Franklin 5870206300 installation manual Power and Pressure Sensor Connections

Page 19

From Power Source

L1

L2

 

(Input)

PRESSURE

SHUT-OFF

NO

NO

SENSOR

 

 

 

 

RELAY

 

 

 

 

COM

 

PFC

INV

 

 

FAN

FAN

 

SW1

 

SW2

 

Sensor Connection

PRESSURE

PRESSURE

SENSOR

SHUT-OFF

Red Blk Wh Grn

Figure 3: Power and Pressure

Sensor Connections

6.Feed the 230 VAC power leads through the bottom left side of the SubDrive300 controller and connect them to the terminals marked L1, L2, and GND (Figure 3).

A 10-foot section of pressure sensor cable is provided with the controller, but it is possible to use similar 22 AWG wire for distances up to 100 feet from the pressure sensor. A 100-foot section of pressure sensor cable is available as an accessory.

7.Feedthepressuresensorleadsthroughthesmalleropeninglocatedinthe bottom middle of the SubDrive300 unit and press on the quick connect terminals.

8.Verify that the SubDrive300 unit is properly configured for the horsepower rating of the motor and pump being used. Please refer to the section on Pump Sizing for information on drive configuration.

9.Replace the lid. Do not over-tighten the screws.

19

Image 19
Contents SubDrive300 Contents SubDrive Models Description and Features Years Included ItemsConstant Pressure How It WorksUnique Features System DiagnosticsMotor Soft Start Drive Configuration Pump SizingPOS Underload Sensitivity Underload Sensitivity for Shallow WellsBefore Getting Started Min Controller Location SelectionCorrectincorrect Circuit Breaker and Wire Sizing Quick Reference Guide SubDrive300 not to scale Minimum Tank Size Pressure TankMounting Screws Installation ProcedureMotor Lead Connections Wiring ConnectionsPower and Pressure Sensor Connections Pressure Sensor Pressure Shut-off Sensor Leaky Systems Start-Up and OperationFor Use With C SpecificationsMounting Dimensions Flashes Fault Possible Cause Corrective Action Diagnostic Fault CodesSymptom Possible Cause Corrective Action System Troubleshooting GuideOver-Temperature Foldback Underload Smart ResetTOLL-FREE Help from a Friend 400 E. Spring Street Bluffton, Tel