Bradford-White Corp TG-180I-N(X), TG237I-N(X), TG-150I-N(X), TG-237I-N(X)A Description Quantity

Page 77

 

 

TG-199I-N

TG-199I-X

TG-180I-N

TG-180I-X

TG-150I-N

TG-150I-X

 

 

 

 

 

 

 

 

No

Description

 

 

Quantity

 

 

100

Gas Control Assembly

1

1

1

1

1

1

101

Blind Screw

2

2

2

2

2

2

102

3/4 Gas Inlet

1

1

1

1

1

1

 

 

 

 

 

 

 

 

400

3/4 Water Inlet B

1

1

1

1

1

1

401

Water Flow Servo & Sensor Assembly

1

1

 

 

 

 

401

Water Flow Servo & Sensor Assembly

 

 

1

1

1

1

402

Rectifier

1

1

1

1

1

1

403

By-pass Servo Assembly

1

1

-

-

-

-

404

Stop Bracket

2

2

-

-

-

-

404

Stop Bracket

-

-

1

1

1

1

405

Plug Band

1

1

1

1

1

1

408

3/4 Hot Water Outlet

1

1

1

1

1

1

409

Stop Bracket

1

1

1

1

1

1

410

Plug Band (small)

1

1

1

1

1

1

411

Drain Valve

1

1

1

1

1

1

412

Filter Plug Assembly

1

1

1

1

1

1

413

Cover

1

1

1

1

1

1

 

 

 

 

 

 

 

 

700

Electric Unit Assembly

1

1

-

-

-

-

700

Electric Unit Assembly

-

-

1

1

1

1

701

Surge Protector

1

1

1

1

1

1

702

Electric Unit Cover

1

1

1

1

1

1

703

EC Cover

1

1

1

1

1

1

727

MR Sensor

1

1

1

1

1

1

730

Thermistor

1

1

1

1

1

1

 

 

 

 

 

 

 

 

