1 - SAFETY CONSIDERATIONS

1.1 - General

Installation, start-up and servicing of equipment can be hazard- ous if factors particular to the installation are not considered: operating pressures, electrical components, voltages and the installation site itself (elevated plinths, rooftops and built-up structures).

Only highly trained and qualified installation engineers and technicians, who are fully trained on the product, are authorised to install and start up this equipment.

During all servicing operations, it is important to read, under- stand and follow all the recommendations and instructions given in the installation and service instructions for the product, including the tags and labels affixed to the equipment, compo- nents and any parts supplied separately, and to comply with all other relevant safety regulations.

Apply all safety codes and practices.

Wear safety glasses and gloves.

Use the proper tools to move heavy objects. Move units carefully and set them down gently.

1.2 - Avoiding electrocution

Only personnel qualified in accordance with the recommendat- ions of the IEC (International Electrotechnical Commission) may be permitted access to electrical components. It is parti- cularly recommended that all sources of electricity to the unit be shut off before any work is begun. Shut off the main power supply at the main circuit breaker or isolator.

IMPORTANT:

Risk of electrocution: Even when the main power isolator or circuit breaker is off, it is still possible for certain compo- nents such as crankcase heaters and trace heaters to be energised, since they are connected to a separate power source.

Even when the unit is switched off, the power circuit remains energised, as long as the unit or circuit disconnect is not open. Refer to the wiring diagram for details.

Attach appropriate safety labels.

Risk of burns: Electrical currents cause components to get hot either temporarily or permanently. Handle power cables, electrical cables and conduits, terminal box covers and motor frames with very great care.

IMPORTANT: This equipment uses and emits electromagnetic signals. The tests carried out on this product have shown that it complies with all applicable codes regarding electromagnetic compatibility.

IMPORTANT : If the boards need to be handled wear anti- static gloves to avoid exposing the electronic components to a destructive voltage. Only unpack the boards from their anti- static bag when they need to be installed.

4

Image 4
Contents Installation, operation and maintenance instructions 30GK Series PRO-DIALOG ControlTable of Contents Safety Considerations Diagnostics Troubleshooting General Safety ConsiderationsAvoiding electrocution General Description Abbreviations usedHardware Description General Control boardElectronic boards Control boxBoard addresses Red LEDGreen LED Orange LED CCN/clock boardEvaporator entering water temperature sensor Evaporator leaving water temperature sensorCondenser entering and leaving water temperature sensors Heat reclaim condenser entering/leaving water temperaturesDescription Connector Terminal Channel User connectionsAvailable Terminals RemarksSetting UP PRO-DIALOG Plus Control Local interface general featuresMain interface Main Interface Button Name DescriptionStopping the unit in local mode Unit start/stop controlDescription Starting unit and selecting an operating typeModifying the value of a parameter/access to a sub- menu MenusSelecting a menu Selecting a menu itemMenu StructureMenu tree StatusDescription of the Information menu Information Menu Format Units DescriptionDescription of the Temperatures menu Temperatures Menu Format Units CommentsDescription of the Pressures menu Pressures Menu Format Units CommentsDescription of the Setpoints menu Setpoints Menu Format Units Range CommentsDescription of the Inputs menu Description of the Outputs/Tests menu GeneralMenu description Inputs Menu Format Units CommentsFormat Units Description Password Description of the Configuration menu GeneralManual tests SUB-MENU Period Configuration SUB-MENU Holiday ConfigurationDescription of the User 1 Configuration sub-menu User 1 Configuration SUB-MENU Format Units Default CommentsDescription of Date and Time configuration sub Menu Description of the User 2 Configuration sub-menuDate & Time Configuration SUB-MENU Format Comments Typical timer program Description of the Holidays sub-menusDescription of the Broadcast sub-menu Item # Format CommentsDescription of the Alarms menu Description of the Alarms History menuBroadcast Configuration SUB-MENU Item # Format Comments Alarms Menu Item # Format DescriptionRuntime menu description Description of the Runtimes 2 menu Maintenance menu descriptionDescription of the Runtimes 1 menu Chilss Contact Type Mode Shutdown PRO-DIALOG Plus Control OperationStart/stop control Heating/cooling selectionEvaporator water pump control Control interlock contact Condenser water pump controlEvaporator heater control Control pointDemand limit by 0-10 V d.c. signal Demand limitCapacity control Determining the lead circuitSlave compressor start-up sequence Controlling the EXVHead pressure control on air-cooled units Head pressure control on water-cooled unitsMaster/slave assembly High pressure load shedding functionPumping down Controlling Pro-Dialog Plus units with a System ManagerDiagnostics Troubleshooting Displaying alarmsResetting alarms Optional heat reclaim moduleAlarm codes Alarm Code DescriptionsCCN Compressor faults 6.4.1.1 General DGT only for units with low-temperature optionCompressor protection devices Starter Guard

30GK specifications

The Carrier 30GK is a prominent chiller model known for its efficiency and reliability in various commercial and industrial applications. Offering a blend of advanced technology and robust design, the 30GK series caters to diverse cooling needs while maintaining energy efficiency and low operational costs.

One of the standout features of the 30GK is its use of the latest scroll compressor technology. This contributes to its efficient performance, enabling the chiller to operate at optimal levels while minimizing energy consumption. The scroll compressor is known for its quiet operation, which reduces noise pollution, making it an ideal choice for buildings located in noise-sensitive environments.

The 30GK chiller series is equipped with microchannel coil technology, which allows for improved heat exchange efficiency. The microchannel design uses a compact coil structure that enhances refrigerant flow and reduces refrigerant volume, leading to a smaller footprint compared to traditional coil designs. This innovative design not only saves space but also improves the chiller's overall performance.

Another notable characteristic of the Carrier 30GK is its environmental consciousness. The chiller operates using environmentally friendly refrigerants, aligning with modern regulations and sustainability goals. Its design incorporates energy-efficient components that contribute to significant reductions in greenhouse gas emissions, making it suitable for environmentally responsible projects.

Moreover, the 30GK is designed for easy serviceability, with accessible components that simplify maintenance. This feature is particularly important for facility managers seeking to minimize downtime and keep maintenance costs low. The chiller also includes advanced monitoring and control systems, which enable real-time performance tracking and diagnostics, enhancing operational efficiency.

In terms of performance, the 30GK chiller is known for its wide capacity range, making it versatile for various applications. Whether for commercial spaces, industrial processes, or large buildings, the 30GK can meet the cooling demands reliably.

Overall, the Carrier 30GK chiller represents a perfect balance of cutting-edge technology, energy efficiency, and sustainability. Its features make it a leading choice in the market, suited for those looking to invest in high-quality and dependable cooling solutions.