Hitachi 308996J important safety instructions Skin Injection Hazard

Page 3

WARNING

SKIN INJECTION HAZARD

Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.

DFluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgical treatment.

DDo not point the gun at anyone or at any part of the body.

DDo not put your hand or fingers over the spray tip.

DDo not stop or deflect leaks with your hand, body, glove or rag.

DDo not “blow back” fluid; this is not an air spray system.

DAlways have the tip guard and the trigger guard on the gun when spraying.

DCheck the gun diffuser operation weekly. Refer to the gun manual.

DBe sure the gun trigger safety operates before spraying.

DDo not allow children to use this equipment.

DLock the gun trigger safety when you stop spraying.

DFollow the Pressure Relief Procedure on page 8 whenever you are instructed to relieve pres- sure; stop spraying; clean, check, or service the equipment; and install or clean the spray tip.

DTighten all fluid connections before operating the equipment.

DCheck the hoses, tubes, and couplings daily. Replace worn, loose, or damaged parts immediately. Permanently coupled hoses cannot be repaired; you must replace the entire hose.

DFluid hoses must have spring guards on both ends, to help protect them from rupture caused by kinks or bends near the couplings.

MOVING PARTS HAZARD

Moving parts, such as the air motor piston, can pinch or amputate your fingers.

DKeep clear of all moving parts when you start or operate the pump.

DBefore you service this equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly.

308996 3

Image 3
Contents Part No Pump, Series B, 201 Ratio, with Falcon II Air Motor Instructions Parts ListImportant Safety Instructions Part No Pump, Series B, 101 Ratio, with Falcon Air MotorSymbols Table of ContentsSkin Injection Hazard Fire and Explosion Hazard General Information Prepare the Operator Grounding InstallationSystem Accessories Mounting AccessoriesFluid Line Accessories Air Line AccessoriesTypical Installation Pressure Relief Procedure Operation/MaintenanceStarting and Adjusting Pump Install the Spray TipFlush Pump Before First Use Explosion Hazard on Preventive Maintenance ScheduleShutdown and Care of the Pump FlushingProblem Cause Solution Troubleshooting ChartRequired Tools ServiceDisconnecting Displacement Pump Reconnecting the Displacement PumpModel 241594 Shown Disassembly Torque to 30-40 ft-lb 41-54 N.m Torque to 5-20 ft-lb 120-27 NSm *13 Lubricate Reassembly 9097A Description Qty PartsPart Description Qty Displacement Pump, Series BPiston Repair Kit 241828, for Falcon Pump Repair KitsRepair Kit 241597, for Falcon Pump Throat Seal Repair Kit 241827, for Falcon PumpPiston SST Conversion Kit 15B327, for Falcon Pump Piston Repair Kit 241830, for Falcon PumpTechnical Data Model 241594 Falcon PumpModel 241595 Falcon ll Pump Falcon ll Performance ChartsLayout Dimensions Mounting HoleGraco Standard Warranty Graco InformationToll Free