Bradford-White Corp TG-150I-N(X) Lighting Instructions For Your Safety Read Before Operating

Page 61

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing

property damage, personal injury or loss of life.

A. This water heater does not have a

Immediately call your gas supplier from a

 

pilot. It is equipped with a direct

 

neighbor’s phone. Follow the gas supplier’s

 

ignition device, which automatically

 

instructions.

 

lights the burner. Do not try to light

If you cannot reach your gas supplier, call the fire

 

the burner by hand.

 

department.

B.

BEFORE OPERATING: Smell all

C.

Use only your hand to operate the remote control

 

around the appliance area for gas.

 

keypad. Never use tools. If the remote keypad

 

Be sure to smell next to the floor,

 

doesn’t work, do not try to repair it, call a qualified

 

because some gas is heavier than

 

service technician. Forced or improper repair

 

air and will settle on the floor.

 

may result in a fire or explosion.

WHAT TO DO IF YOU SMELL GAS

D.

Do not use this water heater if any part has been

Do not try to light any appliance.

 

under water. Immediately call a qualified service

Do not touch any electric switch; do

 

technician to inspect the water heater and to

 

not use any phone in your building.

 

replace any part of the control system and any

 

 

 

gas control which has been under water.

OPERATION INSTRUCTIONS

1.STOP! Read the safety information above before proceeding.

2.Set the thermostat to the lowest setting.

3.Turn off all power to the electrical appliance.

4.This water heater does not have a pilot. It is equipped with a direct ignition device, which automatically lights the burner. Do not try to light the burner by hand.

5.Turn the manual valve located at the gas inlet of the appliance clockwise to “OFF” (See Figure ).

6.Wait (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to next step.

7.Turn the manual valve located at the gas inlet of

appliance counterclockwise to “ON” (See Figure ).

8.Turn on all electric power to the appliance.

9.Set the thermostat to desired setting.

10.If the appliance will not operate, Follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.

TO TURN OFF GAS TO THE APPLIANCE

1.Set the thermostat to the lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3.Turn the manual valve at gas inlet of appliance

clockwise to “OFF” (See Figure ).

Figure 47. Manual Gas Valve.

61

Image 61
Contents TG-150I-NX, TG-180I-NX, TG-199I-NX, TG237I-NX & TG-237I-NXA Table of Contents Page Page If YOU Smell GAS Model Section II SpecificationsDimensions 10.0 Section III Installation Instructions Water Heater Location UnpackingRemove Carton Mount Water Heater on the Wall Important In the State of Massachusetts 248CMR 4.00 State RegulationsWater Quality Section IV Water ConnectionsInstructions for Connections Page Approximate TIME/TEMPERATURE Relationships in Scalds Recommended Piping for a Basic Installation Recommended Piping for a Circulation Systems Recommended Piping for Freeze Protection Recommended Piping for Power Failure Freeze ProtectionPressure Relief Valve Page Page Section V Venting Venting Direct Vent Terminal Location Vent / Air Intake Terminal LocationsVenting System Layout Venting System InstallationHorizontal Direct Vent Installations Prior to the Installation of the EverHot Direct Vent SystemPage Vertical Vent Installations Vertical Direct Vent InstallationsDip Switch Combustion Blower Dip Switch SettingsInstallation of Venting System Components Recommended Vent/Air Intake Terminal Position CondensateCoping with Condensation Joint ConnectionShortening of Vent Extensions Condensate DrainComponents Needed for Direct Vent Applications Venting Parts & DimensionsVent Pipe Clamp, p/n Page Illustration Showing How to Properly Cut a Vent Extension Measure Dimension to FitFinal Installation of the Vent System Cut the Vent to Fit Illustration Showing How to Cut the Vertical Vent to FitMounting the Vent System Vertical Discharge Direct Vent Installation TG-237IModels OnlyHorizontal Discharge for TG-237IModels Illustration Showing the Installation of the Air IntakePage High Altitude Installations Page Venting Suppliers Adjustable Horizontal Concentric TerminationManufacturer Product Manufacturer Product Appliance Vertical Horizontal AdapterSection VI GAS Connections GAS Pressure Regulation GAS Meter Size Natural GAS onlyGas Specific CorrectionInitial Operation and Testing Installer only Section VII Electrical Connections CPU Page Wiring Diagram for TG-237I-NXand TG-237I-NXAModels Temperature Controls Page Installation of Remote Controls Optional Indicator ThermostatIllustration Showing Where to Connect Remote Control Harness Troubleshooting Electrical Initial Operation and Testing of Controls Installer onlyWire Color Resistance Connector Pin NosFlame Rod Heat Exchanger and Outgoing Water Temperature ThermistorsAmp Fuses Frost ProtectionGeneral Instructions To Fill the Water Heater Section Viii Operating InstructionsSequence of Operation Property damage, personal injury or loss of life Lighting Instructions For Your Safety Read Before OperatingWhat to do if YOU Smell GAS Operation InstructionsTurning OFF the Water Heater for AN Extended Period of Time Temperature AdjustmentTemperature Display Use Indicator Scalding Approximate TIME/TEMPERATURE Relationships in ScaldsCode Code Description First AID for ScaldsCode Code Description Flame Failure Code Burner Flame Appearance Section IX MaintenancePage Water Heater Circulating PumpPage Section X Parts List Description Quantity Page Description Quantity Page Description Quantity Page Description Quantity TG-237I Models TG-237I-N TG-237I-X TG-237I-NA TG-237I-XA Page Description Quantity Page Description Quantity Page Description Quantity Section XI Warranty How do you get warranty assistance? What will we do to correct problems?What should you do to keep the warranty in effect? What will we not do?Page Page Fax/215-641-1670 Parts Fax/215-641-2180

