Bradford-White Corp IGE-199C Series, IGE-199R Series Section V Water Connections, Water Quality

Page 11

SECTION V: WATER CONNECTIONS

WARNING

Failure to install and maintain a new, listed pressure relief valve will release the manufacturer from any claim, which might result from excessive temperature and pressures.

Keep clear of the pressure relief valve discharge line outlet. The discharge may be hot enough to cause scald injury. The water is under pressure and may splash.

WARNING

DO NOT reverse the inlet and outlet (cold and hot water) connections on the water heater. This may cause a hazardous operating condition or the water heater may be inoperable

WATER QUALITY

The EVERHOTwater heater must have the water quality within the following limits for long life and reliable operation (see Table 2). The water supply should be tested to make sure the quality is within the specified limits. If there is a problem with the water quality, contact your local water conditioning company for equipment to condition the water supply to this appliance.

NOTICE

Operating this water heater with water conditions outside the specified limits will void the warranty.

Table 2

 

 

TDS

Total

 

 

 

 

 

 

Description

pH

(Total

Aluminum

Chlorides

Copper

Iron

Manganese

Zinc

Dissolved

Hardness

 

 

 

 

 

 

 

 

 

 

Solids)

 

 

 

 

 

 

 

 

 

 

Up to

 

 

 

 

 

 

Levels

6.5 to

Up to 500

200 ppm

Up to 0.2

Up to

Up to

Up to

Up to 0.05

Up to

or 11.7

0.3

8.5

ppm

ppm

250 ppm

1.0 ppm

ppm

5 ppm

 

grains of

ppm

 

 

 

 

 

 

 

 

 

 

 

hardness

 

 

 

 

 

 

Lime Condition Warning Signal:

If the EVERHOT water heater is operated under hard water conditions without a water conditioner, the error code “LC” may flash on the remote temperature display. This code means the heat exchanger coil is beginning to accumulate scale deposits and MUST be flushed (see Section IX, “Flushing Procedure for Lime Scale Removal…”). Contact your installer for a qualified service technician to flush the heat exchanger. A water conditioner may be needed to prevent this condition from reoccurring.

NOTICE

Failure to flush the appliance when “LC” is flashing will cause damage to the heat exchanger. Damage caused by lime or scale build up is not covered by the water heater warranty.

INSTRUCTIONS FOR CONNECTIONS

1.BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE. After shutting off the main water supply, open a faucet to relieve the water line pressure to prevent any water from leaking out of the pipes while making the water connections to the water heater. The COLD water inlet and HOT water outlet are identified on the bottom casing of the water heater. Make the proper plumbing connections between the water heater and the plumbing system to the house. All soldering materials and piping must be compatible with potable water. Unions should be installed on both the hot and cold water lines for future servicing and disconnection of the water heater. Install a shut-off valve in the cold water supply line.

11

Image 11
Contents IGE-199R and IGE-199C Model Series Table of Contents Page Do not Operate the Appliance Until the Leakage is Corrected IGE-199R-10X Section II SpecificationsEVERHOT→ IGE Model Series Dimensions Section III General Information FeaturesDo not Operate the Appliance Until the Leakage is Corrected Section IV Installation InstructionsWater Heater Location UnpackingMount Water Heater on the Wall Build Opening Clearances FigReference Description Minimum Distance Inches cm Remove CartonInstructions for Connections Lime Condition Warning SignalSection V Water Connections Water QualityPage Recommended Piping for a Basic Installation Drain Solenoid Piping Fig Recommended Piping for Power Failure Freeze ProtectionRecommended Piping for a Circulation System Page Pressure Relief Valve Section VI GAS Connections Never USE a Match or Open Flame for TestingGAS Pressure Regulation Initial Operation and Testing Installer onlyGAS Meter Size -NATURALGAS only Page Section VII Electrical Connections Wiring Diagram Wiring Diagram Schematic Residential Models Remote Temperature ControlsEndless hot water system Commercial Models Initial Operation and Testing of Controls Installer only Control Wiring Connections Inside Water HeaterSequence of Operation Section Viii Operating InstructionsTo Fill the Water Heater Manual Gas Valve Fig To Turn OFF GAS to the ApplianceResidential Models see Figure Turning OFF the Water Heater for AN Extended Period of TimeControl For Residential Models Fig Control for Commercial Models Fig Commercial Models see FigureScalding First AID for Scalds Approximate TIME/TEMPERATURE Relationships in ScaldsError Messages on Remote Temperature Control Display Burner Flame Appearance Fig Section IX MaintenancePage Lime Scale Flushing Diagram Fig Schematic Diagram of Internal Parts Section X Parts List Internal Components Internal Components Electrical Components Parts List Anti-Frost Heater Clip

IGE-199R Series, IGE-199C Series specifications

Bradford-White Corporation is a renowned manufacturer in the water heating industry, providing high-quality solutions for residential and commercial applications. Among its innovative line of products, the IGE-199R and IGE-199C Series stand out for their exceptional performance and efficiency in delivering hot water.

The IGE-199R and IGE-199C Series are powered by advanced technology designed to meet the demands of both modern homes and commercial settings. They feature advanced tankless water heating systems that offer continuous hot water on demand, eliminating the need for bulky storage tanks. This not only saves space but also enhances energy efficiency, as hot water is produced only when needed.

One of the key features of the IGE-199R and IGE-199C is their Energy Star certification, attesting to their high efficiency. These units utilize a powerful, high-efficiency condensing heat exchanger, which maximizes heat transfer while minimizing energy loss. The design facilitates a uniform and solid flow rate, ensuring that multiple outlets can be served simultaneously without compromising performance.

Both series also incorporate cutting-edge technology, such as modulating gas burners that adjust the heat output to match the hot water demand. This means that these units can efficiently operate at varying levels of energy consumption, ultimately resulting in lower utility bills for the consumer. Additionally, the units are equipped with an integrated control system that monitors system performance and provides digital diagnostics, making maintenance and troubleshooting straightforward.

Safety features are also paramount in the design of the IGE-199R and IGE-199C models. The units are outfitted with a range of safety sensors, including temperature and pressure relief valves, ensuring safe operation and preventing potential hazards. Furthermore, the innovative venting options allow for flexible installation, even in tight spaces, without compromising safety or efficiency.

The IGE-199R and IGE-199C Series are engineered to be user-friendly, offering a clear interface for easy operation and monitoring. Their robust construction ensures durability and reliability, making them an excellent choice for long-term investment in hot water solutions.

In summary, Bradford-White's IGE-199R and IGE-199C Series deliver exceptional quality and performance in tankless water heating. With their focus on energy efficiency, advanced technologies, and safety features, these units provide a reliable and effective solution for meeting the hot water needs of any household or commercial space.