Desa VVSA18R, VVSA24R Remote Control Options, Testing Burner for Leaks, No Optional Accessories

Page 11

OWNER’S MANUAL

INSTALLATION

Continued

Changing Pilot Orifice

The pilot is provided with a natural gas orifice installed. For propane/LP gas you must remove it and replace it with a pro- pane/LP orifice. The hardware kit contains an propane/LP orifice with a red stripe for converting the pilot.

1.Gently loosen and remove the pilot line connection from the bracket (see Figure 18).

2.Replace the orifice (see Figure 18) with the propane/LP pilot orifice with the red stripe.

3.Replace and tighten the pilot line to the bracket.

4.Continue with step 7 under Hearth Kit Assembly and Installation, page 9.

Note: Follow the instructions under the sec- tion, Testing Burner for Leaks, column 3.

Pilot

Orifice

 

O

 

 

F

O

F

N

 

 

 

TOL I

P

 

 

Figure 18 - Installing Propane/LP Pilot Orifice

REMOTE CONTROL OPTIONS

GHRC

If you are using the GHRC remote control option, you must first connect the leads of the receiver to the terminal block on the gas control (see Figure 19).

1.Connect the leads to the male fast-on terminals marked TH and TPTH.

2.Install a 9V battery (refer to the instruc- tions included with the GHRC).

3.Install a 9V battery into the hand-held transmitter.

4.Insert the receiver into the simulated log control cover, with the raised cyl- inder fitting into the hole in the cover.

5.The cover may be moved aside when operation of the gas control is necessary.

Control

Valve

Fast-On Terminals

Figure 19 - Connecting Wire Terminals

GWMS2

When installing the GWMS2 remote wall switch option, follow all instructions in- cluded with the accessory. Connect wires as shown in Figure 19. You will need to route the wiring away from the gas control and log set in a way which prevents direct radiant heat on the wires.

No Optional Accessories

If you choose no remote accessories at this time, the provided jumper wire must be installed to the terminal block on the gas control. Connect the lead to the fast-on terminals marked TH and TPTH.

TESTING BURNER FOR LEAKS

1.Generously apply soapy solution to all connections.

WARNING: Never check for gas leaks with open flame.

2.Light the burner with the shut-off valve no more than half open and holding a match slightly in front of the pan (see Lighting Instructions, page 13).

3.Inspect all connections for bubbles, raw gas odor, or flame from any area other than the burner (leaks). If leaks are de- tected, shut off the gas valve immedi- ately. Tighten, or reassemble the loose connection(s) using pipe joint com- pound until burner system is leak free.

4.When the burner is tested and leak free, observe the individual tongues of flame on the burner. Note: The burner design includes more ports on the outside of the bar. Make sure that all ports are clear and producing flame evenly across the burner. If any ports appear blocked, clear them by removing the burner manifold and reaming the ports with a modified paper clip or other suitable tool.

5.When finished testing, turn the gas shut- off valve OFF to extinguish all flames.

Continued

901272

11

Image 11 Contents
VVDA24R, and VVDA30R What to do if YOU Smell GASFor Use with Log Sets Models VVSA18RVented GAS Logs Safety InformationUnpacking Product FeatureRemote Ready Safety VALVE/PILOT Product Identification Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type Installation Flue Opening Specifications Venting Specifications for InstallationPressure Testing Gas Supply Piping System Installing Damper ClampConnecting to GAS Supply Installation Items NeededTest Pressures Equal To or Less Than 1/2 Psig Hearth KIT Assembly and InstallationKit Assembly Burner Inlet Fitting Adjusting Regulator Pressure For Propane/LP ConversionPropane/LP Gas Conversion Changing Pilot Orifice Remote Control OptionsTesting Burner for Leaks No Optional AccessoriesAdding PAN Material Installing the Grate and LogsFor Your Safety Read Before Lighting Operating ApplianceShutting Off Appliance Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceGhrc Operation GWMS2 Wall Mounted Switch OptionalCuring Logs Optional Remote OperationObserved Problem Possible Cause Remedy TroubleshootingClean pilot see Cleaning and Mainte Gas leak. See Warning statement at TopModels VVSA18R VVSA24R, VVDA18R VVDA24R, and VVDA30R Illustrated Parts BreakdownParts List LOG SET Models VSLR18, VSLR24, VDLCR18, VDLCR24, and VDLCR30 Parts List Accessories Cleaning and MaintenanceReplacement Parts 901272 International Warranty Information