Rheem PH-16(FISN)(FISP), PTG2-42(PVN)(PVP), RUTG2-42(PVN)(PVP) warranty Water Temperature Setting…

Page 28

Notice: The remote control cannot be turned on when water is flowing or circulating through the water heater.

Water Temperature Setting…

Maximum water temperature occurs while the burner is on. To determine the water temperature, turn on a hot water faucet and place a thermometer in the water stream. Water temperature at the faucet may vary depending on season and length of pipe from the water heater.

The factory setting of the remote control temperature range is between 100°F (38°C) and 120°F (49°C).

The remote control is factory preset to 100°F (38°C).

To turn the remote control ON or OFF, press the POWER button.

To adjust the temperature to a required setting, press the UP arrow temperature button.

Pressing the UP or DOWN temperature adjustment buttons will change the temperature set point.

The temperature set point on the remote control cannot be increased above 112°F (44°C) when a hot water faucet is in the open position.

Notice: The factory setting allows operating temperatures between 100°F (38°C) and 120°F (49°C). Temperatures of up to 140°F (60°C) can be achieved with the MAIN (UMC-117) remote control and a dip switch adjustment. Only qualified service personnel should perform this adjustment. Only factory authorized remote control(s) should be used.

The hottest temperature water will be at the hot water faucet closest to the water heater.

Always remember to test the water temperature with your hand before use and remember that hotter water increases the risk of scald injury.

Always supervise young children or others who are incapacitated.

The water heater is equipped with a device that will shut off the gas supply to the burner if the water heater exceeds normal operating temperatures. Refer to the “Before You Call For Service” section located near the back of this manual, or contact your dealer.

!WARNING: Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

If the water heater has been subjected to fire, flood, physical damage, or has been under water, turn off the manual gas shut-off valve(s), and do not operate the water heater again until it has been checked by qualified personnel.

Notice: The water heater may not operate with a small water flow. In such case, increase the water flow. If water heater still does not operate and hot water faucet is completely open, increase the temperature setting on the remote control.

Notice: Display shows °F only.

In Use Indicator

(Lit during operation)

PRIORITY

LED Display

(Displays water °F temperature and error

codes)

POWER

ON/OFF

 

 

Higher (Hotter)

 

 

Lower (Cooler)

100 102 104 106 108 110 112

114 116 118 120*

125 130 135 140

°F

38

39

40

41

42

43

44

46

47

48

49*

52

54

57

60

°C

Priority Indicator

Temperature

Adjustment

Buttons

ON/OFF

Indicator

*Temperatures above 120°F (49°C) can be achieved by adjusting the dip switch. See page 35 for dip switch adjustment.

28

Image 28
Contents Tankless Water Heater Defects or other reproductive harmThat will result in death or serious You can find them on a label on the applianceInjury Install and Properly Vent the Water HEATER… N G E R Natural GAS and Liquefied Petroleum Models Read and Follow this Safety Information Carefully Installing the Outdoor water heater Location of the Outdoor water heaterInstalling the Indoor water heater Location of Indoor Water HeaterInstalling the water heater Combustion and Ventilation Air Indoor Water Heater OnlyCorrosive Atmospheres Inspect ShipmentVenting Venting LengthsMaximum Vent Length Minimum Vent Length The ventingAppliance Vent Adapter Venting Through Closed SpacesDraining the Condensate Canadian Installations Horizontal Vent Terminal LocationIndoor Water Heater Additional ConsiderationsVent Horizontal Wall Thimble Installation Vertical Vent Installation Vertical Vent Termination LocationThermal Expansion Mounting the Water HeaterWater Supply Connections Lines.Relief Relief Valve InletLeak Testing Pressure Testing the Gas Supply SystemGas Supply High AltitudeRemote Control Installation Remote Control Installation Connecting the remote control to the water heaterIndoor water heaters only Electrical ConnectionIndoor or Outdoor water heaters Switch Indoor ModelsHot and Cold Pipe Insulation Installation During Installation of this water heater…Insulation Blankets Do’sInstallation Check List Lighting the water heater To Turn OFF GAS to ApplianceSafety Precautions Water Temperature SettingTime/Temperature Relationship in Scalds Operating the water heaterWater Temperature Setting… Housekeeping Routine Preventative MaintenanceDrain heater. See Draining Water Heater section on Venting System Inspection Burner InspectionVacation and Extended Shut-Down Condensate Trap InspectionDraining the Water Heater Freeze ProtectionBefore You Call For Service… Indoor Water Heater Only Outdoor Water Heater OnlyReplacement Parts Instructions For Placing a Parts OrderTemperature Setting DIP Switch Adjustment If YOU Need Service

RUTG2-42(PVN)(PVP), RUTG2-53-(PVN)(PVP)(XN)(XP), RTG2-53-(PVN)(PVP)(XN)(XP), PH-16(FISN)(FISP), RMTG2-53-(PVN)(PVP)(XN)(XP) specifications

Rheem’s innovative line of tankless water heaters, including the PTG2-42(PVN)(PVP), RTG2-42(PVN)(PVP), PH20R-(IFSN)(IFSP)(OFN)(OFP), RMTG2-42(PVN)(PVP), and RMTG2-53-(PVN)(PVP)(XN)(XP), represents a significant advancement in residential and commercial water heating technologies. These models are designed to deliver hot water on demand, ensuring efficiency and convenience while minimizing energy consumption.

One of the standout features of these Rheem models is their energy efficiency. Employing advanced condensing technology, they are capable of converting up to 98% of the energy consumed into hot water. This impressive efficiency reduces utility bills and makes them an environmentally friendly choice compared to traditional tank water heaters.

The PTG2 and RTG2 series are particularly versatile, accommodating various installation needs. Their compact design allows for both indoor and outdoor installation, making them ideal for homes with limited space. Additionally, they are equipped with a multiple venting option, which provides flexibility in installation locations.

The PH20R series incorporates Rheem’s proprietary modeling and simulation technologies to optimize performance. These models feature enhanced safety functions and user-friendly digital controls, allowing homeowners to easily set and monitor their water temperatures. The ease of use extends to maintenance as well, as many components are accessible for routine checks and cleaning.

Another significant advantage of the RMTG2 models is their integrated Wi-Fi connectivity, enabling users to manage their water heating systems remotely through Rheem’s mobile app. This smart technology provides real-time data, alerts, and allows for temperature adjustments, ensuring that users always have hot water when they need it.

Rheem’s tankless water heaters also boast a robust warranty, a testament to their durability and reliability. With options that cater to various household sizes and hot water needs, these models can provide continuous hot water for homes with multiple bathrooms and heavy consumption.

For those seeking cost-effective, efficient, and smart water heating solutions, the Rheem PTG2, RTG2, PH20R, RMTG2-42, and RMTG2-53 series stand out as top contenders in the market. Their combination of advanced technology, energy savings, and user-friendly features position them as industry leaders, providing long-term benefits for any homeowner.