FORWARD

The design of the WR430-3K complies with CAN 1-4.3 and ANSI Z21.10 (latest edition) as an instantaneous gas water heater. In addition, the WR400-3K also complies with CAN 1-2.17 for use at high altitudes, 2,000 - 4,500 ft. above sea level.

Installation, operation and maintenance instructions are provided in this manual. Installation and operation instructions should be thoroughly reviewed before proceeding with installation of the BOSCH instantaneous gas water heater.

The BOSCH instantaneous gas water heater is designed to operate on natural or propane gas: however, make sure that gas on which heater is to operate is the same as specified on the heater’s model/rating plate.

In addition to these instructions, the water heater shall be installed in accordance with CAN/CGA-B149 Installation Code (in Canada) or Z223.1-latest edition, National Fuel Gas Code (in U.S.A.) and/or local installation codes. These shall be carefully followed in all cases.

INSTALLATION INSTRUCTIONS

The Bosch WR430-3K is a high efficiency fin tube heater and should not be installed and operated during construction or building renovations if location is exposed to above normal dust levels. This can cause dust build up in the finned heat exchanger and result in damage to heater and be a hazard to health.

Note: Proper plumbing, venting, gas connections and an adequate supply of combustion air are required for safe and reliable operation. Ability equivalent to that of a licensed tradesman in the field involved is required for installation and/or service of these water heaters.

LOCATION

Before installing the BOSCH instantaneous gas water heater, consideration must be given to proper location. The location should be as close to outside vent termination as practicable, in an area with an adequate air supply and as centralized with the piping system as possible. The heater should not be located in an area where it will be subject to freezing. The heater should be located in an area where leakage of the heater or its connections will not result in damage to the area adjacent to the heater or to lower floors of the structure. See venting page 5.

Note: When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the water heater. The pan must not restrict combustion air flow.

ELECTRICAL

A grounded switched plug receptable must be provided immediately below the left hand corner of heater to accept and provide power to supplied 3 ft. (0.9m) appliance cable and plug.

AIR REQUIREMENTS

For safe operation, sufficient air for combustion, ventilation and dilution of flue gases must be available. An insufficient supply of air will result in a yellow luminous burner flame, causing carboning or sooting of the heat exchanger.

In order to prevent corrosion, make sure that the combustion air is kept free of aggressive substances. Substances that especially contribute to corrosion are halogenated hydrocarbons (e.g., chlorine and fluorine) which are contaned in solvents, paint, adhesives, propellant gases, various household cleaners, etc. Take precautionary measures as necessary.

In unconfined spaces, in buildings of normal construction, infiltration normally is adequate to provide air for combustion, ventilation and dilution of flue gases. However, a confined space must be provided with two permanent openings to provide combustion and ventilation air to the appliance. Each opening shall have a free area of one square inch per 1,000 Btu/Hr* of total input rating of all the appliances in the enclosure. One opening shall be within 12 inches of the top and one within 12 inches of the bottom of the enclosure.

* Special Note

When the WR430-3K is installed in a confined space of minimum size the openings described above must be increased in to a size of 1-1/2 square inches per 1,000 BTU/Hr. In other words, when installed in a minimum sized confined space the two openings that are to be made in the enclosure within 12 inches of the top and 12 inches of the bottom must each have a minimum free area of, (1-1½” - 2" x (130) = 195 square inches.

