American Water Heater 71681, ADCG, DCG3-Series warranty Gas Pressure Testing

Page 15

Index

Gas Pressure Testing

Important: This water heater and its gas connection must be leak tested before placing the appliance in operation.

If the code requires the gas lines to be tested at a pressure of 14” W.C. or greater, the water heater and its manual shut-off valve must be disconnected from the gas supply piping system and the line capped.

If the gas lines are to be tested at a pressure less than 14” W.C., the water heater must be isolated from the gas supply piping system by closing its manual shut-off valve.

U.L. recognized fuel gas and carbon monoxide(CO) detectors are recommended in all applications and should be installed using the manufacturer’s instruc- tions and local codes, rules, or regulations.

Note: Air may be present in the gas lines and could prevent the burner from lighting on initial start-up. The gas lines should be purged of air by a qualified service technician after installation of the gas piping system.

Explosion Hazard

Have a qualified service technician make sure L.P. gas pressure does not exceed 13” water column.

Failure to do so can result in death, explosion, or fire.

15

 

15

Image 15
Contents Installation Instructions Use & Care Guide Table of Contents Unpacking the Water Heater Installation InstructionsInstaller and Owner Responsibilities Consumer InformationSite Location Installation RequirementsClearances and Accessibility Floors of the structure. Due to the normal corrosivePan must not restrict combustion airflow. Locate COMBUSTION/VENT Pipe System CombustionVenting Louvers and Grills Air RequirementsGeneral Combustion Air Supply DuctsEquipment Located in Confined Spaces ALL AIR from Outdoors Air Opening RequirementsFlue Outlet Reducer Draft Hood/Damper InstallationSpace Heating Piping InstallationTempering Valve Installation Water System PipingRelief valve if required Please note the following Discharge Line Temperature & Pressure Relief ValveGas Pressure GAS Supply and PipingGas Requirements Gas PipingGas Pressure Testing Electrical Connections Electrical InstallationWiring Diagram Vent Termination Installation ChecklistWater Heater Location Requirements Vent Pipe SystemOperating Your Water Heater Propane ModelsWater Heater Operation Stacking Water Temperature RegulationOperational Conditions Emergency Shut DownChecking the Draft Burner FlamesDraining and Flushing Maintenance of Your Water HeaterPilot Burner and Main Burner Assembly Inspection Check continuity PowerClean flame FaultySensor Resistance vs. Temperature Resistance K ohms Thermostat Troubleshooting Flow ChartPart Name and Description Repair Parts Illustration