Bradford-White Corp TG-237I-N(X)A, TG237I-N(X) Section IX Maintenance, Burner Flame Appearance

Page 68

SECTION IX: MAINTENANCE

WARNING

Always turn off the electrical power supply, the manual gas valve, and the manual water control valve whenever servicing this appliance.

KEEP THE WATER HEATER AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS.

The EverHot® water heater should be checked annually by a qualified technician. Regular maintenance will keep the water heater operating efficiently and help to assure reliable operation and a long service life.

1.Remove and clean the inlet water filter screen. If a Y-type strainer or cartridge filter is used on the cold water inlet to the water heater, inspect or clean as needed to assure full water flow to the water heater.

2.Visually inspect the burner flames. The flame must burn with a clear blue, stable flame (possibly with orange tips). Refer to Figure for satisfactory flame appearance. If the burner flame appearance is not satisfactory or debris is visible on the burners, remove and clean with a vacuum cleaner.

Figure 50. Burner Flame Appearance.

3.Inspect entire venting system and vent terminal. Make sure all the venting connections are tight and the gaskets are in good condition. Check the vent terminal openings for blockage and clean, if necessary. Keep shrubs and vegetation clear of the vent terminal.

4.All electric motors are permanently lubricated and do not need oiling. Remove the combustion air blower and clean wheel and housing with soft brush or vacuum.

5.If the “LC” code has been flashing on the display, the heat exchanger will need flushing to remove lime and scale deposits. Refer to the “Flushing Procedure for Lime Scale Removal…” in Section IX, “Maintenance.”

6.Check operation of the pressure relief valve. To check the relief valve, lift the lever at the end of the valve several times. The valve should seat properly and operate freely. If water does not flow, remove and inspect for obstructions or corrosion. Replace with a new valve of the recommended size as necessary. A thorough inspection of the valve should be performed at least every three years by removing the pressure relief valve from the outlet piping. Do not attempt to repair the valve, as this could result in improper operation and explosion of the heat exchanger and piping. In areas with poor water conditions, it may be necessary to inspect the pressure relief valve more often than the recommended maintenance schedule.

68

Image 68
Contents TG-150I-NX, TG-180I-NX, TG-199I-NX, TG237I-NX & TG-237I-NXA Table of Contents Page Page If YOU Smell GAS Section II Specifications ModelDimensions 10.0 Section III Installation Instructions Remove Carton UnpackingWater Heater Location Mount Water Heater on the Wall State Regulations Important In the State of Massachusetts 248CMR 4.00Instructions for Connections Section IV Water ConnectionsWater Quality Page Approximate TIME/TEMPERATURE Relationships in Scalds Recommended Piping for a Basic Installation Recommended Piping for a Circulation Systems Recommended Piping for Power Failure Freeze Protection Recommended Piping for Freeze ProtectionPressure Relief Valve Page Page Section V Venting Venting Vent / Air Intake Terminal Locations Direct Vent Terminal LocationVenting System Installation Venting System LayoutPrior to the Installation of the EverHot Direct Vent System Horizontal Direct Vent InstallationsPage Vertical Direct Vent Installations Vertical Vent InstallationsCombustion Blower Dip Switch Settings Dip SwitchInstallation of Venting System Components Condensate Recommended Vent/Air Intake Terminal PositionJoint Connection Coping with CondensationCondensate Drain Shortening of Vent ExtensionsVenting Parts & Dimensions Components Needed for Direct Vent ApplicationsVent Pipe Clamp, p/n Page Measure Dimension to Fit Illustration Showing How to Properly Cut a Vent ExtensionFinal Installation of the Vent System Illustration Showing How to Cut the Vertical Vent to Fit Cut the Vent to FitDirect Vent Installation TG-237IModels Only Mounting the Vent System Vertical DischargeIllustration Showing the Installation of the Air Intake Horizontal Discharge for TG-237IModelsPage High Altitude Installations Page Adjustable Horizontal Concentric Termination Venting SuppliersManufacturer Product Manufacturer Product Appliance Vertical Horizontal AdapterSection VI GAS Connections GAS Meter Size Natural GAS only GAS Pressure RegulationGas Specific CorrectionInitial Operation and Testing Installer only Section VII Electrical Connections CPU Page Wiring Diagram for TG-237I-NXand TG-237I-NXAModels Temperature Controls Page Indicator Thermostat Installation of Remote Controls OptionalIllustration Showing Where to Connect Remote Control Harness Initial Operation and Testing of Controls Installer only Troubleshooting ElectricalWire Color Resistance Connector Pin NosHeat Exchanger and Outgoing Water Temperature Thermistors Flame RodFrost Protection Amp FusesSequence of Operation Section Viii Operating InstructionsGeneral Instructions To Fill the Water Heater Lighting Instructions For Your Safety Read Before Operating Property damage, personal injury or loss of lifeWhat to do if YOU Smell GAS Operation InstructionsTemperature Adjustment Turning OFF the Water Heater for AN Extended Period of TimeTemperature Display Use Indicator Approximate TIME/TEMPERATURE Relationships in Scalds ScaldingFirst AID for Scalds Code Code DescriptionCode Code Description Flame Failure Code Section IX Maintenance Burner Flame AppearancePage Circulating Pump Water HeaterPage Section X Parts List Description Quantity Page Description Quantity Page Description Quantity Page Description Quantity TG-237I Models TG-237I-N TG-237I-X TG-237I-NA TG-237I-XA Page Description Quantity Page Description Quantity Page Description Quantity Section XI Warranty What will we do to correct problems? How do you get warranty assistance?What should you do to keep the warranty in effect? What will we not do?Page Page Fax/215-641-1670 Parts Fax/215-641-2180

