly faster data transfer rates compared to standard Gigabit connections. This increased bandwidth is essential for handling large volumes of data traffic, particularly in virtualized environments and cloud computing applications. Its high throughput ensures that data can be transmitted rapidly across networks, minimizing latency and improving overall performance.

The Emulex 355 employs advanced technologies such as iSCSI Offload and FCoE (Fibre Channel over Ethernet), which help enhance data processing efficiency. These technologies allow the card to offload processing tasks from the host system's CPU, reducing the load on server resources and optimizing performance. The result is a more efficient system that can handle more concurrent connections and processes without being overwhelmed.

In addition to speed and efficiency, reliability is paramount in data center operations. The Emulex 355 includes features like error detection and correction, ensuring data integrity during transmission. Built-in redundancy and failover capabilities safeguard against potential network disruptions, allowing for continuous availability of services—a crucial aspect in mission-critical environments.

The Emulex 355 also offers support for various robust networking protocols, enabling seamless integration into existing network infrastructures. Its compatibility with multiple operating systems and virtualization platforms, such as VMware and Microsoft Hyper-V, further enhances its versatility.

Another notable characteristic of the Emulex 355 is its energy-efficient design. It is optimized for lower power consumption without sacrificing performance, aligning with contemporary efforts to reduce the carbon footprint in data centers.

In conclusion, the Emulex 355 NIC is a powerful solution equipped with features that address the complex demands of modern data centers. Its combination of speed, reliability, and efficiency, along with advanced technologies, makes it a preferred choice for organizations looking to enhance their network capabilities and ensure smooth, uninterrupted operations.