SETTING THE WATER TEMPERATURE

To adjust the temperature on your AquaStar, turn on a hot water faucet to its maximum flow.At the water heater, turn the large temperature adjustment knob located beneath the main gas controls on the front of the heater all the way to the right (clockwise). See Fig 6. This will produce a temperature rise of approximately 90°F at a flow rate of .5 gallons per minute (gpm). Turning the dial all the way to the left (counterclockwise) will increase the water flowing through the heater, and will produce a temperature rise of approximately 45°F at a flow rate of 1.3 gpm. Given that average incoming water temperatures are 50°F, this heater will produce water between 140° and 95° at these flow rates. Thus one can obtain a higher flow rate, but at cooler temperatures.

Fig. 6 - Water Flow Control Knob

The position you select on the temperature adjustment knob will depend on the temperature of the incoming water (50°F is average in the U.S.). If you plan to supply the AquaStar 38 B, with preheated water (i.e.) solar installation, the unit could overheat. It will then shut off on safety when the outlet temperature reaches 185°F. For a lower temperature rise, the heater can be set for minimum burner output by sliding the gas valve control to the pilot setting symbol ( ).

MAINTENANCE AND SERVICE (see maintenance

table on back)

Approximately once a year, the AquaStar should be checked and cleaned. To remove the front cover, first remove the incandescent particle tray, then pull off the temperature adjustment knob, unscrew and remove the plastic collar and unscrew the central screw located at the bottom of the front cover. Pull main cover out toward you and lift up and out.

TH E F OLLOWI N G O PE RATIONS SHOU LD B E PERFORMED BY A QUALIFIED SERVICE PERSON:

Vent System: Should be checked annually. Clean and repair as needed.

Water Valve (Part # 8707002497): The water valve on this heater should be serviced periodically. Lubricate com- ponent #19 on page 18 with a small amount of silicon, faucet or lithium grease every two years to keep its o rings fresh and pushrod sliding smoothly. Every 3-5 years replace components #19 and #21 on page 18. The frequency will depend on the mineral content of the water and conditions of use or whenever signs of corrosion appear at the gas and water valve joint. Periodically check that the water inlet fil- ter (#25 on page 18) is clean as well.

Pilot Flame: The pilot flame should burn with a clean sharp blue flame and should resemble the diagram in Fig 7. If the flame is yellow, or if the pilot knob has to remain depressed for a long time in order to keep the pilot lighted, the pilot burner and or the pilot burner orifice may need to be cleaned, the orifice may need to be replaced, and or the air screen or pilot gas filter may need cleaning. The pilot flame should envelop approximately 10 mm (3/8") of the tip of the thermocouple. If it is too small, the pilot burner must be cleaned. The position of the Piezo igniter electrode should be approximately 3 mm (1/8") from the pilot.

3mm

Correct gap between pilot burner tip and electrode tip

Piezo Electrode

Air screen filter

10mm

3/8”

 

 

 

 

Thermocouple

Piezo

Electrode

Fig. 7 - Characteristic Pilot Flame

To clean the pilot burner and/ or the pilot orifice : Turn off the gas at the unit. Remove the cover of the heater. To do so, remove the incandescent particle tray, pull off the temperature adjustment knob and unscrew and remove the knob collar. Unscrew the central screw located at the bottom of the front cover. Pull main cover out toward you and lift up and out. Pull the air screen off, wash it and blow any lint off (See Fig 8). The pilot orifices should also be cleaned or replaced. Do not enlarge the orifice. Do not use any wire or sharp object to clean orifices. Natural gas orifices are large enough that you can usually clean them by blowing through them. LP orifices, on the other hand, are too small to clean and should be replaced. See #3 in Trouble Shooting Section. To access the pilot orifice, remove 2 screws holding pilot assembly in place. Then loosen compression fittings to expose pilot orifice.

12

6 720 606 446

Image 12
Contents For Your Safety Table of ContentsWhat to do if YOU Smell GAS Features Unpacking the Aquastar HeaterAquastar Model 38B Front View Side ViewProper Location for Installing Your Heater General Rules to Follow For Safe OperationMounting Installation Combustion AIR RequirementAppliances located in unconfined spaces Mounting the HeaterVenting Figure aMasonry Chimneys Figure C 720 606GAS Connections and Gas Regulator Water Connections Altitude Natural Gas Liquid Propane Inches W.CFor Your Safety Read Before Lighting the Pilot Operating InstructionsSetting the Water Temperature Table on backPilot does not Light No gas to the Aquastar Gas cock on gas line may not be openIn-line Aquastar gas regulator jammed usually on LP gas Pilot Lights but Flame Goes OUT When Button is Released Water valve parts may be dirty or components damagedWater is TOO HOT Heat exchanger Main gas burner Water valve720 606 Interior Components Diagram and Parts List Interior Components Diagram Parts List 38B LPGFlow chart of Aquastar 38 B Limited Warranty General720 606 720 606 Maintenance Table see pages 12 System Co. Foschan Guangdong P.R. China