Franklin 5870206300 installation manual Installation Procedure, Mounting Screws

Page 17

Installation Procedure

1.Disconnect electrical power at the main breaker.

2.Drain the system (if applicable).

3.Install the pressure sensor and pressure shut-off sensor at the pressure tank tee downstream of the pressure tank (the pressure tank should be between the pressure sensor and the pump). The sensors have a ¼-18 National Pipe Thread (NPT) connection.

The pressure sensors should not be installed in an inverted orientation (up-side down). Make sure the pressure sensor and tank are not located more than 3 feet off the main piping.

4.Install the unit to the wall using four mounting screws (not included) as shown in Figure 1 below. Remove the SubDrive lid by removing the eight lid screws.

Mounting Screw Locations

(User Supplied Quantity 4)

Lid Screws (Included Quantity 8)

Figure 1: Mounting Screws

17

Image 17
Contents SubDrive300 Contents SubDrive Models Description and Features Years Included ItemsConstant Pressure How It WorksMotor Soft Start System DiagnosticsUnique Features Drive Configuration Pump SizingPOS Underload Sensitivity Underload Sensitivity for Shallow WellsBefore Getting Started Min Controller Location SelectionCorrectincorrect Circuit Breaker and Wire Sizing Quick Reference Guide SubDrive300 not to scale Minimum Tank Size Pressure TankMounting Screws Installation ProcedureMotor Lead Connections Wiring ConnectionsPower and Pressure Sensor Connections Pressure Sensor Pressure Shut-off Sensor Leaky Systems Start-Up and OperationFor Use With C SpecificationsMounting Dimensions Flashes Fault Possible Cause Corrective Action Diagnostic Fault CodesSymptom Possible Cause Corrective Action System Troubleshooting GuideOver-Temperature Foldback Underload Smart ResetTOLL-FREE Help from a Friend 400 E. Spring Street Bluffton, Tel