Desa CGB3924PR, CGB3930PR installation manual Installing Logs CGD3924PR, Installing Back Log #1

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

INSTALLING LOGS (CGD3924PR)

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. If so, repo- sition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in the grate base behind the burner (see Figure 18).

2.Place the base of the middle log (#2) in the U-shaped slots of the grate base in front of the back log. The cutout on the right of the middle log should fit over the burner (see Figure 19). Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is centered over the burner “U” bend.

3.Locate the recesses on the back of the front log (#3). Fit these recesses be- tween the posts of the grate base (see Figure 20).

4.Locate the notches in the bottom of the crossover log (#4). Place the crossover log on top of the middle log and front log. Make sure the notches of the cross- over log lines up with rectangular knobs on top of the middle and front logs (see Figure 21).

5.Add lava rock around base of heater. Do not place any lava rock on logs or burner.

Back Log (#1)

Peg

Hole in

Grate Base

Burner

Figure 18 - Installing Back Log (#1)

Middle Log (#2)

Tab

Burner

Cutout

“U” Bend

U-Shaped

Slot

Figure 19 - Installing Middle Log (#2)

Front Log (#3)

Post

PostRecess

Figure 20 - Installing Front Log (#3)

Crossover Log (#1)

Notches

Rectangular

Knobs

Figure 21 - Installing Crossover Log (#4)

Continued

104307

13

Image 13
Contents What to do if YOU Smell GAS Safety Information Product Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined Space and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation InstallationCheck GAS Type Minimum Wall and Ceiling Clearances see FigureMinimum Non-Combustible Material Clearances If Not Using MantelFloor Clearances Mantel ClearancesConnecting to GAS Supply Installing Heater Base AssemblyInstallation Items Needed Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Volt Battery InstallationInstalling 9-Volt Alkaline Battery In Receiver Installing 9-Volt Battery In Hand- Held Remote Control UnitInstalling Back Log #1 Installing Logs CGD3924PRInstalling Middle Log #1 Installing Logs on Models CGB3924PR and CGB3930PROperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Hand Held Remote OperationInspecting Burners Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Wiring Diagram Accessories SpecificationsTechnical Service Service HintsCGD3924PR Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListCGB3924PR CGB3930PR CGB3924PR Parts Under Warranty Replacement PartsParts not Under Warranty Parts Central104307 Warranty Information