Fostex CR500 owner manual Power connection, Realtime clock setting, Press the ENTER/YES key

Page 14

CD-R/RW MASTER RECORDER CR500 (Preparation before using the CR500)

Power connection

Connect the supplied power cable to the [AC IN] connector on the rear panel first, and then to the AC outlet.

 

ANALOG INPUT

 

L

ANALOG OUTPUT

R

L

L

R

L

 

 

R

R

 

 

BALANCED [+4dBu]

UNBALANCED [-10dBV]

 

BALANCED [+4dBu]

 

DIGITAL

 

 

 

 

INPUT

OUTPUT

 

 

 

 

GPI

CAUTION

AVIS: RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

WARNING:

TO REDUCE THE RISK OF FIRE OR ELECTRIC

SHOCK, DO NOT EXPOSE THIS EQUIPMENT

TO RAIN OR MOISTURE.

ACININ

1:GND 2:HOT 3:COLD

Power cable

<Notes>: Connect the CR500 to the AC outlet of the voltage indicated on the rear panel. If you use the unit in another country where the power voltage or AC connec- tor type is different, consult your dealer or local Fostex service station.

Realtime clock setting

After making power connection, turn on the CR500 and make setting of the realtime clock.

The realtime clock data is used for date/time of creation of an audio file which is made when you make a recording to a BWF formatted CD-R/RW disc.

By default, the realtime clock is set according to local date/time of the factory. There- fore, set the clock correctly according to your local date/time before using.

 

 

 

 

 

 

 

 

 

 

6

 

2,3,4,5,6,7

 

 

 

 

 

 

 

ACCESS

DISPLAY

MEMORY MEMORY SET

LOCATE

SHIFT

EXIT/NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

 

 

 

 

 

 

 

 

 

 

 

CONTRAST

space

ABC

DEF

EDIT TIME

PUSH

 

 

 

 

 

 

 

 

PLAY MODE

 

 

 

 

CLEAR

MENU/ENTER/YES

 

 

 

 

 

 

 

FILE SEL

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

5

6

+10

 

 

 

 

 

 

 

 

 

PROGRAM SET

DIR SEL

GHI

JKL

MNO

 

 

 

 

 

 

 

 

 

 

REPEAT

REC RDY

 

 

 

 

SKIP/CURSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

8

9

0

 

 

 

 

 

 

L

 

 

R

 

PQRS

TUV

WXYZ

symbol

 

 

 

 

 

 

 

 

 

OPEN/CLOSE

 

REC END

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABS 0

 

 

 

 

 

POWER

USB

MIN

MAX

MIN

MAX

MIN

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(KYBD ONLY)

PHONES

 

 

INPUT LEVEL

 

RECORD

 

STOP/HOME

 

PLAY

REWIND

F FWD

1

 

 

 

 

 

 

 

 

 

8

 

 

6

 

1)Press the [POWER] switch to turn on the CR500.

Soon after turning on the power of the unit, the display shows the screen below.

The time display shows "-m--s---ms", showing that the CR500 started up with no disc loaded on the drive.

2)Press the [ENTER/YES] key.

The unit enters the MENU mode and the display now shows the MENU list screen on which "SYS SETUP " is highlighted.

3)While "SYS SETUP " is highlighted, press the [ENTER/YES] key again.

