Chamberlain 1024, 1042, 1022 manual Do not USE AN Extension Cord

Page 4

PRE-INSTALLATION CHECK LIST FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM

Things to consider if you are planning to "Do-it-yourself." This opener is designed for use with SECTIONAL doors only.

In many cases you will be replacing an existing door opener with a new one, however, if this will be the first opener installed there are some pre-installation issues which need to be addressed. They are as follows:

The Genie Company recommends that you read and fully understand all information and instructions contained herein before choosing a "Do-it-yourself" installation. Any questions should be directed to The Genie Company or an authorized Genie® Dealer.

(The issue numbers below refer to the circled numbers in the illustrations on page 5.)

1Check your ceiling where the power head of your new unit will be mounted.

Plan how you will be mounting the power head. It is possible that ceiling joists may not be in the position needed with respect to the garage door opener. It may be necessary to add an additional bracket and fasteners (not included with your new door opener kit).

(Refer to Section 2.)

2Check the wall directly above the garage door. The door opener’s header bracket

must be securely fastened to this wall. Insure that the structure will provide a strong mounting location. (Refer to Section 2.)

3Check to see if the mounting location

for the Safe-T-Beam®System is clear from

obstruction and has a wood surface available for attaching the mounting brackets. The brackets may be attached to concrete if necessary but extra tools and special fasteners (not supplied) will be required. (Refer to Section 4 and 5.)

5You need a properly grounded 110-120 Volt power supply available. The outlet should be

no more than 3 feet from the power head once it is mounted. (Refer to Section 5.)

WARNING

DO NOT USE AN EXTENSION CORD!

DO NOT USE A PORTABLE GENERATOR! This product is designed to operate on standard house current.

DO NOT USE ALTERNATE POWER SUPPLIES.

6To avoid damage to your door and/or opener, make sure you disable and/or

remove any door locks, ropes, and/or cables (NOT door lift cables) prior to installing your opener. (Refer to Section 1.)

Remove

Remove

7Insure that your door is properly balanced and moving freely. (Refer to Section 2.)

NOTE: Mounting brackets must be installed within code specifications.

4Is your sectional garage door made of aluminum, light-weight steel, fiberglass

or glass panels? Additional support bracing must be added to these type doors. If this is the case, please contact the door manufacturer or authorized dealer so that they can furnish you with a "bracing kit." (Refer to Section 2.)

WARNING

To reduce the risk of injury to persons or damage to property - Use this opener only with sectional doors.

WARNING

If your door jams, binds, is improperly balanced or has a broken spring, have it repaired or adjusted by a trained door system technician. Door springs, cables, pulleys, brackets and associated hardware are under extreme tension and can cause serious injury or death.

8(NOT SHOWN) If your garage does not have a separate entry door, you should consider

an emergency release kit (GER-2) for installation on your garage door. (See emergency release kit installation notes on page 21.)

4

PN# 3642036534, 02/26/2010 REV. 1

 

Image 4
Contents Models 1022/1024/1042 Safety Information Opener Features Table of ContentsSafety Features Do not USE AN Extension Cord Typical Sectional Door Installation Recommended Tools Parts Identification Not Shown Full SizeDo not Return to Point of Purchase Chain Piece Rail Hardware Assembled ViewPener Assembly BagRail Assembly for Chain Drive Opener Assembly for Chain Drive Opener Finding header bracket mounting location Nstallation Header and Door Mounting BracketsDo not move door spring Mounting the header bracket Mounting the Opener Mounting the assemblyGetting started Install Door Arms Door BracketWall Console Installation Wall Console locationSecurely fasten wires AFE-T-BEAMSYSTEM Installation Mounting Safe-T-BeamSource Red LED and Sensor Green LED3b. Wiring pre-wired ‡ Route Safe-T-Beamwires through wire guideOnnecting to Power With Permanent WiringWith Power Supplied With Grounded PlugOOR Limits Close Travel LimitCarriage Lock Keyed Emergency Release Operation InstructionsTesting AdjustmentUP/DOWN Force Erase OPEN/CLOSE Travel LimitRogramming Remote Controls Lost or Stolen RemoteLight BULB/LENS Installation Battery replacementVisor clip Light bulbMaintenance Routine Monthly MaintenanceDoor balance Contact reverseCircuit Wiring Diagram Advertencia AvertissementTroubleshooting Guide Operation Problem What to doTroubleshooting Guide Power Head LED Possible Problem SolutionTransmitter Compliance Statement ModelS 1022/1024/1042 Limited Warranty