Horizontal Vent Terminal Location
The following information should be used for determining the proper location of the vent terminal for indoor and outdoor tankless water heaters.
|
| Canadian Installations 1 | US Installations 2 | US Installations 2 |
|
| Indoor and Outdoor | Indoor | Outdoor |
|
|
|
|
|
A= | Clearance above grade, veranda, | 12 inches (30 cm) above anticipated | 12 inches (30 cm) above anticipated | 12 inches (30 cm) above anticipated |
| porch, deck or balcony. | |||
| snow level. | snow level. | snow level. | |
|
| |||
|
|
|
|
|
B= | Clearance to window or door that | 6 inches (15 cm) for appliances < 10,000 |
| 6 inches (15 cm) for appliances < |
| may be opened. |
| 10,000 Btuh (3 kW), 9 inches (23 cm) | |
| Btuh (3 kW), 12 inches (30 cm) for | 4 feet (1.2 m) below or to side of | ||
|
| for appliances > 10,000 Btuh (3kW) | ||
|
| appliances > 10,000 Btuh (3kW) and < | opening; 1 foot (300 mm) above | |
|
| and < 50,000 Btuh (15kW), 12 inches | ||
|
| 100,000 Btuh (30kW), 36 inches (91 cm) | opening. | |
|
| (30 cm) for appliances > 50,000 Btuh | ||
|
| for appliances > 100,000 Btuh (30kW). |
| |
|
|
| (15kW). | |
|
|
|
| |
|
|
|
|
|
C= | Clearance to permanently closed | * | * | * |
| window. | |||
|
|
|
| |
|
|
|
|
|
D= | Vertical Clearance to ventilated |
|
|
|
| soffit located above the terminal |
|
|
|
| within a horizontal distance of 2 | * | * | * |
| feet (61 cm) from the center line |
|
|
|
| of the terminal. |
|
|
|
|
|
|
|
|
E= | Clearance to unventilated soffit. | * | * | * |
|
| |||
|
|
|
|
|
F= | Clearance to outside corner. | * | * | * |
|
| |||
|
|
|
|
|
G= | Clearance to corner. | * | * | * |
|
|
|
| |
H = Clearance to each side of center | 3 feet (91 cm) within a height 15 feet |
|
| |
| line extended meter/regulator | * |
| |
| (4.57 m) above the meter/regulator | * | ||
| assembly. above | |||
| assembly. |
|
| |
|
|
|
| |
|
|
|
|
|
I = | Clearance to service regulator vent | 3 feet (91 cm) | * | * |
| outlet. | |||
|
|
|
| |
|
|
|
|
|
J = | Clearance to nonmechanical air | 6 inches (15 cm) for appliances < |
| 6 inches (15 cm) for appliances < 10,000 |
| supply inlet to the combustion air | 10,000 Btuh (3 kW), 12 inches (30 cm) |
| |
| 4 feet (1.2 m) below or to side of | Btuh (3 kW), 9 inches (23 cm) for | ||
| inlet to any building or other | for appliances > 10,000 Btuh (3kW) | ||
| opening; 1 foot (300 mm) above | appliances > 10,000 Btuh (3kW) and < | ||
| appliance. | and < 100,000 Btuh (30kW), 36 inches | ||
| opening. | 50,000 Btuh (15kW), 12 inches (30 cm) | ||
|
| (91 cm) for appliances > 100,000 Btuh | ||
|
|
| for appliances > 50,000 Btuh (15kW). | |
|
| (30kW). |
| |
|
|
|
| |
|
|
|
|
|
K = | Clearance to mechanical air | 6 feet (1.83 m) | 3 feet (91 cm) above if within 10 feet | 3 feet (91 cm) above if within 10 feet |
| supply inlet. | (3 m) horizontally. | (3 m) horizontally. | |
|
| |||
|
|
|
|
|
L = | Clearance above paved sidewalk |
|
|
|
| or paved driveway located on | Not Allowed | Not Allowed | Not Allowed |
| public property. |
|
|
|
|
|
|
| |
M = Clearance under veranda, porch, | Not Allowed | Not Allowed | Not Allowed | |
| deck or balcony. | |||
|
|
|
| |
|
|
|
|
|
*If clearances are not specified, then follow local installation codes and the requirement of the gas supplier.
| ** For condensing appliances: The vent for this appliance shall not terminate over public walkways, near soffit vents, crawl space vents, or other |
| areas where condensate or vapor could create a nuisance, hazard or cause property damage, or where condensate or vapor could cause damage |
12 | or could be detrimental to the operation of regulators, relief valves or other equipment. |
|