Rheem RMTG2-53-(PVN)(PVP)(XN)(XP), PTG2-42(PVN)(PVP) Temperature Setting DIP Switch Adjustment

Page 35

The content on this page is intended for use by qualified

installation/service personnel ONLY.

WARNING: Improper adjustment, alteration,

! DANGER: Hotter water increases

service or maintenance can cause property damage,

the potential for Hot Water SCALDS.

personal injury, or death.

 

Temperature Setting DIP Switch Adjustment

Required adjustment for up to 140°F (60°C) water temperature settings

!WARNING: Refer to scald potential warnings on page 4 before making adjustment. Changing this setting is done at your own risk.

DO NOT alter the #4 DIP Switch if the setting of up to 140°F (60°C) is not required.

Follow the instructions below if it is determined that a setting of up to 140°F (60°C) is required.

Turn off remote control. Turn off the gas and water shutoff valves.

Remove the front cover.

Find the DIP Switch #4 located at the top left hand side of the PCB. (See diagram to the right for DIP Switch location).

Change the DIP Switch #4 setting to the “ON” position. DO NOT alter any other DIP Switch. The LED on the PCB is flashing. At the same time, the display of the Main Remote Control starts to flash.

Press the “SW1” button on the left hand side of the PCB for more than 1 second. The LED on the PCB starts illuminating continuously. At the same time, the display of the Main Remote Control is on continuously.

Change the DIP Switch #4 setting back to the “OFF” position. DO NOT alter any other DIP Switch. The LED on the PCB will stop illuminating. At the same time, the display of the Main Remote Control will turn off.

Time/Temperature Relationship in Scalds

Water Temperature

 

 

 

Time To Produce a Serious Burn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120°F (49°C)

 

 

 

 

 

 

 

 

 

More than 5 minutes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

125°F (52°C)

 

 

 

 

 

 

 

 

 

 

1-1/2 to 2 minutes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

130°F (54°C)

 

 

 

 

 

 

 

 

 

 

About 30 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

135°F (57°C)

 

 

 

 

 

 

 

 

 

 

About 10 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

140°F (60°C)

 

 

 

 

 

 

 

 

 

 

Less than 5 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

145°F (63°C)

 

 

 

 

 

 

 

 

 

 

Less than 3 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150°F (66°C)

 

 

 

 

 

 

 

 

 

About 1-1/2 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

155°F (68°C)

 

 

 

 

 

 

 

 

 

 

About 1 second

 

 

 

 

 

 

 

 

 

 

Table courtesy of Shriners Burn Institute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

DIP1

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

4

 

 

OFF

 

 

 

 

 

 

 

 

 

1

2

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attach the unit’s front cover.

Turn on the remote control, gas and water shutoff valves.

Check and ensure safe operation and performance of the water heater.

See steps below to LIMIT maximum water temperature setting to 120°F (49°C).

Location of DIP Switches on PC Board.

ON

1 2 3 4

Follow first four bullets points listed above, then continue as listed below:

Press the “SW2” button on the left hand side of the PCB for more than 1 second. The LED on the PCB starts illuminating continuously. At the same time, the display of the Main Remote Control is on continuously.

Change the DIP Switch #4 setting back to the “OFF” position. DO NOT alter any other DIP Switch. The LED on the PCB will stop flashing.

At the same time, the display of the Main Remote Control will turn off.

Attach the unit’s front cover.

Turn on the remote control, gas and water shutoff valves.

Check and ensure safe operation and performance of the water heater.

As set from factory

ON

1 2 3 4

Setting during adjustment

to DIP Switch #4 for temperature.

ON

1 2 3 4

Setting after adjustment

to DIP Switch #4

“SW2”

for temperature.

