Inverter Specifications
Inverter Specifications
All inverter specifications are at nominal conditions; 1000 W resistive load, 12 Vdc inverting on the IP1012 AL, 120 Vac, unless otherwise specified.
Inverter specifications
Output wave form | Modified sine wave |
|
|
Output power continuous | 1000 Vac continuous |
|
|
Surge rating | 3000 VA for 30 seconds at |
| |
| See Figure |
| temperatures. |
|
|
Operating voltage range | 10.4 Vdc to 16.0 Vdc |
|
|
Input DC voltage rating | 12 Vdc |
|
|
Output voltage | 120 Vac RMS |
|
|
Output voltage regulation | 108 to 125 Vac under steady state 0 to 1000 W |
| load with 10.6 to 14.5 Vdc input at 25 °C |
| (77 °F) |
| 108 to 132 Vac up to 1000 W, 10.6 to 16 Vdc |
| input at – 40 °F to 185 °F |
|
|
Output frequency | 60.0 ± 0.1 Hz from – 40 °F to 185 °F (– 40 °C to |
| 85 °C) ambient temperature |
|
|
Power factor allowed | All (0 to 1, leading or lagging) |
|
|
Peak efficiency | Greater than 93% at 12.6 Vdc input at 77 °F |
| (25 °C) |
|
|
Idle power consumption | Less than 15 W (inverting with 120 Vac output |
| and no load) |
|
|
Inverter output is less than 15 ±5 W and battery | |
| is less than 13 Vdc for 8 hours |
|
|
Off mode power | Less than 120 mW when inverter switch is off or |
consumption | in auto off mode |
|
|