TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating log set where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Log Set produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most log sets. If noise is excessive, contact qualified ser- vice person

Log Set produces unwanted odors

1.

Log Set burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Open flue to maximum. Stop using odor causing products while log set is running

2.Locate and correct all leaks (see Check- ing Gas Connections, page 8)

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 8)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

 

 

top of page

 

ing Gas Connections, page 8)

www.desatech.com

901272

17

Image 17 Contents
For Use with Log Sets What to do if YOU Smell GASModels VVSA18R VVDA24R, and VVDA30RVented GAS Logs Safety InformationRemote Ready Safety VALVE/PILOT Product FeatureProduct Identification Local Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsFlue Opening Specifications InstallationVenting Specifications for Installation Check GAS TypeConnecting to GAS Supply Installing Damper ClampInstallation Items Needed Pressure Testing Gas Supply Piping SystemTest Pressures Equal To or Less Than 1/2 Psig Hearth KIT Assembly and InstallationKit Assembly Burner Inlet Fitting Adjusting Regulator Pressure For Propane/LP ConversionPropane/LP Gas Conversion Testing Burner for Leaks Remote Control OptionsNo Optional Accessories Changing Pilot OrificeFor Your Safety Read Before Lighting Installing the Grate and LogsOperating Appliance Adding PAN Material Lighting Instructions Manual Lighting Procedure To Turn OFF GAS To Appliance Shutting Off ApplianceCuring Logs GWMS2 Wall Mounted Switch OptionalOptional Remote Operation Ghrc OperationObserved Problem Possible Cause Remedy TroubleshootingClean pilot see Cleaning and Mainte Gas leak. See Warning statement at TopModels VVSA18R VVSA24R, VVDA18R VVDA24R, and VVDA30R Illustrated Parts BreakdownParts List LOG SET Models VSLR18, VSLR24, VDLCR18, VDLCR24, and VDLCR30 Parts List Accessories Cleaning and MaintenanceReplacement Parts 901272 International Warranty Information