Genie POWERLIFT 900 Maintenance and Adjustments, Save These Instructions, Regular Maintenance

Page 16
Maintenance and Adjustments

6

Maintenance and Adjustments

 

 

If you have any questions, please do not hesitate to contact customer

A. Contact Reverse Test

service at: 1-800-35-GENIE or visit www.geniecompany.com

See page 9.

Important Safety Instructions

Important Safety Instructions WARNING

TO REDUCE THE RISK OF SEVERE injury or death, READ AND FOLLOW ALL INSTRUCTIONS.

1.NEVER let children operate or play with the door controls.

2.Keep remote away from children.

3.ALWAYS keep the moving door in sight and away from people and objects until door is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

4.NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.

5.Test opener monthly. The door MUST reverse on contact with a 1-1/2" high object (or a 2" x 4" board laid flat) at the center of doorway on the floor. After adjusting either the force or limit of travel, retest door opener. Failure to adjust the opener properly may cause severe injury or death.

6.When possible, use emergency release only when door is closed. Use caution when using this release with the door open. Weak or broken springs are capable of increasing the rate of door closure and increasing the risk of severe injury or death.

7.KEEP DOORS PROPERLY BALANCED. See your garage door Owner’s Manual. An improperly balanced door increases the risk of severe injury or death. Have a trained door system technician make repairs to cables, spring assemblies, and other hardware.

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS WARNING

• Garage door hardware (springs, cables, brackets, pulleys, etc.)

are under extreme pressure and tension.

• DO NOT attempt to repair or adjust door springs or any hardware,

and DO NOT OPERATE garage door automatically or manually if

door is improperly balance or springs are broken.

• CONTACT A TRAINED DOOR SYSTEM TECHNICIAN.

REGULAR MAINTENANCE WARNING

Use of any other wall control can cause unexpected operation of the door and loss of lighting feature. Locate wall console within sight of door and far enough from door to prevent contacting it while operating the console. Control must be at least 5 feet above floor to prevent small children from operating it.

B. Safe-T-Beam®(STB) System Check

Check that both the RED and GREEN LEDs are ON steady. This indicates the system is working properly. If both LEDs are not ON steady, check the appropriate items below:

STB red LED flashes.

Check for obstruction.

Check alignment.

Verify wire routing from STBs to STB connection in powerhead

Check for signal interference from another Safe-T-Beam®unit (for multiple door installations).

No STB red or green LED displayed.

Check wiring and wire connections.

If the system appears to be working properly, perform the check as follows:

1.Start the door closing.

2.Pass an object through the beam. The door should stop and reverse to the fully open position.

C.Door Balance (Spring Tension)

Perform the check as follows:

With the door closed, pull manual emergency release handle

DOWN and let go to release door carriage assembly from drive system.

Raise and lower the door manually—it should move freely and smoothly.

Raise door manually about 3' to 4' feet and let go.

REGULAR MAINTENANCE

Basic monthly maintenance tasks include:

• Contact Reverse

Safe-T-Beam® System Check

• Door balance

3' - 4'

Sectional Door

3' - 4'

One-Piece Door

• Lubricate door hardware

16

Door should remain stationary or move very slowly.

If door moves quickly, CONTACT A TRAINED DOOR SYSTEM TECHNICIAN to have your door springs serviced.

Close the door.

(continued next page)

