8-15. MODULAR RECEIVER

Operating range between transmitter and opener may be reduced by electrical interference or radio signals in the area, concrete, steel or lead in and around the garage. To improve operating range you can select the best frequency for each particular installation. Plugging-in receiver module will help you to make changes simpler and faster. To replace receiver simply pull out existing module located on the top of the chassis, and slide in the new one. It will make a click- ing sound when the receiver module is locked into place.

Note: Each frequency receiver is supposed to have a match- ing transmitter. Reprogram the opener after you change the receiver module. (See section 8-18, p. 18).

8-16. CONNECT TO POWER

To reduce the risk of electric shock, your opener is provided with an insulated power cord with a 3-prong grounding plug. The cord must be connected to a standard grounding outlet. If there is no outlet available at the location, you must have a qualified electrician install an approved ground- ed outlet in this area.

To prevent electrocution or fire, installation

and wiring must be done in accordance with

local electrical and building codes. DO NOT use

an extension cord. DO NOT use a 3 to 2 plug

adapter. DO NOT modify or cut off the

grounding pin on the plug.

Plug the opener into a properly grounded outlet (Fig. 35).

An indicator light (LED #8) on the opener control panel will turn on showing that the power is “On” and the opener is ready to set the adjustments.

DO NOT operate or run the opener at this time.

PERMANENT WIRING CONNECTION:

(If required by your local electrical code)

If local codes require your opener to be connected via permanent wiring instead of a cord and plug, your opener must be converted, as shown in Fig. 36. Contact a qualified electrician to run the necessary wiring to your opener and to perform the electrical connections.

To prevent electrocution, disconnect the opener

from power and turn off power at circuit

breaker for the circuit you will be using

to connect to the opener.

Remove opener housing by removing screw underneath the control panel cover and two screws from back of housing, then pulling the housing away from the chassis.

Remove screw and unsnap the power cord strain relief cover by disengaging the tabs, and remove this part (save for reattachment later).

Cut the power cord leads close to where the cord enters opener, so that after cut, there is at least 6" of wiring remaining (white-neutral, black-hot, and green-ground) inside the opener connected to the varistor and trans- former.

Remove the cut power cord and plug and discard. Replace the strain relief cover by snapping tabs back into place.

Using a hammer and screwdriver or punch, knock out con- duit hole, and bring in the permanent wiring and conduit.

Fig. 35

Grounded

Outlet

 

Power Cord

Fig. 36

Strain Relief Cover

 

Conduit Nut

Remove

Wires: (remaining 6”)

Ground (Green)

Hot (Black)

Neutral (White)

Terminal Block

Secure conduit to chassis (method varies depending on type of conduit used).

Attach the incoming power leads (hot, neutral, and ground) to the remaining internal wires using suitable wire nuts (not provided).

Reinstall opener housing and secure housing with screws. Make sure that when reinstalling opener housing, no wires will be pinched between the housing and the chassis.

Complete the remaining installation.

Turn on power at breaker.

17

Image 17
Contents Digital Intelligence for the Garage M-4500 Tools Introduction Advanced FeaturesImportant Safety Information Garage and Door ToolsOne-Piece Door Sectional DoorOpener Package Contents Read and Follow ALL Installation Instructions Important Installation InstructionsMeasure and Mark Door Area Installation StepsInstall Header Bracket For ONE-PIECE Doors Install Door Bracket to DoorFor Sectional Doors Additional Step for ONE-PIECE Doors only Attach Rail to Opener HeadPosition Opener for Mounting Attach Rail to Header BracketSectional Doors and ONE-PIECE Doors with Track ONE-PIECE Doors Without TrackMount Opener to Ceiling Check Emergency Release Connect ARM to Door and TrolleySectional Doors ALL ONE-PIECE DoorsInstall Wall Control Panel Install Photo EYE Safety SystemMounting Photo EYE Directly to Wall Mounting Photo EYE to BracketDoorbell-Type Pushbutton Connecting Wires to PowerheadAntenna Wire Installation 40MHZ Install Light Bulbs and Lenses4700 4500Modular Receiver Connect to PowerPermanent Wiring Connection To Make or Change ANY Adjustment SET the AdjustmentsControl Panel Key to Icons Corresponding LEDsClose Travel Limit Fig Open Travel Limit FigUP Force Fig Down Force FigSafety Test Test Safety ReversalAlign and Test Photo Eyes AlignmentApply Labels to Inside of Garage Important Safety InstructionsTransmitter Mounting TransmittersMultiple Transmitters Code ChangeHomelink Transceiver Operation of Your OpenerRail Length Adjustment Tension AdjustmentSystem Parts Belt Rail AssemblyChain Rail Assembly Lamp Lens System Parts cont‘d Power Head AssemblyMidi & Mini Transmitters AccessoriesSituation Likely Cause and Solution Having a PROBLEM?LED Display After Code Problem Solution Pressing P Troubleshooting -FOR Professional Installer onlyMaintenance Steps Date Performed By Comments Maintenance and AdjustmentsMaintenance Record Need Help or SERVICE? Warranty InformationWarranty Service Opener Model Part Number Part Name

M-4700, M-4500 specifications

The Genie M-4500 and M-4700 are advanced aerial work platforms designed to enhance productivity and safety in various industrial and construction applications. Both models are well-known for their reliability and user-friendly features, making them popular choices for operators seeking efficient solutions for elevated work tasks.

The Genie M-4500 is a compact lift designed to elevate workers and materials up to 45 feet. One of its standout features is its impressive lifting capacity of up to 1,000 pounds, enabling it to safely handle heavy loads and multiple workers at once. The M-4500 is equipped with a unique four-wheel drive system, providing excellent traction on uneven surfaces, which is particularly beneficial for outdoor applications. The hydraulic scissor lift technology utilized in the M-4500 allows for stable and smooth vertical movements, minimizing the risk of accidents and enhancing overall safety.

On the other hand, the Genie M-4700 offers even greater lifting capabilities, reaching up to 47 feet with a comparable weight capacity of up to 1,000 pounds. With its extended platform size, the M-4700 is designed for bigger work areas, accommodating more tools and equipment. This model incorporates Genie’s advanced automatic leveling system, which ensures that the platform remains stable during operation, an essential feature when working on sloped or uneven terrain. The M-4700’s power options, including electric and diesel variants, provide operators with flexibility based on the specific site requirements.

Both models feature Genie’s patented Quick Positioning System, allowing for rapid setups and adjustments, further enhancing their operational efficiency. The control systems are intuitive, designed for ease of use, ensuring that operators can navigate the platforms effortlessly. Safety is also a primary concern, with integrated fall protection features, non-slip surfaces, and emergency descent systems.

In summary, the Genie M-4500 and M-4700 are top-tier aerial work platforms that combine lifting power, stability, and user-centric design to meet the demands of modern job sites. Their robust technology, combined with advanced safety features, ensures that users can complete tasks efficiently while minimizing risks. These models cater to various applications in construction, maintenance, and more, solidifying their position as essential tools in the aerial work equipment market.