WATER LINE CONNECTIONS

HEATER WIRING

This manual provides detailed installation diagrams (see back section of this manual) for typical methods of application for the water heaters.

The water heater may be installed by itself, or with a separate storage tank. When used with a separate storage tank, the circulation may be either by gravity or by means of circulating pump. When a circulating pump is used, it is important to note that the flow rate should be slow so that there will be a minimum of turbulence inside the heater.

CLOSED SYSTEM

CAUTION

A closed system will exist if a check valve (without bypass), pressure reducing valve (without bypass), or a water meter (without bypass) is installed in the cold water line between the water heater and street main (or well).

Excessive pressure may develop causing premature tank failure or intermittent relief valve operation. This type of failure is not covered by the limited warranty. An expansion tank or a similar device may be required in the inlet supply line between the appliance and the meter or valve to compensate for the thermal expansion of water under supply pressure.

If a water heater is installed in a closed water system, check local codes or contact the water supplier or local plumbing inspector on how to control this situation.

IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH 105°C WIRE OR ITS EQUIVALENT, EXCEPT IN THE BURNER HOUSING. IN THIS CASE USE 200°C WIRE.

THE COMPUTER CONTROL REQUIRES A SOURCE OF STABLE CLEAN ELECTRICITY FOR PROPER OPERATION. INSTALLING THE HEATER ON A BRANCH CIRCUIT THAT HAS ELECTRONIC NOISE, IS SUBJECT TO FLUCTUATIONS IN VOLTAGE LEVEL OR HAS AN APPLIANCE WHICH GENERATES EMF OF RFI INTERFERENCE CAN CAUSE THE CONTROLLER TO MALFUNCTION. A HIGH QUALITY POWER CONDITIONER MUST BE INSTALLED IF THE ABOVE CONDITIONS EXIST. MALFUNCTIONS CAUSED BY A POOR ELECTRICAL SUPPLY ARE NOT COVERED UNDER YOUR WARRANTY.

The controller is wired to the heater as shown in figures 16 & 17. The model and rating plate provides the electrical information needed to size the complete heater branch supply.

All electrical work must be installed in accordance with the National Electrical Code and local requirements.

When installed, the appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.

DO NOT ENERGIZE THE BRANCH CIRCUIT BEFORE THE HEATER TANK IS FILLED WITH WATER.

NOTE: This controller is Polarity Sensitive. If the Hot and Neutral Supply Voltage is reversed, the controller will not sense flame. Verify polarity before connecting the unit.

BSR BOARD (BTH - 250 ONLY) FIGURE 16

14

Image 14 Contents
Place These Instructions Adjacent to Heater Notify Owner to Keep for Future ReferenceROUGH-IN -DIMENSIONS Cyclone XHE BTH 120 BTUTable of Contents ForewordHigh Limit Switch E.C.O FeaturesWater Temperature Control Dishwashing Machine Requirement Installation InstructionsInsulation Blankets Circulating PumpAIR Requirements ClearancesHard Water Mechanical Exhausting of Room AIRPage PVC Elbow with Mesh Screen Direct Vent Terminal InstallationDirect Venting Masonry Side Walls Installation SequenceVent Pipe Manufacturers Installation Instructions Wooden Side WallsVertical Vent Terminal Installation Installation of Vent SystemVent Pipe Preparation Controls and SwitchesBlower Prover Switch GAS Piping System Connections BSR Board BTH 250 only Figure Water Line Connections Heater WiringClosed System Sequence of Operation Self Diagnostic ControllerOperation GAS Valve LED FlashingError Codes Fault ConditionsDisplay Flashes 05 when button is pressed Required Ability Initial START-UP Prior to Start UP Adjustment ProcedureOperating Instructions For Your Safety Read Before Operating Maintenance General InformationDraining Anode Inspection and ReplacementFlushing Sediment RemovalDrain Valve and Access Panels Vent SystemInstallation Diagrams Install in Accordance with Local Codes Page Page Page Manifold Kits Checklist and Service Information TROUBLE-SHOOTINGMotor RUNS, Burner Lights Momentarily Then Locks OUT Replacement PartsMotor will not RUN Noisy Burner OperationTank Service and Repair ExpensesClaim Procedure ALL Other PartsSmith Water Products CO., INC