INSTALLATION

CAUTION: Do not remove the metal data plates attached to the burner pan. The data plates contain important warranty in- formation.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimney flue for damage.

NOTICE: Installation, service, and repair of this appliance must be performed by a qualified installer, service agency, company or gas supplier experienced with this type of gas appliance. Only fac- tory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components or ac- cessory items will void the manufacturer’s warranty, and may result in a hazardous condition.

MODEL

DESCRIPTION

Btu Input

Btu Input

Natural Gas

Propane/LP Gas

VVSA18R

18" Single Burner

50,000

40,000

VVSA24R

24" Single Burner

60,000

50,000

VVDA18R

18" Dual Burner

55,000

45,000

VVDA24R

24" Dual Burner

65,000

55,000

VVDA30R

30" Dual Burner

70,000

60,000

 

 

 

 

The minimum vent opening on all models is 8" in diameter.

MINIMUM FIREBOX SIZES

LOG

FRONT

BACK

 

 

SIZE

WIDTH

WIDTH*

DEPTH

HEIGHT

 

 

 

 

 

18"

34"

16"

14"

18"

24"

35 3/4"

17"

15 1/2"

18"

30"

42"

27"

18"

18"

 

 

 

 

 

*At depth indicated

FUEL PRESSURE

SPECIFICATIONS (W.C.)

 

Inlet

 

 

Manifold*

 

 

 

 

 

NG

5.5"-10.5"

 

3.5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LP

11"-13"

 

10"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* ± .2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BURNER ORIFICE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOG

 

 

NATURAL

 

PROPANE/LP

SIZE

IN.

 

NUM.

 

COLOR

IN.

 

NUM.

COLOR

18"

.129

 

30

 

 

Green

.073

 

49

Red

24"

.141

 

28

 

 

Yellow

.086

 

44

Orange

30"

.157

 

22

 

 

Yellow/Blue

.089

 

43

Black

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4 - Technical Information Charts

FLUE OPENING

SPECIFICATIONS

Note: This vented appliance must be in- stalled only in a solid-fuel burning fireplace with a working flue and constructed of non- combustible material.

The charts in Figure 4 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable be- fore installation is attempted.

The fireplace must include a working flue and venting system with the minimum open- ings shown in the Figure 4.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, you must convert the appliance to propane/LP. Follow the instructions on page 10.

If the fireplace does not have a gas supply shut-off valve, one must be installed.

VENTING SPECIFICATIONS FOR INSTALLATION

The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chim- ney. If the smoke spills out into the room, extinguish the flame and remove any ob- struction until proper venting is achieved.

The chimney flue must remain open a mini- mum of 3" at all times during the operation of this log set (see Figure 5, page 8).

Continued

901272

7

Image 7 Contents
VVDA24R, and VVDA30R What to do if YOU Smell GASFor Use with Log Sets Models VVSA18RVented GAS Logs Safety Information Unpacking Product Feature Remote Ready Safety VALVE/PILOT Product Identification Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Appliance Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingCheck GAS Type InstallationFlue Opening Specifications Venting Specifications for InstallationPressure Testing Gas Supply Piping System Installing Damper ClampConnecting to GAS Supply Installation Items NeededKit Assembly Hearth KIT Assembly and InstallationTest Pressures Equal To or Less Than 1/2 Psig Propane/LP Gas Conversion Adjusting Regulator Pressure For Propane/LP ConversionBurner Inlet Fitting Changing Pilot Orifice Remote Control OptionsTesting Burner for Leaks No Optional AccessoriesAdding PAN Material Installing the Grate and LogsFor Your Safety Read Before Lighting Operating ApplianceShutting Off Appliance Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceGhrc Operation GWMS2 Wall Mounted Switch OptionalCuring Logs Optional Remote OperationObserved Problem Possible Cause Remedy TroubleshootingClean pilot see Cleaning and Mainte Gas leak. See Warning statement at TopModels VVSA18R VVSA24R, VVDA18R VVDA24R, and VVDA30R Illustrated Parts BreakdownParts List LOG SET Models VSLR18, VSLR24, VDLCR18, VDLCR24, and VDLCR30 Parts List Replacement Parts Cleaning and MaintenanceAccessories 901272 International Warranty Information