MAINTENANCE OF YOUR OPENER
Once a Month:
•Repeat safety reverse test.
Make any necessary adjustments.
•Manually operate door. If it is unbalanced or binding, call for professional garage door service.
•Check to be sure door opens and closes fully. Set Limits and/or Force if necessary.
OPERATION OF YOUR OPENER
Your opener can be activated by any of the following devices:
•The green start button
Hold the button down until door starts to move.
•The Wall Control, Outside Keylock or Keyless Entry System (if you have installed any of these accessories).
•The Remote Control Transmitter or Wireless Wall Control (128LM)
Hold the push button down until the door starts to move.
When the Opener is activated by Remote Control, Green Start Button or Wall Control:
1.If open, the door will close. If closed, the door will open.
2.If closing, the door will stop.
3.If opening, the door will stop (allowing space for entry and exit of pets and for fresh air).
4.If the door has been stopped in a partially open or closed position, it will reverse direction.
5.If an obstruction is encountered while closing, the door will reverse.
6.If an obstruction is encountered while opening, the door will reverse and stop.
7.The optional Protector System™ uses an invisible beam which, when broken by an obstruction, causes a closing door to open and prevents an open door from closing. It is STRONGLY RECOMMENDED for homeowners with young children.
Allow a 15 minute cooling period after 4 minutes of continuous operation of the opener.
Opening the Door Manually:
Door should be fully closed if possible. Weak or broken springs could allow an open door to fall rapidly. Property damage or serious personal injury could result. The door can be opened manually by pulling the release cord down and across to engage the ball into the cup.
To reconnect the door, pull the release cord across and up to engage the opener .
The Opener Light Will Turn On:
1.when opener is initially plugged in;
2.when the power is briefly interrupted;
3.when the opener is activated.
The light turns off automatically after
SPECIFICATIONS
Input Voltage: | |
Rated Load: | 18Nm |
Max.Pull Force: | 550N |
Max. Door Weight | 100kg |
Idle Current: | less than 25mA @ 230VAC |
Drive: | DC gearmotor |
| permanent lubrication |
Max. Drum Rotations: | 5 |
Memory Registers: | 64 |
Operating Frequency: | 433.92MHz |
SPECIAL NOTE: Chamberlain strongly recommends that the protector system be installed on all garage door openers.
10