Franklin 5870206300 installation manual SubDrive300 not to scale

Page 15

e SubDrive300 (not to scale)

ation Switch

Pump Size

3.0Hp

5.0Hp

ut to Motor

Red Yel Blk

(Brn) (Blue) (Blk)

(Output)

ump

Tank Precharge

Inflation ValveSensor Cable

Supplied

Pressure Tank

See Table 3 (page 16) for recommened minimum tank size

Pressure

Pressure Shut-off

Sensor Sensor

Pressure Gauge

To Residence

Pressure

Relief Valve

Drain Valve

Discharge into drain rated for max pump output at relief pressure

anklin ectric otor

WARNING

Submersible pumps can develop very high pressure in some situations. Always install a pressure relief valve able to pass full pump flow at 100 PSI. Install the pressure relief valve between the pump and pressure tank.

Pressure Setting Guide

Pressure Switch

 

Pressure Tank

Set Point (PSI)

 

Pre-Charge (PSI)

25

 

18

 

30

 

21

35

 

25

40

 

28

45

 

32

50 (Factory set)

 

35

55

 

39

60

 

42

65

 

46

70

 

49

75

 

53

80

 

56

15

Image 15
Contents SubDrive300 Contents SubDrive Models Description and Features Years Included ItemsConstant Pressure How It WorksSystem Diagnostics Unique FeaturesMotor Soft Start Drive Configuration Pump SizingPOS Underload Sensitivity Underload Sensitivity for Shallow WellsBefore Getting Started Min Controller Location SelectionCorrectincorrect Circuit Breaker and Wire Sizing Quick Reference Guide SubDrive300 not to scale Minimum Tank Size Pressure TankMounting Screws Installation ProcedureMotor Lead Connections Wiring ConnectionsPower and Pressure Sensor Connections Pressure Sensor Pressure Shut-off Sensor Leaky Systems Start-Up and OperationFor Use With C SpecificationsMounting Dimensions Flashes Fault Possible Cause Corrective Action Diagnostic Fault CodesSymptom Possible Cause Corrective Action System Troubleshooting GuideOver-Temperature Foldback Underload Smart ResetTOLL-FREE Help from a Friend 400 E. Spring Street Bluffton, Tel