TG-199I-N(X), TG-237I-N(X)A, TG-150I-N(X), TG237I-N(X), TG-180I-N(X) specifications

Bradford White Corp, a leader in water heating, offers a range of innovative water heaters, including the TG-180I-N(X), TG-237I-N(X), TG-150I-N(X), TG-237I-N(X)A, and TG-199I-N(X) models. These units are designed to deliver energy-efficient performance while ensuring reliability and ease of use for both residential and commercial applications.

One of the main features of the TG series is their robust design, which is built to withstand the rigors of daily use. These models are equipped with a durable steel tank that is glass-lined to prevent corrosion, ensuring a longer lifespan and reduced maintenance needs. The insulation system utilized in these water heaters is designed to minimize heat loss, contributing to overall energy efficiency.

In terms of technology, the TG series utilizes advanced gas burner systems that ensure optimal heating performance. The models feature an atmospheric venting system that is simple to install and maintain, offering great flexibility in terms of placement within a building. Additionally, the inclusion of Bradford White's signature Hydrojet® Total Performance System enhances overall efficiency by reducing sediment buildup, allowing for better heat transfer and increased performance.

Each model in this range is designed with user-friendly controls. The intuitive thermostat settings enable users to easily adjust the water temperature to meet their specific needs. Moreover, these water heaters incorporate safety features such as high-temperature limit switches and a temperature and pressure relief valve, ensuring safe operation.

Another important characteristic of these models is their compliance with industry standards. The TG series meets or exceeds the stringent guidelines set forth by the American National Standards Institute (ANSI) and the National Sanitation Foundation (NSF), demonstrating Bradford White's commitment to quality and safety.

Moreover, the TG series is designed to be environmentally friendly, incorporating features that support lower emissions and energy consumption. By using high-efficiency burners and improved insulation, these models contribute to reduced greenhouse gas emissions, aligning with global sustainability goals.

In summary, the Bradford White Corp TG-180I-N(X), TG-237I-N(X), TG-150I-N(X), TG-237I-N(X)A, and TG-199I-N(X) water heaters are engineered for efficiency, durability, and safety. With advanced features and technologies, they provide reliable hot water solutions for a variety of settings, making them an excellent choice for consumers seeking high-quality water heating options.