TG-199I-N(X), TG-237I-N(X)A, TG-150I-N(X), TG237I-N(X), TG-180I-N(X) specifications

Bradford White Corp, a leader in water heating, offers a range of innovative water heaters, including the TG-180I-N(X), TG-237I-N(X), TG-150I-N(X), TG-237I-N(X)A, and TG-199I-N(X) models. These units are designed to deliver energy-efficient performance while ensuring reliability and ease of use for both residential and commercial applications.

One of the main features of the TG series is their robust design, which is built to withstand the rigors of daily use. These models are equipped with a durable steel tank that is glass-lined to prevent corrosion, ensuring a longer lifespan and reduced maintenance needs. The insulation system utilized in these water heaters is designed to minimize heat loss, contributing to overall energy efficiency.

In terms of technology, the TG series utilizes advanced gas burner systems that ensure optimal heating performance. The models feature an atmospheric venting system that is simple to install and maintain, offering great flexibility in terms of placement within a building. Additionally, the inclusion of Bradford White's signature Hydrojet® Total Performance System enhances overall efficiency by reducing sediment buildup, allowing for better heat transfer and increased performance.

Each model in this range is designed with user-friendly controls. The intuitive thermostat settings enable users to easily adjust the water temperature to meet their specific needs. Moreover, these water heaters incorporate safety features such as high-temperature limit switches and a temperature and pressure relief valve, ensuring safe operation.

Another important characteristic of these models is their compliance with industry standards. The TG series meets or exceeds the stringent guidelines set forth by the American National Standards Institute (ANSI) and the National Sanitation Foundation (NSF), demonstrating Bradford White's commitment to quality and safety.

Moreover, the TG series is designed to be environmentally friendly, incorporating features that support lower emissions and energy consumption. By using high-efficiency burners and improved insulation, these models contribute to reduced greenhouse gas emissions, aligning with global sustainability goals.

In summary, the Bradford White Corp TG-180I-N(X), TG-237I-N(X), TG-150I-N(X), TG-237I-N(X)A, and TG-199I-N(X) water heaters are engineered for efficiency, durability, and safety. With advanced features and technologies, they provide reliable hot water solutions for a variety of settings, making them an excellent choice for consumers seeking high-quality water heating options.