4.Turn power on (after completing electrical connections – refer to Section VII, “Electrical Connections”) and fully open a hot water tap.

5.Measure the gas pressures to see that these are within the specified limits below:

Supply Pressure:

Nat. Gas: Min.: 6”, Max.: 10.5” w.c.

 

L.P. Gas: Min.: 10”, Max.: 13.5” w.c.

Manifold Pressure:

Nat. Gas: 3.4” w.c. High Fire,

0.6” w.c. Low Fire

 

L.P. Gas: 5.1” w.c. High Fire,

0.9” w.c. Low Fire

6.Turn off the hot water faucets. Disconnect the electrical power to the water heater. Remove the pressure gauges and replace the plugs. Check for gas leaks around the plugs.

7.Replace the front control panel. Restore electrical power to the water heater.

NOTICE

If the gas supply pressure is below the specified value, check the gas piping to insure that it is the correct size for all the gas appliances on line. Check the supply pressure with all the gas appliances in operation. The manifold pressure will vary with the water flow rate. Several hot water faucets may need to be opened with the temperature control set on the highest setting in order to get maximum high fire manifold pressure. If the manifold pressure is below the specified value and there is sufficient water pressure and flow, be sure the inlet gas pressure is within the specified limits before attempting to adjust the manifold pressure.

20

Image 20
Contents IGE-199R and IGE-199C Model Series Table of Contents Page Do not Operate the Appliance Until the Leakage is Corrected Section II Specifications IGE-199R-10XEVERHOT→ IGE Model Series Dimensions Features Section III General InformationSection IV Installation Instructions Do not Operate the Appliance Until the Leakage is CorrectedUnpacking Water Heater LocationBuild Opening Clearances Fig Reference Description Minimum Distance Inches cmRemove Carton Mount Water Heater on the WallLime Condition Warning Signal Section V Water ConnectionsWater Quality Instructions for ConnectionsPage Recommended Piping for a Basic Installation Recommended Piping for Power Failure Freeze Protection Drain Solenoid Piping FigRecommended Piping for a Circulation System Page Pressure Relief Valve Never USE a Match or Open Flame for Testing Section VI GAS ConnectionsGAS Pressure Regulation Initial Operation and Testing Installer onlyGAS Meter Size -NATURALGAS only Page Section VII Electrical Connections Wiring Diagram Wiring Diagram Schematic Remote Temperature Controls Residential ModelsEndless hot water system Commercial Models Control Wiring Connections Inside Water Heater Initial Operation and Testing of Controls Installer onlySequence of Operation Section Viii Operating InstructionsTo Fill the Water Heater To Turn OFF GAS to the Appliance Manual Gas Valve FigTurning OFF the Water Heater for AN Extended Period of Time Residential Models see FigureControl For Residential Models Fig Commercial Models see Figure Control for Commercial Models FigScalding First AID for Scalds Approximate TIME/TEMPERATURE Relationships in ScaldsError Messages on Remote Temperature Control Display Section IX Maintenance Burner Flame Appearance FigPage Lime Scale Flushing Diagram Fig Schematic Diagram of Internal Parts Section X Parts List Internal Components Internal Components Electrical Components Parts List Anti-Frost Heater Clip

IGE-199R Series, IGE-199C Series specifications

Bradford-White Corporation is a renowned manufacturer in the water heating industry, providing high-quality solutions for residential and commercial applications. Among its innovative line of products, the IGE-199R and IGE-199C Series stand out for their exceptional performance and efficiency in delivering hot water.

The IGE-199R and IGE-199C Series are powered by advanced technology designed to meet the demands of both modern homes and commercial settings. They feature advanced tankless water heating systems that offer continuous hot water on demand, eliminating the need for bulky storage tanks. This not only saves space but also enhances energy efficiency, as hot water is produced only when needed.

One of the key features of the IGE-199R and IGE-199C is their Energy Star certification, attesting to their high efficiency. These units utilize a powerful, high-efficiency condensing heat exchanger, which maximizes heat transfer while minimizing energy loss. The design facilitates a uniform and solid flow rate, ensuring that multiple outlets can be served simultaneously without compromising performance.

Both series also incorporate cutting-edge technology, such as modulating gas burners that adjust the heat output to match the hot water demand. This means that these units can efficiently operate at varying levels of energy consumption, ultimately resulting in lower utility bills for the consumer. Additionally, the units are equipped with an integrated control system that monitors system performance and provides digital diagnostics, making maintenance and troubleshooting straightforward.

Safety features are also paramount in the design of the IGE-199R and IGE-199C models. The units are outfitted with a range of safety sensors, including temperature and pressure relief valves, ensuring safe operation and preventing potential hazards. Furthermore, the innovative venting options allow for flexible installation, even in tight spaces, without compromising safety or efficiency.

The IGE-199R and IGE-199C Series are engineered to be user-friendly, offering a clear interface for easy operation and monitoring. Their robust construction ensures durability and reliability, making them an excellent choice for long-term investment in hot water solutions.

In summary, Bradford-White's IGE-199R and IGE-199C Series deliver exceptional quality and performance in tankless water heating. With their focus on energy efficiency, advanced technologies, and safety features, these units provide a reliable and effective solution for meeting the hot water needs of any household or commercial space.