804

Thermistor Stop Screw

1

1

1

1

1

1

805

Screw

3

3

2

2

2

2

807

Resin Washer

2

2

2

2

2

2

810

O-ring

2

2

2

2

2

2

813

O-ring

2

2

1

1

1

1

814

O-ring

2

2

2

2

2

2

815

O-ring

2

2

1

1

1

1

816

O-ring

1

1

1

1

1

1

817

O-ring

1

1

1

1

1

1

818

Packing

2

2

2

2

2

2

819

Screw

2

2

2

2

2

2

820

Screw

4

4

4

4

4

4

821

Screw

2

2

2

2

2

2

822

Screw

3

3

3

3

3

3

77

Image 77
Contents TG-150I-NX, TG-180I-NX, TG-199I-NX, TG237I-NX & TG-237I-NXA Table of Contents Page Page If YOU Smell GAS Model Section II SpecificationsDimensions 10.0 Section III Installation Instructions Remove Carton UnpackingWater Heater Location Mount Water Heater on the Wall Important In the State of Massachusetts 248CMR 4.00 State RegulationsInstructions for Connections Section IV Water ConnectionsWater Quality Page Approximate TIME/TEMPERATURE Relationships in Scalds Recommended Piping for a Basic Installation Recommended Piping for a Circulation Systems Recommended Piping for Freeze Protection Recommended Piping for Power Failure Freeze ProtectionPressure Relief Valve Page Page Section V Venting Venting Direct Vent Terminal Location Vent / Air Intake Terminal LocationsVenting System Layout Venting System InstallationHorizontal Direct Vent Installations Prior to the Installation of the EverHot Direct Vent SystemPage Vertical Vent Installations Vertical Direct Vent InstallationsDip Switch Combustion Blower Dip Switch SettingsInstallation of Venting System Components Recommended Vent/Air Intake Terminal Position CondensateCoping with Condensation Joint ConnectionShortening of Vent Extensions Condensate DrainComponents Needed for Direct Vent Applications Venting Parts & DimensionsVent Pipe Clamp, p/n Page Illustration Showing How to Properly Cut a Vent Extension Measure Dimension to FitFinal Installation of the Vent System Cut the Vent to Fit Illustration Showing How to Cut the Vertical Vent to FitMounting the Vent System Vertical Discharge Direct Vent Installation TG-237IModels OnlyHorizontal Discharge for TG-237IModels Illustration Showing the Installation of the Air IntakePage High Altitude Installations Page Venting Suppliers Adjustable Horizontal Concentric TerminationManufacturer Product Manufacturer Product Appliance Vertical Horizontal AdapterSection VI GAS Connections GAS Pressure Regulation GAS Meter Size Natural GAS onlyGas Specific CorrectionInitial Operation and Testing Installer only Section VII Electrical Connections CPU Page Wiring Diagram for TG-237I-NXand TG-237I-NXAModels Temperature Controls Page Installation of Remote Controls Optional Indicator ThermostatIllustration Showing Where to Connect Remote Control Harness Troubleshooting Electrical Initial Operation and Testing of Controls Installer onlyWire Color Resistance Connector Pin NosFlame Rod Heat Exchanger and Outgoing Water Temperature ThermistorsAmp Fuses Frost ProtectionSequence of Operation Section Viii Operating InstructionsGeneral Instructions To Fill the Water Heater Property damage, personal injury or loss of life Lighting Instructions For Your Safety Read Before OperatingWhat to do if YOU Smell GAS Operation InstructionsTurning OFF the Water Heater for AN Extended Period of Time Temperature AdjustmentTemperature Display Use Indicator Scalding Approximate TIME/TEMPERATURE Relationships in ScaldsCode Code Description First AID for ScaldsCode Code Description Flame Failure Code Burner Flame Appearance Section IX MaintenancePage Water Heater Circulating PumpPage Section X Parts List Description Quantity Page Description Quantity Page Description Quantity Page Description Quantity TG-237I Models TG-237I-N TG-237I-X TG-237I-NA TG-237I-XA Page Description Quantity Page Description Quantity Page Description Quantity Section XI Warranty How do you get warranty assistance? What will we do to correct problems?What should you do to keep the warranty in effect? What will we not do?Page Page Fax/215-641-1670 Parts Fax/215-641-2180

TG-199I-N(X), TG-237I-N(X)A, TG-150I-N(X), TG237I-N(X), TG-180I-N(X) specifications

Bradford White Corp, a leader in water heating, offers a range of innovative water heaters, including the TG-180I-N(X), TG-237I-N(X), TG-150I-N(X), TG-237I-N(X)A, and TG-199I-N(X) models. These units are designed to deliver energy-efficient performance while ensuring reliability and ease of use for both residential and commercial applications.

One of the main features of the TG series is their robust design, which is built to withstand the rigors of daily use. These models are equipped with a durable steel tank that is glass-lined to prevent corrosion, ensuring a longer lifespan and reduced maintenance needs. The insulation system utilized in these water heaters is designed to minimize heat loss, contributing to overall energy efficiency.

In terms of technology, the TG series utilizes advanced gas burner systems that ensure optimal heating performance. The models feature an atmospheric venting system that is simple to install and maintain, offering great flexibility in terms of placement within a building. Additionally, the inclusion of Bradford White's signature Hydrojet® Total Performance System enhances overall efficiency by reducing sediment buildup, allowing for better heat transfer and increased performance.

Each model in this range is designed with user-friendly controls. The intuitive thermostat settings enable users to easily adjust the water temperature to meet their specific needs. Moreover, these water heaters incorporate safety features such as high-temperature limit switches and a temperature and pressure relief valve, ensuring safe operation.

Another important characteristic of these models is their compliance with industry standards. The TG series meets or exceeds the stringent guidelines set forth by the American National Standards Institute (ANSI) and the National Sanitation Foundation (NSF), demonstrating Bradford White's commitment to quality and safety.

Moreover, the TG series is designed to be environmentally friendly, incorporating features that support lower emissions and energy consumption. By using high-efficiency burners and improved insulation, these models contribute to reduced greenhouse gas emissions, aligning with global sustainability goals.

In summary, the Bradford White Corp TG-180I-N(X), TG-237I-N(X), TG-150I-N(X), TG-237I-N(X)A, and TG-199I-N(X) water heaters are engineered for efficiency, durability, and safety. With advanced features and technologies, they provide reliable hot water solutions for a variety of settings, making them an excellent choice for consumers seeking high-quality water heating options.