Bradford-White Corp TG-237I-N(X)A, TG237I-N(X) Condensate Drain, Shortening of Vent Extensions

Page 33

Condensate Drain

Every vent system should utilize the condensate collector unless installed with a total vent length of less than 5 ft (1.52 m). The condensate collector is incorporated into the water heater’s vent connection.

To prevent condensate from draining back to the water heater, the condensate collector and trap should be used. The trap must be inspected annually for obstructions and water content in the trap. Provisions must be made to properly drain and dispose of condensate; be aware that condensate is a highly corrosive substance that could damage metals. The condensate draining hose should be subject to inspection; kinks must be avoided. Dispose of condensate in accordance with local codes. Minimum water level in the condensate trap must be 3 in. (75 mm).

Shortening of Vent Extensions

Figure 17. Illustration Showing How to Shorten Vent Extensions.

The aluminum inside pipe should always extend 0.4 in. (10 mm) beyond the white plastic outside pipe on the male end of the vent extension. Always cut the male end of the vent pipe extension. Do not attempt to cut the female end.

Figure 18. Illustration Showing How to Determine the Length to Cut Off.

Pipes overlap by 2.5 in. (65 mm). Therefore, when cutting to size, add 2.5 in. (65 mm) to the extension pipe length (X) needed for installation. Deburr all sharp edges. Otherwise, the gaskets may get damaged, which can result in the vent system no longer being air tight.

WARNING

Improper installations of vent system and components, or failure to follow all installation instructions, can result in property damage or serious injury.

33

Image 33
Contents TG-150I-NX, TG-180I-NX, TG-199I-NX, TG237I-NX & TG-237I-NXA Table of Contents Page Page If YOU Smell GAS Model Section II SpecificationsDimensions 10.0 Section III Installation Instructions Unpacking Water Heater LocationRemove Carton Mount Water Heater on the Wall Important In the State of Massachusetts 248CMR 4.00 State RegulationsSection IV Water Connections Water QualityInstructions for Connections Page Approximate TIME/TEMPERATURE Relationships in Scalds Recommended Piping for a Basic Installation Recommended Piping for a Circulation Systems Recommended Piping for Freeze Protection Recommended Piping for Power Failure Freeze ProtectionPressure Relief Valve Page Page Section V Venting Venting Direct Vent Terminal Location Vent / Air Intake Terminal LocationsVenting System Layout Venting System InstallationHorizontal Direct Vent Installations Prior to the Installation of the EverHot Direct Vent SystemPage Vertical Vent Installations Vertical Direct Vent InstallationsDip Switch Combustion Blower Dip Switch SettingsInstallation of Venting System Components Recommended Vent/Air Intake Terminal Position CondensateCoping with Condensation Joint ConnectionShortening of Vent Extensions Condensate DrainComponents Needed for Direct Vent Applications Venting Parts & DimensionsVent Pipe Clamp, p/n Page Illustration Showing How to Properly Cut a Vent Extension Measure Dimension to FitFinal Installation of the Vent System Cut the Vent to Fit Illustration Showing How to Cut the Vertical Vent to FitMounting the Vent System Vertical Discharge Direct Vent Installation TG-237IModels OnlyHorizontal Discharge for TG-237IModels Illustration Showing the Installation of the Air IntakePage High Altitude Installations Page Venting Suppliers Adjustable Horizontal Concentric TerminationManufacturer Product Manufacturer Product Appliance Vertical Horizontal AdapterSection VI GAS Connections GAS Pressure Regulation GAS Meter Size Natural GAS onlyGas Specific CorrectionInitial Operation and Testing Installer only Section VII Electrical Connections CPU Page Wiring Diagram for TG-237I-NXand TG-237I-NXAModels Temperature Controls Page Installation of Remote Controls Optional Indicator ThermostatIllustration Showing Where to Connect Remote Control Harness Troubleshooting Electrical Initial Operation and Testing of Controls Installer onlyWire Color Resistance Connector Pin NosFlame Rod Heat Exchanger and Outgoing Water Temperature ThermistorsAmp Fuses Frost ProtectionSection Viii Operating Instructions General Instructions To Fill the Water HeaterSequence of Operation Property damage, personal injury or loss of life Lighting Instructions For Your Safety Read Before OperatingWhat to do if YOU Smell GAS Operation InstructionsTurning OFF the Water Heater for AN Extended Period of Time Temperature AdjustmentTemperature Display Use Indicator Scalding Approximate TIME/TEMPERATURE Relationships in ScaldsCode Code Description First AID for ScaldsCode Code Description Flame Failure Code Burner Flame Appearance Section IX MaintenancePage Water Heater Circulating PumpPage Section X Parts List Description Quantity Page Description Quantity Page Description Quantity Page Description Quantity TG-237I Models TG-237I-N TG-237I-X TG-237I-NA TG-237I-XA Page Description Quantity Page Description Quantity Page Description Quantity Section XI Warranty How do you get warranty assistance? What will we do to correct problems?What should you do to keep the warranty in effect? What will we not do?Page Page Fax/215-641-1670 Parts Fax/215-641-2180

TG-199I-N(X), TG-237I-N(X)A, TG-150I-N(X), TG237I-N(X), TG-180I-N(X) specifications

Bradford White Corp, a leader in water heating, offers a range of innovative water heaters, including the TG-180I-N(X), TG-237I-N(X), TG-150I-N(X), TG-237I-N(X)A, and TG-199I-N(X) models. These units are designed to deliver energy-efficient performance while ensuring reliability and ease of use for both residential and commercial applications.

One of the main features of the TG series is their robust design, which is built to withstand the rigors of daily use. These models are equipped with a durable steel tank that is glass-lined to prevent corrosion, ensuring a longer lifespan and reduced maintenance needs. The insulation system utilized in these water heaters is designed to minimize heat loss, contributing to overall energy efficiency.

In terms of technology, the TG series utilizes advanced gas burner systems that ensure optimal heating performance. The models feature an atmospheric venting system that is simple to install and maintain, offering great flexibility in terms of placement within a building. Additionally, the inclusion of Bradford White's signature Hydrojet® Total Performance System enhances overall efficiency by reducing sediment buildup, allowing for better heat transfer and increased performance.

Each model in this range is designed with user-friendly controls. The intuitive thermostat settings enable users to easily adjust the water temperature to meet their specific needs. Moreover, these water heaters incorporate safety features such as high-temperature limit switches and a temperature and pressure relief valve, ensuring safe operation.

Another important characteristic of these models is their compliance with industry standards. The TG series meets or exceeds the stringent guidelines set forth by the American National Standards Institute (ANSI) and the National Sanitation Foundation (NSF), demonstrating Bradford White's commitment to quality and safety.

Moreover, the TG series is designed to be environmentally friendly, incorporating features that support lower emissions and energy consumption. By using high-efficiency burners and improved insulation, these models contribute to reduced greenhouse gas emissions, aligning with global sustainability goals.

In summary, the Bradford White Corp TG-180I-N(X), TG-237I-N(X), TG-150I-N(X), TG-237I-N(X)A, and TG-199I-N(X) water heaters are engineered for efficiency, durability, and safety. With advanced features and technologies, they provide reliable hot water solutions for a variety of settings, making them an excellent choice for consumers seeking high-quality water heating options.