SECTION VII
OPERATING INSTRUCTIONS
WARNING
Water heaters are
UNDER NO CIRCUMSTANCES SHALL FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF THE WATER HEATER OR IN ANY LOCATION FROM WHICH FUMES COULD REACH THE WATER HEATER.
Installation or service of this water heater requires ability equivalent to that of a licensed tradesman in the field involved. Plumbing and electrical work are required.
SYSTEM START-UP
Follow boiler installation instructions to place boiler in operation.
SEQUENCE OF OPERATIONS
1.Aquastat senses stored water temperature drops below desired setting.
a.Domestic hot water priority only: Normally closed contacts open to interrupt space heating.
2.Aquastat satisfied.
a.Aquastat contacts open, turning off domestic hot water circulator and
b.Normally open contacts open, stopping boiler operation.
c.Domestic hot water priority only: Normally closed contacts close, returning boiler control to space heating.
37