4

Image 4
Contents Instantaneous gas water heater What to do if YOU Smell GASUnpacking the Bosch WR430-3K Heater FeaturesNAT. GAS Propane Dimensions Reduced 4% for each 1,000 feet above sea level. SeeElectrical LocationAIR Requirements Clearance MountingIntroduction General InformationGeneral Venting Information Sizing & DistancesGeneral Code Requirements Approved Venting MaterialsVent Terminal Installation 90 el Ft straight Ft straight 4.6m 0.3mVent Installation Electrical WiringOperation and Checking the Draft Positive pressureMaintenance Drip Tray Water ConnectionsRelief Valve GAS ConnectionsService Hint FillingLighting and Operating Instructions To Turn OFF GAS to ApplianceHigh Temperature Limit Switch Temperature RegulationPressure Regulation Trouble Shooting Maintenance and ServiceNo Spark AT the Pilot Adjusting ScrewStops sparking Pilot Sparks Continuously with No Water Running Pilot Lights but Burners Will not Come onMain Burners GO OUT During HOT Water USE Water is TOO HOTHOT Water Temperature Fluctuates See onInterior Components Diagram Parts List WR430 Interior Components Diagram and Parts List Page Page Page Chauffe-eau instantané, à gaz Www astravan.comPrincipe de fonctionnement Déballage DU CHAUFFE-EAU Bosch WR430-3KMax Dimensions VoirAlimentation Électrique Lieu DinstallationDemande Dair Dégagements DE Séparation AvertissementMontage Information Générale IntroductionLatmosphère Matériaux Approuvés Pour LE Circuit DE Décharge Prescriptions Générales DES CodesInstallation DE LA Bouche DE Décharge Installation DU Système DE Décharge Câblage ÉlectriqueUtilisation ET Contrôle DU Tirage Contrôle DU TirageEntretien Points dinspectionRaccordement AUX Canalisations Deau Plateau DE RécupérationVanne manométrique et raccords S vue de dessus Soupape DE Surpression Raccordement À LA Canalisation DE GAZAllumage ET Utilisation RemplissageInterruption DE L’ALIMENTATION EN GAZ DU CHAUFFE-EAU Régulation DE LA Pression Thermostat DE Sécurité «HAUTE TEMPÉRATURE»Dépannage Ne pourra s’allumerPAS D’ÉTINCELLES Pour LA Flamme DE Veille Présence d’air dans la canalisation de gazProduction Constante D’ÉTINCELLES, Sans Circulation D’EAU Flamme DE Veille ALLUMÉE, Mais LE Brûleur NE ’ALLUME PASEAU Trop Chaude Température DE L’EAU InsuffisanteFluctuation DE LA Température DE L’EAU Pression de gaz insuffisante Voir les spécifications à laVoir a, Voir le tableau 1,702 000 Composants Internes DU CHAUFFE-EAU WR ET Liste DES Pièces703 406 Composants Internes ET Liste DES Pièces Page

WR430-3K specifications

The Bosch Appliances WR430-3K is a high-performance wall oven that exemplifies modern design and cutting-edge technology. Engineered with precision, this appliance is crafted to enhance your cooking experience while seamlessly blending into any kitchen aesthetic.

One of the most notable features of the WR430-3K is its advanced European design that creates a sleek and sophisticated look, making it an attractive addition to any home. The stainless-steel finish not only provides a professional appearance but is also resistant to fingerprints, ensuring that the oven maintains its pristine look over time.

Equipped with Bosch's innovative oven technology, the WR430-3K boasts a convection cooking system that circulates heat evenly throughout the oven cavity. This ensures that every dish cooks uniformly, eliminating hot spots and allowing for perfectly baked goods and evenly roasted meats. The appliance also includes multiple cooking modes such as Bake, Broil, and Roast, providing versatility for a wide range of culinary tasks.

In addition to its cooking prowess, the WR430-3K features Bosch's EcoClean technology which simplifies the cleaning process. The oven interior is coated with a special catalytic material that absorbs grease and reduces the need for harsh cleaning chemicals. This commitment to easy maintenance not only saves time but also contributes to a more environmentally friendly kitchen.

Safety is a priority, and the WR430-3K is equipped with an automatic shut-off feature that provides peace of mind, ensuring that the oven will turn off after a designated period of inactivity. Furthermore, the oven’s control panel is intuitively designed, allowing for effortless navigation through various settings, making it user-friendly for even the least experienced cooks.

The Bosch Appliances WR430-3K also comes with a spacious oven capacity, accommodating large meals and multiple dishes at once. The oven's adjustable racks and several shelf positions allow for flexible cooking arrangements to fit any recipe.

In summary, the Bosch Appliances WR430-3K wall oven combines elegance with functionality. Its impressive features, innovative technologies, and thoughtful design make it an essential appliance for aspiring chefs and home cooks alike, ensuring delicious outcomes for every meal. Whether you are baking, roasting, or broiling, this wall oven is sure to enhance your culinary creations while effortlessly complementing your kitchen decor.