AquaStar 38B NG, 38B LP General Rules to Follow For Safe Operation, Combustion AIR Requirement

Page 4

GENERAL RULES TO FOLLOW

FOR SAFE OPERATION

1.You should follow these instructions when you install your heater. In the United States: The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54.

In Canada: The Installation should conform with CGA B149.(1,2) INSTALLATION CODES and /or local installation codes.

2.Carefully plan where you install the heater. Correct combustion air supply and flue pipe installation are very important. If not installed correctly, fatal accidents can be caused by lack of air, carbon monoxide poisoning or fire.

3.The place where you install the heater must have enough ventilation. The National Fire Codes do not allow water heater installation in bathrooms, bedrooms or any occupied rooms normally kept closed. See the section below on locating the heater.

4.You must vent your heater. See section on Vent Pipe Connections, Page 4.

5.The appliance must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 Psig (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 Psig (3.5Kpa). The appliance and its gas connection must be leak tested before placing the appliance in operation.

6.Keep water heater area clear and free from combustibles and flammable liquids. Do not locate the heater over any material which might burn.

7.Correct gas pressure is critical for the optimum operation of this heater (see specifications on page 2). Gas piping must be sized to provide the required pressure at the maximum output of the heater, while all the other gas appliances are in operation. Check with your local gas supplier, and see the section on connecting the gas supply.

8.Should overheating occur or the gas supply fail to shut off, turn off the gas supply at the manual gas shut off valve on the gas line.

9.Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater.

PROPER LOCATION FOR INSTALLING YOUR HEATER

Carefully select the location of your new heater. For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation.

The heater may still operate even when improperly vented. It will, however, be less efficient and could eventually damage the heater. It could even result in human sickness or death due to oxygen deprivation and carbon monoxide poisoning. Follow the guidelines below:

1.Place your heater as close to a vent or chimney as possible.

2.National building codes require that you do not install this appliance in bathrooms, bedrooms, unvented closet or any occupied rooms normally kept closed.

3.Simultaneous operation of other appliances such as exhaust fans, ventilation systems clothes dryers, fireplaces or wood stoves could create a vacuum effect in your home which could cause dangerous combustion by-products to spill back into your home rather than venting to the outside through the flue. Confirm that your Aquastar is venting properly when all these other appliances are running. See section on venting.

Do not obstruct the flow of combustion and ventilation air to the appliance. If installed near a clothes dryer it is very important that the dryer be properly vented. Failure to properly vent a dryer could result in a gradual accumulation of lint on the water heater fin coils and burners, leading to a dangerous condition of venting blockage and poor unsafe combustion.

4.Your hot water lines should be kept short to save energy. It is always best to have hot water lines insulated. Having a floor drain or sink nearby is handy in case you need to drain water from your heater.

WARNING: The water in this water heater is cold and always remains cold exept for the times that hot water is being used DO NOT INSTALL IN AN AREA WHERE IT

COULD FREEZE.

This heater is neither designed for nor approved for outside installation.

WARNING: Flammable materials, gasoline, pressurized containers, or any other items or articles that are potentially fire hazards must NOT be placed on or adjacent to the heater. The appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids.

COMBUSTION AIR REQUIREMENT

Observe the following instructions concerning combustion air.

Appliances located in unconfined spaces:

a)An unconfined space is one whose volume is greater than 50 cubic feet per 1000 Btu per hour of the combined rating of all appliances installed in the space. That would be 2000 cubic feet for the AquaStar 38B alone.

b)In unconfined spaces in buildings of conventional frame, masonry, or metal construction, infiltration is normally adequate to provide air for combustion, ventilation, and dilution of flue gasses.

4

Image 4
Contents Table of Contents For Your SafetyWhat to do if YOU Smell GAS AquaStar 38B LP and 38B NG Specifications FeaturesUnpacking the Aquastar Heater Open loop potable water and combination space heating system Proper Location for Installing Your Heater General Rules to Follow For Safe OperationCombustion AIR Requirement Could FreezeClearances Mounting InstallationVenting Maximum Inlet GAS Flow Pressure Setting Water ConnectionsAltitude Natural Gas Liquid Propane Above 4.500 ft consult your local gas supplierFor Your Safety Read Before Lighting the Pilot Operating InstructionsLighting Instructions Setting the Water TemperatureTo Turn OFF GAS to Appliance Maintenance and Service Characteristic Pilot FlameTrouble Shooting Pilot Lights but Flame Goes OUT When Button is ReleasedWater is TOO HOT Burners do not Ignite When HOT Water is Turned onWater is not HOT Enough Unbalanced pressure in waterlines HOT Water Temperature FluctuatesInsufficient gas pressure Diagram of AquaStar 38 B Interior Components Diagram and Parts List Interior Components Diagram Parts List 38B LPGInstallation Checklist Controlled Energy Corp

38B LP, 38B NG specifications

The AquaStar 38B LP and AquaStar 38B NG are cutting-edge water heating solutions designed for efficiency and performance, ideal for both residential and commercial applications. These models boast a sleek, compact design, making them suitable for installation in tight spaces while still delivering robust heating capabilities.

One of the key features of the AquaStar 38B LP and 38B NG is their advanced energy efficiency. With an impressive Energy Factor (EF) rating, these units utilize state-of-the-art heat exchange technology to maximize heat transfer and minimize energy consumption. This translates to reduced utility bills and a smaller carbon footprint, making them eco-friendly options in today’s sustainability-focused market.

The AquaStar models are available in two fuel types: LP (liquefied propane) and NG (natural gas). This dual-fuel flexibility allows users to select the ideal option based on availability and cost, ensuring optimal performance tailored to individual needs. The integration of high-quality burners further enhances the efficiency and reliability of these systems, ensuring quick recovery times and consistent hot water availability.

One notable characteristic of the AquaStar 38B units is their ability to provide continuous hot water. This makes them an excellent choice for households with high demand or commercial establishments like restaurants and hotels, where hot water is required throughout the day.

Moreover, the AquaStar 38B models are equipped with innovative safety features to enhance user protection. The built-in temperature control mechanism allows users to set their preferred water temperature, while also incorporating anti-scald technology to prevent overheating.

In terms of maintenance, the AquaStar 38B units stand out with their user-friendly design. Routine maintenance is straightforward, and the models feature easily accessible components for servicing, which contributes to their longevity and reliability.

In conclusion, the AquaStar 38B LP and 38B NG represent a fusion of efficiency, safety, and advanced technology. With their energy-saving capabilities, versatile fuel options, and robust design, these water heaters are a worthwhile investment for anyone seeking reliable and efficient hot water solutions.