Genie 1000 manual Red = IntelliCode 1 / Green = IntelliCode, FCC and IC Certified

Page 7

PROGRAMMING REMOTES

to New Intellicode® 2 Openers.

All type remotes program in the same way.

Bring remote(s) to powerhead location. For Car2U® and HomeLink®, park car outside the garage with the ignition key in the “ACCESSORY” position. Each button must

be programmed individually following steps below.

1

ACTION

LED INDICATION/RESULT

PROGRAM

 

 

Press & Hold for

 

 

 

2 seconds or until

BLUE

OFF

 

round LED turns blue. SET

OFF

PURPLE

 

 

 

FLASHING

PROGRAMMING INTELLICODE® 2 REMOTES to Intellicode® 1 (previous model) Openers.

The default setting of Intellicode® 2 must be changed.

The LED color displayed on the remote indicates the IntelliCode® mode.

Red = IntelliCode® 1 / Green = IntelliCode® 2

ACTION

LED INDICATION/RESULT

1 Select a button

 

NOT prorammed

 

to a new

 

Intellicode®2

 

opener

 

2

Choose a button on your

 

Both LEDs Off.

 

 

 

remote device. Press &

OFF

 

 

release it twice.

OFF

 

PURPLE

 

 

OFF

 

 

STEADY

 

 

 

3

Press & Release that same

 

 

 

DOOR MOVES

 

 

button again.

 

 

 

 

REMOTE BUTTON IS PROGRAMMED

NOTE: For additional openers—repeat the steps above using a different remote button for each.

2

Press & hold that button for until both the

RED & GREEN LEDs are ON. Release.

STAYS ON RED & GREEN

Press the same remote button 3 times.

RED WHEN BUTTON PRESSED

REMOTE BUTTON IS INTELLICODE® 1

FCC and IC CERTIFIED

This device complies with FCC Part 15 and RSS 210 of Industry Canada. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harful interference to radio or television reception, which may be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:

sRe-orient or relocate the receiver antenna.

sIncrease the separation between the opener and receiver.

sConnect the opener into an outlet on a circuit different from that to which the receiver is connected.

sConsult your local dealer.

3Find the Learn Code Button and

 

Learn Code Indicator LED on your

Red Indicator

 

door opener.

LED

 

If your Door Opener has a black

 

 

antenna wire and the serial

 

 

number does not start with

 

 

10 or higher, the Learn Code

Located

 

Button and Indicator LED are

 

on Opener

 

located near the antenna. (The

Housing

 

light lens may need to be

 

 

opened. If you use an external

 

 

receiver, it may need to be

Learn

 

opened to access the Learn

 

Code Button and Indicator LED.

Code

 

–If Door Opener does not have an

Button

 

 

 

Antenna, you have an External

 

 

Receiver. The External Receiver

 

 

cover must be removed to

 

 

access the Learn Code Button

 

 

and Indicator LED.

 

4

Press the

Red Indicator LED BLINKS

 

Lean Code

 

 

Button

 

5

Press the same

Red Indicator LED OFF

 

remote button

 

 

twice.

 

6

Press the same

 

 

remote button

DOOR MOVES

 

again.

 

 

REMOTE BUTTON IS PROGRAMMED TO OPENER

(Follow the TOP 2 steps above to shift back to Intellicode®2)

9/2011

©2011 The Genie Company

6

Image 7
Contents CHAIN/BELT This page Left Blank Safety Information Opener Features Safety FeaturesEnters into and selects programming menus Programming OverviewKeep people clear of opening while door is moving Programming LimitsBe programmed individually following steps below Default setting of Intellicode 2 must be changedRed = IntelliCode 1 / Green = IntelliCode FCC and IC CertifiedIndependent Light Control Button Indicator LightWall Console Overview Open/Close ButtonDoor Balance Spring Tension Contact Reverse TestSee Safe-T-Beam STB System CheckBelt Corrective Maintenance Change Light BulbsReset OPEN/CLOSE Travel Limit Remote Battery ReplacementDoors that start down, Stop and reverse before closing Adjustment Guide Force SettingsAdjustment Guide Speed Settings Doors with very stiff weather sealsPower Cord Reference Circuit Wiring DiagramSs Program remote to powerhead. See Troubleshooting Guide OperationFlashing OFFON/PURPLE OFF

1000 specifications

The Genie 1000 is a state-of-the-art aerial work platform designed to provide efficient aerial access solutions for various industrial and construction applications. Renowned for its robust build quality and advanced features, this unit combines functionality with ease of use, making it a favorite among professionals.

One of the standout features of the Genie 1000 is its compact design. With a narrow profile, it can easily navigate tight spaces and doorways, making it ideal for indoor and outdoor work environments. Its lightweight structure allows for easy transport between job sites, while still maintaining the strength and stability required for lifting tasks.

The Genie 1000 is equipped with an impressive maximum working height of 30 feet, allowing operators to reach elevated areas safely. Its platform capacity, which can accommodate up to 500 pounds, ensures that multiple workers and tools can be utilized simultaneously, enhancing productivity on the job. The unit also comes with a slide-out platform extension, granting additional reach when needed.

This aerial work platform employs advanced hydraulic technology, ensuring smooth and precise lifting and lowering operations. The Genie 1000 features a user-friendly control system that includes intuitive joystick controls, facilitating easy maneuverability. Safety is paramount, and this model is outfitted with various safety features, including an emergency stop button, guardrails, and a tilt alarm to prevent potential accidents during operation.

Another notable characteristic is its versatile power options. The Genie 1000 can be equipped with various power sources, including electric and diesel engines, depending on the operational requirements. This flexibility enables users to choose between an environmentally friendly electric model for indoor use and a robust diesel version for outdoor applications.

In terms of maintenance, the Genie 1000 is designed with serviceability in mind. Accessible components and clear maintenance points simplify routine checks and repairs, ensuring longevity and reliability.

Overall, the Genie 1000 stands out in the market for its exceptional performance, safety features, and ease of use. Its combination of compactness and capability makes it a vital tool in many industries, setting a new standard for aerial work platforms. Whether in construction, warehouse operations, or facility maintenance, the Genie 1000 is engineered to meet the demands of today’s workforce effectively.