American Water Heater ADCG, DCG3-Series, 71681 warranty Thermostat Troubleshooting Flow Chart

Page 25

 

 

DCG3 SERIES

Index

 

 

THERMOSTAT TROUBLESHOOTING FLOW CHART

 

 

 

 

 

 

 

 

 

No voltage or

 

 

 

 

 

 

 

 

 

 

 

 

low voltage from

 

 

 

 

 

 

 

 

 

 

 

 

purple wire

 

 

 

 

 

 

 

 

 

 

 

 

between

 

 

 

 

 

 

 

 

 

 

 

 

thermostat board

 

 

 

 

 

 

 

 

 

 

 

 

& ECO board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With an ohm meter

 

 

 

 

 

 

 

 

 

 

NO

set at X1, check

 

 

 

 

 

 

 

 

 

 

orange wires on

 

 

 

 

 

 

 

 

 

 

 

 

set pot. (3,000 ohms

 

 

 

 

 

 

 

 

 

 

 

 

at lowest setting and

 

 

 

 

 

 

 

 

 

 

 

 

0 ohms at highest

 

 

 

 

 

 

 

 

 

 

 

 

setting)

 

 

 

 

 

 

 

Replace

 

 

 

 

 

 

 

 

 

 

 

 

set pot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When slowly turning

 

 

 

 

 

 

 

 

 

HAS

set pot dial from low

 

 

 

 

 

 

 

 

 

to high, ohm reading

OK

 

 

 

 

 

BAD SPOT

should be a smooth

 

 

 

 

 

 

 

 

 

transition with no

 

 

 

 

 

 

 

 

 

 

 

 

skips, jumps or

 

 

 

Check ECO

Replace

 

 

 

glitches

 

 

 

and ICM

ECO board

 

 

 

 

 

 

 

 

NO

 

 

YES

NO

 

 

NO

Check orange wire

 

YES

 

 

 

 

Will ECO board

 

 

 

Is ECO light on?

from ECO board to

 

reset?

 

 

 

damper for 24V

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

YES

 

 

 

High water

Check

 

 

 

 

 

 

 

 

temperature

damper

 

 

 

 

 

 

 

 

Replace

bad

sensor(s)

OHMS

READING

NO GOOD

Take ohm reading from upper sensor and lowest sensor and compare reading with chart below.

(A temperature

reading from a water sample taken from T&P valve is also needed for this test)

OHMS OK

Check purple wire

NO

Replace

from thermostat

thermostat

for 24V

 

circuit

 

 

board

Sensor Resistance vs. Temperature

 

 

 

 

 

Resistance (K ohms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp.

0

1

2

3

 

4

5

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

0°C

32648

31026

29495

28049

 

26682

25389

24166

23010

21915

20879

10°C

19898

18968

18088

17253

 

16461

15710

14998

14322

13680

13071

20°C

12492

11942

11419

10922

 

10450

10000

9572

9165

8778

8409

30°C

8057

7722

7403

7099

 

6808

8532

6268

6016

5775

5546

40°C

5327

5117

4917

4726

 

4543

4368

4201

4042

3889

3742

50°C

3602

3468

3340

3217

 

3099

2986

2878

2774

2675

2579

60°C

2488

2400

2316

2235

 

2157

2083

2011

1942

1876

1813

70°C

1752

1693

1637

1582

 

1530

1480

1432

1385

1340

1297

80°C

1256

1216

1177

1140

 

1105

1070

1037

1005

974

944

90°C

916

888

861

835

 

810

786

763

741

719

698

40°F

26109

25400

24712

24045

 

23399

22771

22163

21573

21000

20445

50°F

19906

19383

18876

18383

 

17905

17440

16990

16553

16128

15715

70°F

11884

11592

11308

11032

 

10763

10502

10248

10000

9760

9526

90°F

7333

7165

7000

6839

 

6683

6531

6383

6238

6098

5961

100°F

5827

5697

5570

5446

 

5326

5208

5094

4982

4873

4767

120°F

3758

3679

3602

3527

 

3453

3382

3312

3244

3177

3112

140°F

2488

2439

2391

2344

 

2298

2253

2209

2166

2124

2083

160°F

1688

1656

1625

1595

 

1566

1537

1509

1481

1454

1427

180°F

1170

1150

1129

1110

 

1090

1071

1053

1035

1017

999

190°F

982

965

949

933

 

917

901

886

871

857

842

200°F

828

814

801

788

 

775

762

749

737

725

713

 

 

 

 

 

 

 

 

 

 

 

 

FCG3-0805

Copyright© by American Water Heater Company 2005. All rights reserved.

Image 25
Contents Installation Instructions Use & Care Guide Table of Contents Installer and Owner Responsibilities Installation InstructionsConsumer Information Unpacking the Water HeaterSite Location Installation RequirementsFloors of the structure. Due to the normal corrosive Clearances and AccessibilityPan must not restrict combustion airflow. Locate Combustion COMBUSTION/VENT Pipe SystemVenting General Air RequirementsCombustion Air Supply Ducts Louvers and GrillsEquipment Located in Confined Spaces ALL AIR from Outdoors Air Opening RequirementsFlue Outlet Reducer Draft Hood/Damper InstallationTempering Valve Installation Piping InstallationWater System Piping Space HeatingRelief valve if required Please note the following Discharge Line Temperature & Pressure Relief ValveGas Requirements GAS Supply and PipingGas Piping Gas PressureGas Pressure Testing Electrical Connections Electrical InstallationWiring Diagram Water Heater Location Requirements Installation ChecklistVent Pipe System Vent TerminationPropane Models Operating Your Water HeaterWater Heater Operation Stacking Water Temperature RegulationChecking the Draft Emergency Shut DownBurner Flames Operational ConditionsDraining and Flushing Maintenance of Your Water HeaterPilot Burner and Main Burner Assembly Inspection Clean flame PowerFaulty Check continuitySensor Resistance vs. Temperature Resistance K ohms Thermostat Troubleshooting Flow ChartPart Name and Description Repair Parts Illustration