Bradford-White Corp IGE-199R Series Section Viii Operating Instructions, To Fill the Water Heater

Page 28

SECTION VIII: OPERATING INSTRUCTIONS

WARNING

Water heaters are heat-producing appliances. To avoid damage or injury there must be no materials stored against the water heater or near the front vent outlet, and proper care must be taken to avoid unnecessary contact (especially by children) with the water heater and front vent outlet. UNDER NO CIRCUMSTANCES SHOULD FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF THIS WATER HEATER OR IN ANY LOCATION FROM WHICH FUMES COULD REACH THE WATER HEATER.

Installation or service of this water heater requires ability equivalent to that of a licensed tradesman in the field involved. Plumbing, air supply, venting, gas supply and electrical work are required.

Light the unit in accordance with the operating instructions label attached to the water heater.

Under no circumstances should the input rate exceed the input rate shown on the water heater rating plate. Over firing could result in damage or sooting of the water heater.

If the unit is exposed to the following, do not operate water heater until all corrective steps have been made by a factory authorized independent service contractor or qualified service professional.

1.Flooding to or above the level of the burner or controls

2.External firing

3.Damage

4.Firing without water

5.Sooting

NEVER OPERATE THE WATER HEATER WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER AND A PRESSURE RELIEF VALVE IS INSTALLED IN THE HOT WATER OUTLET PIPING OF THE WATER HEATER.

GENERAL INSTRUCTIONS

TO FILL THE WATER HEATER

1.Close the water heater drain valve by turning the knob or valve stem clockwise.

2.Open the cold water supply shut-off valve.

3.Open several hot water faucets to allow air to escape from the system.

4.When a steady stream of water flows from the faucets, the water heater is filled. Close the faucets and check for water leaks at the water heater drain valve, pressure relief valve and the hot and cold water connections.

SEQUENCE OF OPERATION

1.The water heater senses the minimum operating water flow which starts the ignition sequence to light the burners.

2.Blower ON.

3.Pressure switch proves blower operation.

4.Gas valve opens and spark igniter starts.

5.Main burner ON.

6.Flame signal confirmed.

7.Burner flame and combustion blower modulates to maintain selected outlet temperature.

8.Water flow is also regulated to not exceed the capacity of the water heater for the temperature selected.

9.Water flow shuts off.

10.Burners shut off immediately, but combustion blower continues for another 65 seconds to purge heat from coil.

28

Image 28
Contents IGE-199R and IGE-199C Model Series Table of Contents Page Do not Operate the Appliance Until the Leakage is Corrected Section II Specifications IGE-199R-10XEVERHOT→ IGE Model Series Dimensions Features Section III General InformationSection IV Installation Instructions Do not Operate the Appliance Until the Leakage is CorrectedUnpacking Water Heater LocationBuild Opening Clearances Fig Reference Description Minimum Distance Inches cmRemove Carton Mount Water Heater on the WallLime Condition Warning Signal Section V Water ConnectionsWater Quality Instructions for ConnectionsPage Recommended Piping for a Basic Installation Recommended Piping for Power Failure Freeze Protection Drain Solenoid Piping FigRecommended Piping for a Circulation System Page Pressure Relief Valve Never USE a Match or Open Flame for Testing Section VI GAS ConnectionsGAS Meter Size -NATURALGAS only Initial Operation and Testing Installer onlyGAS Pressure Regulation Page Section VII Electrical Connections Wiring Diagram Wiring Diagram Schematic Remote Temperature Controls Residential ModelsEndless hot water system Commercial Models Control Wiring Connections Inside Water Heater Initial Operation and Testing of Controls Installer onlyTo Fill the Water Heater Section Viii Operating InstructionsSequence of Operation To Turn OFF GAS to the Appliance Manual Gas Valve FigTurning OFF the Water Heater for AN Extended Period of Time Residential Models see FigureControl For Residential Models Fig Commercial Models see Figure Control for Commercial Models FigScalding Error Messages on Remote Temperature Control Display Approximate TIME/TEMPERATURE Relationships in ScaldsFirst AID for Scalds Section IX Maintenance Burner Flame Appearance FigPage Lime Scale Flushing Diagram Fig Schematic Diagram of Internal Parts Section X Parts List Internal Components Internal Components Electrical Components Parts List Anti-Frost Heater Clip

IGE-199R Series, IGE-199C Series specifications

Bradford-White Corporation is a renowned manufacturer in the water heating industry, providing high-quality solutions for residential and commercial applications. Among its innovative line of products, the IGE-199R and IGE-199C Series stand out for their exceptional performance and efficiency in delivering hot water.

The IGE-199R and IGE-199C Series are powered by advanced technology designed to meet the demands of both modern homes and commercial settings. They feature advanced tankless water heating systems that offer continuous hot water on demand, eliminating the need for bulky storage tanks. This not only saves space but also enhances energy efficiency, as hot water is produced only when needed.

One of the key features of the IGE-199R and IGE-199C is their Energy Star certification, attesting to their high efficiency. These units utilize a powerful, high-efficiency condensing heat exchanger, which maximizes heat transfer while minimizing energy loss. The design facilitates a uniform and solid flow rate, ensuring that multiple outlets can be served simultaneously without compromising performance.

Both series also incorporate cutting-edge technology, such as modulating gas burners that adjust the heat output to match the hot water demand. This means that these units can efficiently operate at varying levels of energy consumption, ultimately resulting in lower utility bills for the consumer. Additionally, the units are equipped with an integrated control system that monitors system performance and provides digital diagnostics, making maintenance and troubleshooting straightforward.

Safety features are also paramount in the design of the IGE-199R and IGE-199C models. The units are outfitted with a range of safety sensors, including temperature and pressure relief valves, ensuring safe operation and preventing potential hazards. Furthermore, the innovative venting options allow for flexible installation, even in tight spaces, without compromising safety or efficiency.

The IGE-199R and IGE-199C Series are engineered to be user-friendly, offering a clear interface for easy operation and monitoring. Their robust construction ensures durability and reliability, making them an excellent choice for long-term investment in hot water solutions.

In summary, Bradford-White's IGE-199R and IGE-199C Series deliver exceptional quality and performance in tankless water heating. With their focus on energy efficiency, advanced technologies, and safety features, these units provide a reliable and effective solution for meeting the hot water needs of any household or commercial space.