| TROUBLESHOOTING GUIDE |
|
|
| ||
| Symptom |
| Probable Cause |
| Corrective Action | |||||||
|
|
| ||||||||||
| Water reaches 180°F (82°C) but |
| Low incoming water temperature. |
| Incoming water temperature must be adequate |
|
| |||||
| does not last through the entire |
|
|
|
|
| for booster size. Increase incoming water | |||||
| dishwasher operation. |
|
|
|
|
| temperature. | |||||
|
|
| Incoming water temperature drops. | Primary water supply is not adequate to provide |
|
|
| |||||
|
|
|
|
|
|
| correct temperature in sufficient quantities. | |||||
|
|
|
|
|
|
| Increase supply of primary hot water. | |||||
|
|
|
|
|
|
|
|
|
| |||
|
|
| Flow pressure is too high. |
|
| Higher pressure uses an excessive quantity of hot | ||||||
|
|
|
|
|
|
| water. Adjust flow pressure to 20 psi (138 kPa). | |||||
|
|
| Booster water heater may be | Booster water heater must be sized properly for |
| |||||||
|
|
| undersized. |
|
|
| incoming water temperature and rinse | |||||
|
|
|
|
|
|
| requirements of the dish machine. | |||||
|
|
| Incorrect voltage. |
|
| Check voltage on heater serial plate and make | ||||||
|
|
|
|
|
|
| sure supplied voltage matches. A 240 V booster | |||||
|
|
|
|
|
|
| water heater operating on 208 V reduces wattage | |||||
|
|
|
|
|
|
| to 76% of the normal output. | |||||
| The booster heater does not heat |
| Unit may have been energized | This will cause the elements to burn out quickly. |
|
|
| |||||
| at all or only delivers water at |
| without water (dry fired). |
|
| Replace the element(s). | ||||||
|
|
|
|
|
|
| ||||||
|
| Fuses may be blown or circuit | Check for proper fuse sizing. Replace fuses. | |||||||||
|
|
| breaker tripped. |
|
|
| Check/reset circuit breaker. | |||||
|
|
|
| Contact Authorized Service Agent or Bradford |
| |||||||
|
|
|
|
|
|
| White for assistance. | |||||
|
|
| Temperature | setting | out | of | Temperature setting should be maximum | |||||
|
|
| calibration or inoperable. |
|
| of 190°F (88°C). | ||||||
|
|
| Contactors do not pull in. |
|
| Contact Authorized Service Agent or Bradford |
|
| ||||
|
|
|
|
|
|
| White for assistance. | |||||
|
|
| High limit switch may be tripped or | Reset switch. If switch continues to trip or cannot |
|
|
| |||||
|
|
| defective. |
|
|
| be reset contact an Authorized Service Agent. | |||||
|
|
| Transformer not working properly. |
| Contact Authorized Service Agent or Bradford |
|
|
| ||||
|
|
|
|
|
|
| White for assistance. | |||||
|
|
| Low water cutoff inoperable, |
| Contact Authorized Service Agent or Bradford | |||||||
|
|
| contacts do not close. |
|
| White for assistance. |
Form No. | 15 |