14

Image 14
Contents CD-R/RW Master Recorder 8588076000Safety Instructions CD-R/RW Master Recorder CR500 Safety instructions/ContentsImportant Safety Instructions Table of contents Selecting a song to be played back Playback in the Memory Play modeRecording aWAV file Disk Utility menu About Menu mode SYS Setup menuPlay Setup menu About this manual Precautions on installation Overview CD-R/RW Master Recorder CR500 OverviewMain features Supporting two recording formatsEasy-to-see large display and level meters High-performance CD-R/RW drive builtVarious playback modes For worldwide use USB keyboard can be used for file name entry, etcVersatile analog and digital connectability Fader start functionPreparation before using the CR500 Press the Power switch to turn on the CR500 Power connectionRealtime clock setting Press the ENTER/YES keyAfter editing date/time data, press the ENTER/YES key Using the numeric keysPress the ENTER/YES key again Format types Initial format of the CD-R/RW discUsable discs Handling of CD-R/RW discsRecorded CD-R/RW disc Unformatted CD-R/RW discUnused formatted CD-R/RW disc CD-DA format audio CD including a commercially available CDPress the OPEN/CLOSE key to open the disc tray Initial format of a discRecordable time and the maximum number of tracks Use the numeric keys or Menu dial to edit the volume label Page Format type Strong contrast Adjusting display contrastWeak contrast CD-R/RW Master Recorder CR500 Names and functions Front panelRear panel Front panel section Rear panel section Screen detailsAudio file and audio track About Non-shift mode and Shift modeFront panel section DISPLAY/ Contrast key KeyLCD display Shift key Memory Play modeCLEAR/+10 key EXIT/NO keyTransport control keys Menu dial/ENTER/YES keySKIP/CURSOR keys Repeat key REC RDY keyLevel meters OPEN/CLOSE keyRear panel section Disc elapsed time Screen detailsTime information Track remaining timeTotal time indication example Play modeFile name WAV fileAudio file or audio track information Playback FS/Playback bitNext track Record modeCurrent track Input selectionDisk Utility menu screen SYS Setup menu screenPlay Setup menu screen File SEL screenConnection CD-R/RW Master Recorder CR500 ConnectionConnecting to other devices Analog audio deviceFader start connection Numeric keyboardShortcut keys USB keyboardFunction keys Control keysCD-R/RW Master Recorder CR500 Recording Closing FinalizingBWF formatted CD-R/RW disc CD-DA formatted CD-R/RW disc Connecting a sound sourcePreparation for recording Adjusting recording levels for analog input only Selecting the inputExamples below is shown Stopping recording Recording a WAV fileStarting recording Playing back a recorded audio file Press the REC RDY key to disable the record ready modeChecking the recorded audio file Closing a disc While stopped, press the OPEN/CLOSE keyRecording a CD-DA track Creating an audio CD Space key Checking the recorded audio trackPlaying back the recorded audio track STOP/HOME key Rewind key Play keyFinalizing a disc How to use the CLEAR/+10 key Method 1 Using the SKIP/CURSOR keysMethod 2 Using the Memory Selecting a song to be played backWhile stopped, press the ENTER/YES key Method 3 Using the File SEL screenGo down the menu to the File SEL menu Menu list screenCD-R/RW Master Recorder CR500 Recording CD-R/RW Master Recorder CR500 Playback/Locate Playback in the Program Play modePlayback in the Memory Play mode About play mode Playback in the ALL Play mode Home screen of the ALL Play modeDigital scrub Waveform screen in the scrub modeCueing Backward cueingPlayback in the Program Play mode Above Creating the play listWhile stopped, press the ENTER/YES key Move the cursor to Play Mode and press the ENTER/YES key To insert a song between songs in the play listMove the cursor to Save and press the ENTER/YES key Deleting a song form the play listDeleting all songs in the play list Playback in the Memory Play mode While Save is highlighted, press the ENTER/YES key Assigning audio data to a memoryWhile TNO is highlighted, press the ENTER/YES key Replacing the audio file in a memory bank Editing a memory name Editing the start time/end time by entering time dataAfter entering the desired time, press the ENTER/YES key Example when you select StartExample when you select END Example when you select SCRUB-E Deleting memory play dataFile SEL/ DIR SEL key Then press the ENTER/YES keyLocate/skip functions Locating an audio file or audio trackSKIP/CURSOR key Skipping between audio files or audio tracksLocating the specific ABS time Locate ABS 0/Locate REC END After entering the time, press the Locate Locating a point by entering a timeKey Play Setup menu CD-R/RW Master Recorder CR500 Menu mode System Setup menuAbout Menu mode SYS Setup menu Disk Utility menuAbout Menu mode Main menu name ContentsSys User Load Adjust RTCSys User Save While the recorder is stopped, press the ENTER/YES key Basic procedure for using the SYS Setup menuWhile SYS Setup is highlighted, press the ENTER/YES key Default file name Scene NAME/TAKE Number setting Default file name setting Default File NameSelecting File name mode Analog Unbalanced. This is the defaultInput selection Select Input Digital output signal format selection Digital Out Peak hold time setting Peak HoldReference level setting Ref. Level USB keyboard type setting Keyboard SelSaving SYS Setup data Sys User Save Loading SYS Setup data Sys User LoadInitializing system memory data Sys Default Set Initializing flash memory Sys Initial MemoryROM version checking Version Off Basic procedure for using the Play Setup menuCD-R/RW Master Recorder CR500 Menu mode Play Setup menu Off Play mode selection Play ModeRepeat mode on/off Repeat Off Recorder stops after starting up default Auto play mode on/off Auto PlayAuto play on/off when powered on Power On Play CD-R/RW Master Recorder CR500 Menu mode Disk Utility menu FinalizeFormatting a disc Format While Format is highlighted, press the ENTER/YES keyPress the ENTER/YES key to start formatting the disc Rewriting the file system Rewrite File Sys Press the ENTER/YES key to rewrite the system fileTo exit the Menu mode, press the STOP/ Home key Editing a file name Edit file nameEdit the file name Deleting an unnecessary audio file Delete File Press the ENTER/YES key to delete the fileRestoring a deleted audio file Restore Del. File Finalized BWF discsFinalizing a disc Finalize Press any operation key on the panelSpecifications CD-R/RW Master Recorder CR500 SpecificationsCR500 main specifications Power consumption Signal to noise ratioExternal dimensions Weight Power requirements Recording medium Sampling frequency fs/ Quantization bitPhysical dimensions 482Declaration of EC Directive Affect of Immunity on This EquipmentFor the US Customers only Fostex America Limited Warranty Shipping Fostex CO

