Inverter Specifications

Inverter Specifications

Inverter Specifications

All inverter specifications are at nominal conditions; 1000 W resistive load, 12 Vdc inverting on the IP1012 AL, 120 Vac, unless otherwise specified.

Inverter specifications

Output wave form

Modified sine wave

 

 

Output power continuous

1000 Vac continuous

 

 

Surge rating

3000 VA for 30 seconds at –40 °F to 77 °F

 

(–40 °C to 25 °C)

 

See Figure A-1 for output at different

 

temperatures.

 

 

Operating voltage range

10.4 Vdc to 16.0 Vdc

 

 

Input DC voltage rating

12 Vdc

 

 

Output voltage

120 Vac RMS

 

 

Output voltage regulation

108 to 125 Vac under steady state 0 to 1000 W

 

load with 10.6 to 14.5 Vdc input at 25 °C

 

(77 °F)

 

108 to 132 Vac up to 1000 W, 10.6 to 16 Vdc

 

input at – 40 °F to 185 °F (–40 °C to 85 °C)

 

 

Output frequency

60.0 ± 0.1 Hz from – 40 °F to 185 °F (– 40 °C to

 

85 °C) ambient temperature

 

 

Power factor allowed

All (0 to 1, leading or lagging)

 

 

Peak efficiency

Greater than 93% at 12.6 Vdc input at 77 °F

 

(25 °C)

 

 

Idle power consumption

Less than 15 W (inverting with 120 Vac output

 

and no load)

 

 

Auto-shutdown mode

Inverter output is less than 15 ±5 W and battery

 

is less than 13 Vdc for 8 hours

 

 

Off mode power

Less than 120 mW when inverter switch is off or

consumption

in auto off mode

 

 

975-0337-01-01

A–3