| Troubleshooting | |
|
|
|
|
|
|
Table | Troubleshooting reference (Continued) |
|
|
| |
Symptom |
| Possible Problem |
| Remedy | |
|
| ||||
|
|
|
|
| |
Loads stop operating without | Too many appliances have |
| Reduce the number of loads. | ||
warning after they have been | reduced the battery voltage to |
| Allow the inverter to cool and | ||
running. |
| shutdown level. |
| restart. Recharge the batteries. | |
Shorepower is not connected. |
|
|
|
| |
|
| Ambient temperature is too |
| Disconnect appliances and let the | |
|
| high. |
| unit cool down. | |
|
|
|
|
| |
The inverter will not work | Remote switch may be |
| Check that the remote switch is | ||
even after toggling the switch, | disconnected at the unit |
| firmly connected. | ||
charging the batteries, and |
|
|
|
| |
letting the unit cool down. | Fuse on the unit (shown in |
| Replace the fuse or return the unit | ||
|
|
| |||
|
| Figure |
| to an authorized Xantrex dealer. | |
|
|
|
|
| |
AC voltage at receptacles | Wrong type of voltmeter being |
| Use a true RMS meter | ||
reads low. |
| used. |
|
|
|
|
|
|
|
| |
In inverter mode, times to | Bad battery cable or corroded |
| Check the cables and connectors | ||
shutdown are getting shorter | battery terminals. |
|
|
| |
for the same kind of AC load | Batteries too old or damaged. |
| Replace the batteries. | ||
|
|
|
|
|
|
Blinking Lights on the Remote Switch
You may encounter different sequences of blinking lights when the inverter is enabled (i.e., switch is on) or the unit is charging. Light sequences are described as follows:
Blink Level 1 | Fast blink | Light is on for 1/4 second and off for |
|
| 1/4 second |
|
|
|
Blink Level 2 | Slow blink | Light is on for 1/2 second and off for |
|
| 1/2 second |
|
|
|
Blink Level 3 | Very slow blink | Light is on for one second and off for |
|
| one second |
|
|
|