To replace the fuse:

Replacing the Fuse

To replace the fuse:

1. Lift the fuse cover off as shown in Figure 3-2.

3

CAUTION: Do not overtighten fuse nuts!Manual background 1

2 Manual backgroundManual background

Figure 3-2Removing the fuse cover

2.Remove the blown fuse and install the new fuse.

Be sure to use a lock washer when replacing the nuts. Tighten to a torque of 4 to 5.5 ft-lb (5.5 to 7.5 Nm).

.

CAUTION: Do not overtighten fuse nuts!

3.Replace the fuse cover by placing it over the fuse and pressing down until it snaps into place.

If the fuse blows a second time without being able to operate the unit, do not change the fuse again. Call your authorized Xantrex dealer.