Ferguson JWSH100150, JWSH100250 warranty Table of Contents, Features

Page 3

TABLE OF CONTENTS

PAGE

 

ROUGH-IN DIMENSIONS

2

FOREWORD

2

FEATURES

3,4

Water Temperature Control

3

High Limit Switch (E.C.O.)

4

Dishwashing Machine Requirement

4

Circulating Pump

5

INSTALLATION INSTRUCTIONS

4

Required Ability

4

Insulation Blankets

4

Locating The Heater

5

Clearances

5

Hard Water

6

Air Requirements

6

Mechanical Exhausting of Room Air

6

Unconfined Space

6

Confined Space

6

Chemical Vapor Corrosion

6

Venting

6

Vent Pipe Termination

6

Installation Requirements for the

 

Direct Venting

8

Direct Vent Terminal Installation (Sidewall)

8

Vertical Vent Terminal Installation

9

Installation Sequence

9

Installation of Vent System

10

Vent Pipe Preparation

10

Control and Switches

11

Blower Prover Switch

11

Blocked Outlet Prover Switch

11

Blocked Inlet Prover Switch

11

Low Gas Pressure Switch

11

On/Off Switch

11

Hot Surface Igniter

11

GAS PIPING

11

Connection of Gas Pipe

12

Purging

13

Gas Meter Size - City Gases Only

13

Gas Pressure Regulation

13

Gas Valves

13

SYSTEM CONNECTIONS

13

PAGE

 

Thermometers

13

Relief Valve

13

Water Line Connections

13

Heater Wiring

14

USING THE ELECTRONIC CONTROLLER

15

Overview

15

Operating States

15

Adjusting the Operating Set Point

16

Changing the Display Units

17

Fault and Warning Conditions

17

Access to the Current Fault or Warning

17

Viewing the Fault History

18

PRIOR TO START-UP

18

Required Ability

18

OPERATING INSTRUCTIONS

19

Adjustment Procedure (Initial Start-Up) 120 and 150 Models

19

Adjustment Procedure (Initial Start-Up) 199 and 250 Models

19

Cathodic Protection

20

Precautions

20

GENERAL INFORMATION

20

Power Burner

20

High Limit

20

High Altitude Installations

20

MAINTENANCE

20

General

20

Maintenance Schedule

20

Flushing

23

Draining

23

Sediment Removal

23

Lime Scale Removal

23

Anode Inspection and Replacement

23,24

Drain Valve and Access Panels

24

Relief Valve

24

Circulating Pump

24

Vent System

24

INSTALLATION DIAGRAMS

25-29

Manifold Kits

30

CHECKLIST AND SERVICE INFORMATION

31

TROUBLE-SHOOTING

31

LIMITED WARRANTY

33

FEATURES

IMPORTANT

IT IS REQUIRED THAT A QUALIFIED SERVICE TECHNICIAN PERFORM THE INITIAL FIRING OF THE HEATER. AT THIS TIME THE USER SHOULD NOT HESITATE TO ASK THE TECHNICIAN ANY QUESTIONS WHICH HE MAY HAVE IN REGARD TO THE OPERATION AND MAINTENANCE OF THE UNIT.

A CHECKLIST AND SERVICE INFORMATION section are included at the rear of this manual. By using this checklist the user may be able to make minor operational adjustments and save himself unnecessary service calls. However, the user should not attempt repairs which are not listed in this section.

WATER TEMPERATURE CONTROL

DANGER

THIS WATER HEATER IS EQUIPPED WITH AN ADJUSTABLE THERMOSTAT TO CONTROL WATER TEMPERATURE. HOT WATER TEMPERATURES REQUIRED FOR AUTOMATIC DISHWASHER AND LAUNDRY USE CAN CAUSE SCALD BURNS RESULTING IN SERIOUS PERSONAL INJURY AND/OR DEATH. THE TEMPERATURE AT WHICH INJURY OCCURS VARIES WITH THE PERSON’S AGE AND THE TIME OF THE EXPOSURE. THE SLOWER RESPONSE TIME OF CHILDREN, AGED OR DISABLED PERSONS INCREASES THE HAZARDS TO THEM. NEVER ALLOW SMALL CHILDREN TO USE A HOT WATER TAP, OR TO DRAW THEIR OWN BATH WATER. NEVER LEAVE A CHILD OR DISABLED PERSON UNATTENDED IN A BATHTUB OR SHOWER.

THE WATER HEATER SHOULD BE LOCATED IN AN AREA WHERE THE GENERAL PUBLIC DOES NOT HAVE ACCESS TO SET TEMPERATURES.

The water temperature is controlled using the Temperature Control Button on the Display at the front of the unit (See Figure 1). This control utilizes two temperature probes to determine the tank temperature. The primary temperature probe is located at the top of the tank and the other is near the water inlet.

The temperature may be adjusted from 90°F/32°C to 180°F/82°C. The thermostat was adjusted to 120°F/49°C before the heater was shipped from the factory. It is recommended that lower water temperature be used to avoid the risk of scalding. It is further recommended, in all cases, that the water

3

Image 3
Contents Printed Models AJWSH100150 Thru AJWSH100250Foreword Models AJWSH100150 Thru AJWSH100250 ROUGH-IN-DIMENSIONSFeatures Table of ContentsInstallation Instructions Clearances Locating the HeaterUnconfined Space Hard WaterAIR Requirements Mechanical Exhausting of Room AIRCanadian Power Vent Canadian Direct Vent Wooden Side Walls Direct Vent Terminal InstallationDirect Venting Masonry Side WallsInstallation Sequence Vertical Vent Terminal InstallationSelection of Materials Installation of Vent SystemVent Pipe Preparation Initial PreparationGAS Piping Controls and SwitchesAJWSH100199 & AJWSH100250 Models Only Connection of GAS PipeSystem Connections Heater Wiring Overview Using the Electronic ControllerOperating States Changing the Display Units Prior to Start UP Viewing the Fault HistoryOperating Instructions Adjustment ProcedureGeneral Information MaintenanceAJWSH100150 only AJWSH100199 & AJWSH100250 Models only Sediment Removal Powered Anode SystemFlushing DrainingVent System Drain Valve and Access PanelsInstallation Diagrams Page Must be Identical Heaters Page Page Manifold Kits TROUBLE-SHOOTING Checklist and Service InformationGAS Fails to Shut OFF Replacement PartsMotor will not RUN Motor RUNS, Burner Lights Momentarily Then Locks OUTModels AJWSH100150 thru AJWSH100250 Limited Warranty Page Page Hill Street West Fergus, on Canada N1M