9.Slightly push in and turn control
knob counterclockwise to the ON position.
10.Wait one minute and switch remote selector switch to the ON position to light burner.
11.Set flame adjustment knob to any level between HI and LO.
Pilot Burner
Ignitor
Electrode
Figure 27- Pilot
CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.
WARNING: Make sure the re- mote selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on auto- matically with remote selector switch in the ON position.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. | Turn control knob clockwise |
| to the OFF position. |
2. | Set remote selector switch in the OFF |
THERMOSTAT
CONTROL
OPERATION
The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The Burners will turn on and off automati- cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 6 under Light- ing Instructions, page 15 and 16.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, column 1.
HAND HELD REMOTE
OPERATION
NOTICE: You must light the pilot before using the
1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the remote selector switch to the REMOTE position. The burners will come on. You can now turn the burners on and off with the
IMPORTANT: Do not leave the re- mote selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.
2.Select the MANUAL or AUTO button on the
•In MANUAL mode, turn burners on or off by pressing the ON or OFF buttons on the
•In AUTO mode, the room tempera- ture is controlled by the thermo- stat in the
IMPORTANT: The
3.Use the STATUS button on the hand- held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera- tion mode being used when the sta- tus button is pressed.
4.To turn the burners off when oper- ating in the MANUAL mode, press the OFF button. If operating in the auto mode, press the manual button, then press the OFF button The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the con- trol knob on the heater to the OFF position or set remote selector switch to OFF position.
position to prevent draining battery. |
Flame Adjustment Knob | Control Knob in On Position |
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one of the following:
•Turn control knob clockwise to the PILOT position.
•Use remote control manual OFF button.
•Set remote selector switch in the OFF position.
IH |
|
| IL | |
ON |
| F | P | O |
| O |
|
| T |
OFF |
|
| O | |
|
|
| ||
|
|
| N | |
REMOTE |
|
|
| |
|
|
|
| |
LO |
|
|
|
|
Remote Selector Switch in Remote Position
Figure 28 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
16 | 104307 |