A.O. Smith ARGSS02708 Vent Termination Figure, Power Vent Wiring Schematic Figure

Page 19

2. IftheVentTerminalisbeinginstalledontheoutsideofafinishedwall,itmay

the wall plate over the pipe to stop against the vent terminal. Place a bead

beeasiertomarkboththeinsideandoutsidewall.Aligntheholesbydrilling

of caulking (not supplied) around the gap between the pipe and cover

a hole through the center of the template from the inside through to the

plate. Apply enough to fill some of the gap between the pipe and wall.

outside.Thetemplatecannowbepositionedontheoutsidewallusingthe

Place some of the caulking on the back of the plate to hold it against the

drilled hole as a centering point for the template.

wall after installation. If the vent pipe is installed up to the wall, with a

 

coupling on the end against the wall opening, the pipe with the vent

3. A) MASONRY SIDE WALLS

terminal can be prepared for gluing before inserting through the wall. Slide

the pipe through the wall and insert into the coupling on the other side of

Chisel an opening approximately one half inch (1.3 cm) larger than

the wall, making sure that the vent terminal ends up pointed in the correct

the marked circle.

position, see Figure 18.

 

B) WOODEN SIDE WALLS

 

Drill a pilot hole approximately one quarter inch (0.64 cm) outside of

 

the marked circle. This pilot hole is used as a starting point for a

 

saws-all or sabre saw blade. Cut around the marked circle staying

 

approximately one quarter inch (0.64 cm) outside of the line. (This

 

will allow the vent to easily slide through the opening. The resulting

 

gap will be covered up by the Vent Terminal cover plate.) Repeat this

 

step on inside wall if necessary.

 

SEQUENCE OF INSTALLATIONS, FIGURE 18

 

Cut a length of PVC pipe about 3.5 inches (8.9 cm) longer than the wall

VENT TERMINATION - FIGURE 18.

thickness at the opening. Glue the vent terminal to this section of pipe. Slide

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

POWER VENT WIRING SCHEMATIC - FIGURE 19.

19

Image 19
Contents Residential GAS Water Heaters Power Vented GAS Models W/HOT Surface IgnitionImportant Definitions Safe INSTALLATION, USE and ServiceGeneral Safety General Safety Introduction Table of ContentsReplacement Parts and Deliming Products Typical InstallationRelief Valve Elbow Access Door Condensate Hose and Drain PAN Mixing Valve Usage Facts to Consider about the Location Locating the NEW Water HeaterInsulation Blankets ALL AIR from Outdoors See Figures 7, 8 ALL AIR from Inside Buildings SeeWater Piping Installing the NEW Water HeaterValve and Pipe Insulation if supplied TEMPERATURE-PRESSURE Relief ValveGAS Piping GAS Piping with Flexible ConnectorVenting Vent Pipe AssemblySediment Traps Filling the Water HeaterCanadian Horizontal Vent Clearances Vent Pipe Termination Horizontal Vent ClearancesVent Hoods MAY be Extremely HOT During Operation Condensate Planning the Vent SystemInstallation of Vent System Blower Assembly InstallationVent Terminal INSTALLATION, Sidewall Vent Termination Figure Power Vent Wiring Schematic FigureInstallation of Vertical Vent System Installation of Vent SYSTEM, SidewallVertical VAA Installations Recommended Vent Attenuation Assembly InstallationInch vent Horizontal VAA Installations Inch vent Vertical VAA InstallationsRecommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStep G Step BStep E Step FDo not TRY to Light the Burner by Hand Power Before ServicingBurner. Do not try to light the burner by hand What to do if YOU Smell GASD E F Temperature RegulationTemperature Indicators Temperature Adjustment Buttons DisplayStart UP Conditions For Your InformationOperational Conditions Burner Operation and Inspection Periodic MaintenanceBurner Cleaning Venting System InspectionAnode ROD Inspection TEMPERATURE-PRESSURE Relief Valve OperationDraining Leakage Checkpoints ServiceRepair Parts List Trouble Shooting Troubleshooting GuidelinesBurner flame, ensure flame is steady see #8 below Troubleshooting Guidelines Limitation on Implied Warranties Service and Labor ResponsibilityClaim Procedure Conditions and Exceptions

ARGSS02708 specifications

The A.O. Smith ARGSS02708 is a standout product in the realm of water heating solutions, designed with a focus on efficiency, durability, and user convenience. This particular model exemplifies the cutting-edge technology that A.O. Smith is known for, making it a preferred choice for both residential and commercial applications.

One of the main features of the ARGSS02708 is its high efficiency. The unit employs advanced insulation techniques, which minimize heat loss and ensure that energy is utilized effectively. With an Energy Factor that meets or exceeds industry standards, this water heater can significantly reduce energy bills, making it an environmentally friendly choice that doesn't compromise on performance.

Another notable characteristic of the A.O. Smith ARGSS02708 is its robust construction. Built with high-quality materials, this water heater is designed to withstand the wear and tear of daily use. The units are manufactured with a coating that helps resist corrosion, which not only prolongs the lifespan of the heater but also ensures that it operates safely and reliably over time.

The ARGSS02708 also incorporates smart technology that enhances user experience. It features an intelligent electronic control panel that allows for easy monitoring and adjusting of temperature settings, ensuring optimal comfort. This user-friendly interface provides real-time feedback, making it straightforward for users to manage their hot water needs efficiently.

Moreover, the model supports faster recovery rates compared to traditional water heaters. With its powerful heating elements, the ARGSS02708 can provide a steady supply of hot water at consistent temperatures, catering to households or businesses with high hot water demands.

Safety is another critical aspect that A.O. Smith prioritizes in the design of the ARGSS02708. The unit is equipped with multiple safety features, including thermal cut-off switches and pressure relief valves, which ensure safe operation under varying conditions.

In summary, the A.O. Smith ARGSS02708 emerges as an excellent option for those seeking a reliable, efficient, and user-friendly water heating solution. Its combination of advanced technology, durable construction, high efficiency, and safety features make it a commendable investment for anyone looking to enhance their water heating experience.