Bradford-White Corp TG-180I-N(X), TG237I-N(X), TG-150I-N(X), TG-237I-N(X)A State Regulations

Page 12

State Regulations

NOTICE BEFORE INSTALLATION

Bradford White direct-vent appliance must be installed by a state qualified or licensed contractor. If you are not properly trained, you must not install this unit.

IMPORTANT: In the State of Massachusetts (248CMR 4.00 & 5.00)

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of venting, including but not limited to decks and porches, the following requirements must be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter must observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter must observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors. It is the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm must be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign must read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5308(2)(a)1 through 4.

12

Image 12
Contents TG-150I-NX, TG-180I-NX, TG-199I-NX, TG237I-NX & TG-237I-NXA Table of Contents Page Page If YOU Smell GAS Section II Specifications ModelDimensions 10.0 Section III Installation Instructions Unpacking Water Heater LocationRemove Carton Mount Water Heater on the Wall State Regulations Important In the State of Massachusetts 248CMR 4.00Section IV Water Connections Water QualityInstructions for Connections Page Approximate TIME/TEMPERATURE Relationships in Scalds Recommended Piping for a Basic Installation Recommended Piping for a Circulation Systems Recommended Piping for Power Failure Freeze Protection Recommended Piping for Freeze ProtectionPressure Relief Valve Page Page Section V Venting Venting Vent / Air Intake Terminal Locations Direct Vent Terminal LocationVenting System Installation Venting System LayoutPrior to the Installation of the EverHot Direct Vent System Horizontal Direct Vent InstallationsPage Vertical Direct Vent Installations Vertical Vent InstallationsCombustion Blower Dip Switch Settings Dip SwitchInstallation of Venting System Components Condensate Recommended Vent/Air Intake Terminal PositionJoint Connection Coping with CondensationCondensate Drain Shortening of Vent ExtensionsVenting Parts & Dimensions Components Needed for Direct Vent ApplicationsVent Pipe Clamp, p/n Page Measure Dimension to Fit Illustration Showing How to Properly Cut a Vent ExtensionFinal Installation of the Vent System Illustration Showing How to Cut the Vertical Vent to Fit Cut the Vent to FitDirect Vent Installation TG-237IModels Only Mounting the Vent System Vertical DischargeIllustration Showing the Installation of the Air Intake Horizontal Discharge for TG-237IModelsPage High Altitude Installations Page Adjustable Horizontal Concentric Termination Venting SuppliersManufacturer Product Manufacturer Product Appliance Vertical Horizontal AdapterSection VI GAS Connections GAS Meter Size Natural GAS only GAS Pressure RegulationGas Specific CorrectionInitial Operation and Testing Installer only Section VII Electrical Connections CPU Page Wiring Diagram for TG-237I-NXand TG-237I-NXAModels Temperature Controls Page Indicator Thermostat Installation of Remote Controls OptionalIllustration Showing Where to Connect Remote Control Harness Initial Operation and Testing of Controls Installer only Troubleshooting ElectricalWire Color Resistance Connector Pin NosHeat Exchanger and Outgoing Water Temperature Thermistors Flame RodFrost Protection Amp FusesSection Viii Operating Instructions General Instructions To Fill the Water HeaterSequence of Operation Lighting Instructions For Your Safety Read Before Operating Property damage, personal injury or loss of lifeWhat to do if YOU Smell GAS Operation InstructionsTemperature Adjustment Turning OFF the Water Heater for AN Extended Period of TimeTemperature Display Use Indicator Approximate TIME/TEMPERATURE Relationships in Scalds ScaldingFirst AID for Scalds Code Code DescriptionCode Code Description Flame Failure Code Section IX Maintenance Burner Flame AppearancePage Circulating Pump Water HeaterPage Section X Parts List Description Quantity Page Description Quantity Page Description Quantity Page Description Quantity TG-237I Models TG-237I-N TG-237I-X TG-237I-NA TG-237I-XA Page Description Quantity Page Description Quantity Page Description Quantity Section XI Warranty What will we do to correct problems? How do you get warranty assistance?What should you do to keep the warranty in effect? What will we not do?Page Page Fax/215-641-1670 Parts Fax/215-641-2180

TG-199I-N(X), TG-237I-N(X)A, TG-150I-N(X), TG237I-N(X), TG-180I-N(X) specifications

Bradford White Corp, a leader in water heating, offers a range of innovative water heaters, including the TG-180I-N(X), TG-237I-N(X), TG-150I-N(X), TG-237I-N(X)A, and TG-199I-N(X) models. These units are designed to deliver energy-efficient performance while ensuring reliability and ease of use for both residential and commercial applications.

One of the main features of the TG series is their robust design, which is built to withstand the rigors of daily use. These models are equipped with a durable steel tank that is glass-lined to prevent corrosion, ensuring a longer lifespan and reduced maintenance needs. The insulation system utilized in these water heaters is designed to minimize heat loss, contributing to overall energy efficiency.

In terms of technology, the TG series utilizes advanced gas burner systems that ensure optimal heating performance. The models feature an atmospheric venting system that is simple to install and maintain, offering great flexibility in terms of placement within a building. Additionally, the inclusion of Bradford White's signature Hydrojet® Total Performance System enhances overall efficiency by reducing sediment buildup, allowing for better heat transfer and increased performance.

Each model in this range is designed with user-friendly controls. The intuitive thermostat settings enable users to easily adjust the water temperature to meet their specific needs. Moreover, these water heaters incorporate safety features such as high-temperature limit switches and a temperature and pressure relief valve, ensuring safe operation.

Another important characteristic of these models is their compliance with industry standards. The TG series meets or exceeds the stringent guidelines set forth by the American National Standards Institute (ANSI) and the National Sanitation Foundation (NSF), demonstrating Bradford White's commitment to quality and safety.

Moreover, the TG series is designed to be environmentally friendly, incorporating features that support lower emissions and energy consumption. By using high-efficiency burners and improved insulation, these models contribute to reduced greenhouse gas emissions, aligning with global sustainability goals.

In summary, the Bradford White Corp TG-180I-N(X), TG-237I-N(X), TG-150I-N(X), TG-237I-N(X)A, and TG-199I-N(X) water heaters are engineered for efficiency, durability, and safety. With advanced features and technologies, they provide reliable hot water solutions for a variety of settings, making them an excellent choice for consumers seeking high-quality water heating options.