5 ONNECTING TO POWER
WARNING
To reduce the risk of electrical shock, this equipment has a grounded type plug that includes a third (grounding) pin. This plug will only fit a grounded type outlet. If you do not have a grounded outlet, contact a qualified licensed electrician to install one. DO NOT alter the plug in any way. The door opener must be properly grounded in order to prevent personal injury and damage to the components.
DO NOT remove motor cover. All work performed on motor must be done by a trained door system technician.
CAUTION
Check local building codes to make sure that you are not required to have your garage door opener permanently wired, with circuit breaker protection. If building codes require door opener to be permanently wired have a qualified licensed electrician connect power with permanent wiring.
WITH GROUNDED PLUG:
Plug the opener into a properly grounded electrical outlet (Fig.
WITH PERMANENT WIRING:
Instructions for Electrician.
Remove power from circuit.
Remove rear cover and motor cover.
–Remove four motor cover screws (Fig.
Remove existing power cord and strain relief from the 7/8" dia. hole and discard (Fig.
Connect permanent wiring to power head using 7/8" diameter hole.
–White to white/black to black/ground to green.
–Use only UL recognized wire nuts.
Wires inside the power head must be at least 6" in length.
Replace motor cover and rear cover and
NOTE: The Genie Company is not responsible for charges resulting from work preformed by an independent electrician.
WITH POWER SUPPLIED:
Check Safe-T-Beam® alignment (Fig. 5-4).
Insure that no part of door or its hardware is in path between lenses of source and sensor.
Insure that tops of lenses are between 5" - 6" above the floor (Fig.
Adjust the Red LED source by aiming the unit directly at the Green LED sensor. Use the adjustment screw located on the top of the source housing to make adjustments.
The Red LED source will blink if there is a misalignment. When the LED units are aligned the Red LED will remain ON continuously.
After the alignment is finished tighten the adjustment screws on
FOR
FIG. 5-1 Connect to power.
Motor Cover Screws
FIG. 5-2 Remove motor cover.
FIG. 5-3 Power cord strain relief.
CAUTION
Do NOT use an extension cord.
Do NOT use a portable generator. This product is designed to operate using standard household current.
Do NOT use alternate power supplies.
|
|
|
| o | m | fl | o | o | r |
|
| ax | fr |
| r | ||||
|
|
|
| ||||||
|
|
|
|
| |||||
6" | m | om | fl | oo |
| ||||
|
|
|
| ||||||
5" | min | fr |
|
|
|
|
|
| |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
FIG. |
INFRARED PROTECTION FUNCTION
1.When the garage door is opening, its movement will not be influenced if the
2.If the
3.When the garage door is closing, if
4.If the
PN# 3642036534, 02/26/2010 REV. 1 | 19 |
|