Troubleshooting Chart

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

1.Relieve the pressure.

2.Check all possible causes and problems before disassembling the pump.

PROBLEM

 

CAUSE

SOLUTION

 

 

 

The pump fails to oper-

Restricted air line or an inadequate air

Clear the line; increase the air supply.

ate.

 

 

supply; closed or clogged valves.

Check that the valves are open.

 

 

 

 

 

 

 

 

Obstructed fluid hose or gun;

Open, clear*; use a hose with a larger ID.

 

 

 

the fluid hose ID is too small.

 

 

 

 

 

 

 

 

 

Fluid has dried on the displacement rod.

Clean the rod; always stop the pump at the bottom

 

 

 

 

of its stroke;

 

 

 

 

keep the wet-cup 1/3 filled with a compatible sol-

 

 

 

 

vent.

 

 

 

 

 

 

 

 

Dirty, worn, or damaged motor parts.

Clean or repair; see the separate motor manual

 

 

 

 

308995.

 

 

 

 

 

The

pump

operates,

Restricted air line or an inadequate air

Clear the line; increase the air supply.

but the output is low on

supply; closed or clogged valves.

Check that the valves are open.

both strokes.

 

 

 

 

 

 

 

 

 

 

 

Obstructed fluid hose or gun;

Open, clear*; use a hose with a larger ID.

 

 

 

the fluid hose ID is too small.

 

 

 

 

 

 

 

 

 

Worn u–cup seals in the displacement

Replace the u–cup seals.

 

 

 

pump.

 

 

 

 

 

 

The

pump

operates,

Held open or worn intake valve.

Clear the valve; service.

but the output is low on

 

 

the downstroke.

 

 

 

 

 

 

 

The

pump

operates,

Held open or worn piston valve or u–cup

Clear the valve; replace the u–cup seals.

but the output is low on

seals.

 

the upstroke.

 

 

 

 

 

 

Erratic or accelerated

Exhausted fluid supply.

Refill the supply and prime the pump.

pump speed.

 

 

 

 

 

 

 

 

 

 

 

Held open or worn piston valve or u–cup

Clear the valve; replace the u–cup seals.

 

 

 

seals.

 

 

 

 

 

 

 

 

 

Held open or worn intake valve.

Clear the valve; service.

 

 

 

 

 

*To determine if the fluid hose or gun is obstructed, follow the Pressure Relief Procedure on page 8. Discon- nect the fluid hose and place a container at the pump fluid outlet to catch any fluid. Turn on the air just enough to start the pump. If the pump starts when the air is turned on, the obstruction is in the fluid hose or gun.

NOTE: If you experience air motor icing, call your Graco distributor.

308996 11

Image 11
Contents Part No Pump, Series B, 201 Ratio, with Falcon II Air Motor Instructions Parts ListImportant Safety Instructions Part No Pump, Series B, 101 Ratio, with Falcon Air MotorSymbols Table of ContentsSkin Injection Hazard Fire and Explosion Hazard General Information Prepare the Operator Grounding InstallationSystem Accessories Mounting AccessoriesFluid Line Accessories Air Line AccessoriesTypical Installation Pressure Relief Procedure Operation/MaintenanceFlush Pump Before First Use Starting and Adjusting PumpInstall the Spray Tip Explosion Hazard on Preventive Maintenance ScheduleShutdown and Care of the Pump FlushingProblem Cause Solution Troubleshooting ChartRequired Tools ServiceDisconnecting Displacement Pump Reconnecting the Displacement PumpModel 241594 Shown Disassembly Torque to 30-40 ft-lb 41-54 N.m Torque to 5-20 ft-lb 120-27 NSm *13 Lubricate Reassembly 9097A Description Qty PartsPart Description Qty Displacement Pump, Series BPiston Repair Kit 241828, for Falcon Pump Repair KitsRepair Kit 241597, for Falcon Pump Throat Seal Repair Kit 241827, for Falcon PumpPiston SST Conversion Kit 15B327, for Falcon Pump Piston Repair Kit 241830, for Falcon PumpModel 241595 Falcon ll Pump Technical DataModel 241594 Falcon Pump Falcon ll Performance ChartsLayout Dimensions Mounting HoleToll Free Graco Standard WarrantyGraco Information