SPECIFICATIONS

 

CGD3924PR/CGB3924PR/CGB3930PR

Btu (Variable)

20,000/39,000

Type Gas

Propane Only

Ignition

Piezo

Manifold Pressure

8.0" W.C.

Inlet Gas

 

Pressure (in. of water)

 

Maximum

14"

Minimum*

11"

Shipping Weight

30 lbs.

* For the purpose of input adjustment

WIRING DIAGRAM

ACCESSORIES

Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, either contact your near- est Parts Central (see page 26) or call DESA International’s Sales Department at 1-800- 972-7879 for referral information. You can also write to the address listed on the back page of this manual.

On

 

Off

Receiver

Remote

Thermopile

White

Red

TPTH TH

Gas Control

TPTH TP

Red

White

MANUAL SHUTOFF

VALVE - GA5010

Manual shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at

1-800-DESA LOG (1-800-337-2564).

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

FIREPLACE HOOD

BLACK - GA6050

BRASS - GA6052 ANITQUE BRASS - GA6053

Helps deflect heat away from mantel or wall above fireplace.

LAVA ROCK - GA6060 (Not Shown)

Order when additional rock is desired. (3 lb. bag)

104307

21

Image 21
Contents What to do if YOU Smell GAS Safety Information Product Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined Space and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation InstallationCheck GAS Type Minimum Wall and Ceiling Clearances see FigureMinimum Non-Combustible Material Clearances If Not Using MantelFloor Clearances Mantel ClearancesInstalling Heater Base Assembly Connecting to GAS SupplyInstallation Items Needed Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Volt Battery InstallationInstalling 9-Volt Alkaline Battery In Receiver Installing 9-Volt Battery In Hand- Held Remote Control UnitInstalling Back Log #1 Installing Logs CGD3924PRInstalling Middle Log #1 Installing Logs on Models CGB3924PR and CGB3930PRFor Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Hand Held Remote OperationInspecting Burners Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Wiring Diagram Accessories SpecificationsTechnical Service Service HintsCGD3924PR Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListCGB3924PR CGB3930PR CGB3924PR Parts Under Warranty Replacement PartsParts not Under Warranty Parts Central104307 Warranty Information