G999-393 Manual-ScrewBeltChain-EN indd 16

7/13/12 10 17 AM

Image 16
Contents GARAGE DOOR OPENER MODELS SilentMax 1000/1200, CB 1000/1200, IntelliG 1000/1200Homelink and Car2U compatible OPERATION & MAINTENANCE MANUALSAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS Need help or have questions? Call usTable of Contents 1 Safety Information IMPORTANT SAFETY INSTRUCTIONSREAD THIS SAFETY INFORMATION OVERVIEW OF POTENTIAL HAZARDS2 Features SAFETY FEATURESopener features INFRARED PROTECTION FUNCTIONOverview of PoWERHEAD Controls 3 Required ProgrammingINTRODUCTION Located on bottom of PowerheadTRAVEL LIMITS Closing Garage Door Down Limitsround LED remains off will begin flashingOpening Garage Door Up Limits Release up arrow button + and the round LEDwill begin flashing PROGRAMWall Console / Overview In your carton you will find one of the following wall consolesSeries II Wall Consoles with White Buttons Series III Wall Consoles with Black ButtonsForce and Speed Control Contact Reverse AdjustmentContact Reverse Test 15 Release the Program Set button the long LED begins flashing purple REMOTES / New Intellicode 2 OpenersHOLD 2 seconds The Remote button is now programmed Repeat as necessary for additional RemotesEach Remote can be programmed for three door openers BASIC PROGRAMMING IS COMPLETE AND YOUR GARAGE DOOR IS READY TO USESetting Up a PIN Resetting PINPROGAMMING THE WIRELESS KEYPAD 4 Optional ProgrammingHOLD Clearing Memory FOR RemoTES2 seconds INTELLICODE 1 REMOTES Red = Intellicode 1 Green = IntellicodePress and release the Remote button 3 times on your older Genie door opener5 One-Piece Doors Attaching door braCket tO doorAttaching door arm tO door braCket Door centerlineMaintenance and Adjustments REGULAR MAINTENANCESAVE THESE INSTRUCTIONS Important Safety Instructions6 Maintenance and Adjustments REGULAR MAINTENANCE continuedCORRECTIVE MAINTENANCE Screw DriveDOWN FORCE FORCE Settings are resetBLUE then OFF Adjustment Guides continued Locating Safe-T-Beam PairsOne Door Garage Three Door Garage7 Wiring Diagram POWER CORDOPENING COVER MAY CAUSE ELECTRIC SHOCK ELECTRICAL SHOCKTroubleshooting OPERATION8 Troubleshooting POWERHEAD LEDS9 Warranty PowerMax 1200/1500, SC 1200/1500, TriloG 1200/1500, PowerLiftGPower 900, SilentMax 1000/1200, CB 1000/1200, IntelliG 1000/1200 LIMITED WARRANTYGenie-Net technology “tells” you Easy operation at your finger tipsConvenience, Security All in One “RETRO” REPLACEMENT
Related manuals
Manual 14 pages 5.59 Kb

TRILOG 1200/1500, SC 1200/1500, SILENTMAX 1000/1200, 1200/1500, GPOWER 900 specifications

The Genie TRUE, GPOWER 900, 1200, POWERLIFT 900, and 1500 are renowned products in the field of material handling, specifically designed to enhance efficiency and safety in various lifting applications.

The Genie TRUE is characterized by its innovative design that combines user-friendliness with advanced engineering. This model offers an impressive lift capacity while ensuring stability and performance. Its lightweight structure allows for easy maneuverability, making it ideal for both indoor and outdoor use. The Genie TRUE is equipped with a state-of-the-art control system that provides precise lifting, lowering, and positioning, ensuring maximum productivity for operators.

The GPOWER 900 and 1200 models stand out with their robust build and exceptional lifting capabilities. The GPOWER 900 is designed to handle loads up to 900 pounds, while the GPOWER 1200 can effortlessly lift up to 1200 pounds. Both models use advanced hydraulic systems for smooth operation, allowing for quick lifting cycles without compromising on power or safety. The ergonomic design of the GPOWER series minimizes operator fatigue, making it suitable for prolonged use in various work environments.

The POWERLIFT 900 and 1500 augment this lineup with their impressive features tailored for heavy-duty use. The POWERLIFT 900 can lift loads up to 900 pounds, making it ideal for medium-sized tasks. On the other hand, the POWERLIFT 1500 is engineered for heavier loads, boasting a capacity of 1500 pounds. Both models utilize cutting-edge overload protection technology, ensuring that safety is prioritized during use. Additionally, the POWERLIFT series features an intuitive interface that facilitates easy adjustments and control during operation.

Each of these models embodies the core values of Genie: reliability, innovation, and efficiency. They are designed to meet the varying demands of different industries, including construction, warehousing, and logistics. Their modular designs and interchangeable parts further enhance their versatility and longevity, making them a worthwhile investment for any business needing lifting solutions.

In summary, the Genie TRUE, GPOWER 900, 1200, POWERLIFT 900, and 1500 combine robust performance with safety and ease of use, making them ideal choices for any lifting task. Their reliability and advanced features are sure to meet the growing demands of modern workplaces.