CR500 specifications

The Fostex CR500 is a remarkable addition to the world of professional audio monitoring, offering an impressive blend of technology and user-friendly design. This studio monitor is engineered to deliver high-quality sound reproduction, making it an ideal choice for musicians, audio engineers, and home studio enthusiasts alike.

At the heart of the CR500 is its sophisticated driver technology. Featuring a 5-inch woofer and a 1-inch silk dome tweeter, the monitor delivers a well-balanced sound with clarity and depth. The woofer is designed to handle low frequencies with precision, providing deep bass response, while the tweeter ensures that high frequencies are reproduced smoothly, eliminating harshness and fatigue during long mixing sessions.

One of the standout features of the CR500 is its bi-amp system, which allows the woofer and tweeter to be powered separately. This amplification method minimizes distortion and enhances overall sound quality, allowing each driver to perform optimally. Additionally, the rear-firing bass port contributes to an extended low-frequency response, giving users a more immersive listening experience.

The CR500 is equipped with a range of control options, including a volume knob, high-frequency and low-frequency control, and a switch for adjusting the speaker's position in the room. This level of customization is crucial for achieving an accurate mix, as it allows users to tailor the sound to their specific environment.

In terms of connectivity, the Fostex CR500 comes with balanced XLR and TRS inputs, ensuring compatibility with a wide array of audio interfaces and mixing consoles. This flexibility makes it an excellent choice for both professional studios and home setups.

Build quality is another key aspect of the CR500. The cabinet is constructed from high-density MDF, which helps minimize cabinet resonance and unwanted vibrations. The sleek finish not only enhances its aesthetic appeal but also contributes to its durability.

Overall, the Fostex CR500 studio monitor stands out for its exceptional sound quality, robust build, and user-friendly features. It's an excellent choice for anyone looking to elevate their audio production experience, whether for music production, mixing, or mastering. With its combination of advanced technologies and thoughtful design, the CR500 is a reliable tool for achieving accurate and dynamic sound reproduction in any studio setting.