ButtonLED

“SW1” Button

DIP

Switches

35

Image 35
Contents Defects or other reproductive harm Tankless Water HeaterInjury You can find them on a label on the applianceThat will result in death or serious Install and Properly Vent the Water HEATER… N G E R Natural GAS and Liquefied Petroleum Models Read and Follow this Safety Information Carefully Location of the Outdoor water heater Installing the Outdoor water heaterLocation of Indoor Water Heater Installing the Indoor water heaterInspect Shipment Installing the water heaterCombustion and Ventilation Air Indoor Water Heater Only Corrosive AtmospheresMinimum Vent Length The venting VentingVenting Lengths Maximum Vent LengthDraining the Condensate Venting Through Closed SpacesAppliance Vent Adapter Horizontal Vent Terminal Location Canadian InstallationsAdditional Considerations Indoor Water HeaterVent Horizontal Wall Thimble Installation Vertical Vent Termination Location Vertical Vent InstallationWater Supply Connections Mounting the Water HeaterThermal Expansion Lines.Relief Inlet Relief ValveHigh Altitude Leak TestingPressure Testing the Gas Supply System Gas SupplyRemote Control Installation Connecting the remote control to the water heater Remote Control InstallationIndoor or Outdoor water heaters Electrical ConnectionIndoor water heaters only Indoor Models SwitchDo’s Hot and Cold Pipe Insulation InstallationDuring Installation of this water heater… Insulation BlanketsInstallation Check List To Turn OFF GAS to Appliance Lighting the water heaterOperating the water heater Safety PrecautionsWater Temperature Setting Time/Temperature Relationship in ScaldsWater Temperature Setting… Drain heater. See Draining Water Heater section on Routine Preventative MaintenanceHousekeeping Condensate Trap Inspection Venting System InspectionBurner Inspection Vacation and Extended Shut-DownFreeze Protection Draining the Water HeaterBefore You Call For Service… Outdoor Water Heater Only Indoor Water Heater OnlyInstructions For Placing a Parts Order Replacement PartsTemperature Setting DIP Switch Adjustment If YOU Need Service

RUTG2-42(PVN)(PVP), RUTG2-53-(PVN)(PVP)(XN)(XP), RTG2-53-(PVN)(PVP)(XN)(XP), PH-16(FISN)(FISP), RMTG2-53-(PVN)(PVP)(XN)(XP) specifications

Rheem’s innovative line of tankless water heaters, including the PTG2-42(PVN)(PVP), RTG2-42(PVN)(PVP), PH20R-(IFSN)(IFSP)(OFN)(OFP), RMTG2-42(PVN)(PVP), and RMTG2-53-(PVN)(PVP)(XN)(XP), represents a significant advancement in residential and commercial water heating technologies. These models are designed to deliver hot water on demand, ensuring efficiency and convenience while minimizing energy consumption.

One of the standout features of these Rheem models is their energy efficiency. Employing advanced condensing technology, they are capable of converting up to 98% of the energy consumed into hot water. This impressive efficiency reduces utility bills and makes them an environmentally friendly choice compared to traditional tank water heaters.

The PTG2 and RTG2 series are particularly versatile, accommodating various installation needs. Their compact design allows for both indoor and outdoor installation, making them ideal for homes with limited space. Additionally, they are equipped with a multiple venting option, which provides flexibility in installation locations.

The PH20R series incorporates Rheem’s proprietary modeling and simulation technologies to optimize performance. These models feature enhanced safety functions and user-friendly digital controls, allowing homeowners to easily set and monitor their water temperatures. The ease of use extends to maintenance as well, as many components are accessible for routine checks and cleaning.

Another significant advantage of the RMTG2 models is their integrated Wi-Fi connectivity, enabling users to manage their water heating systems remotely through Rheem’s mobile app. This smart technology provides real-time data, alerts, and allows for temperature adjustments, ensuring that users always have hot water when they need it.

Rheem’s tankless water heaters also boast a robust warranty, a testament to their durability and reliability. With options that cater to various household sizes and hot water needs, these models can provide continuous hot water for homes with multiple bathrooms and heavy consumption.

For those seeking cost-effective, efficient, and smart water heating solutions, the Rheem PTG2, RTG2, PH20R, RMTG2-42, and RMTG2-53 series stand out as top contenders in the market. Their combination of advanced technology, energy savings, and user-friendly features position them as industry leaders, providing long-term benefits for any homeowner.