Specifications

 

Voltage

190-260 VAC

 

 

 

 

Frequency

50/60 Hz

Input from

 

 

Current (max)

36 Amps (RMS)

Power Source

 

 

Power Factor

1.0 (constant)

(single-phase)

 

 

 

 

Power (idle)

65 Watts

 

 

 

 

Power (max)

7200 Watts

 

 

 

 

Voltage

Adjusts with Frequency

 

 

 

Output to Motor

Frequency Range

30-80 Hz (3 Hp pump)

(three-phase)

30-60 Hz (5 Hp pump)

 

 

 

 

 

Current (max)

17.8 Amps (RMS, each phase)

 

 

 

Pressure Setting

Factory preset

50 psi

 

 

Adjustment range

25-80 psi

 

 

 

 

 

NEMA 4 (indoor/outdoor)

Model 5870206300

 

 

 

Operating (A)

Temperature (at 230 VAC

-13 to 125°F

input)

(-25 to 51°C)

Conditions

 

 

 

Relative Humidity

0-100%, non-condensing or

 

condensing

 

 

 

 

 

Controller Size (B)

Outer dimensions

14¾” H × 15¾” W × 8¾” D

 

 

(approximate)

Weight

34 lbs (15.5kg)

 

 

 

 

 

Pump (60Hz)

3.0 Hp (default)

For Use With (C)

5.0 Hp

 

 

 

 

Motor (3-phase)

234317- series (5.0 Hp)

 

 

 

NOTES: (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection on Page 11.

(B)Refer to Page 23 for detailed mounting dimensions.

(C)If a pump other than the default rating is used, refer to Page 8 for drive configuration.

22

Image 22
Contents SubDrive300 Contents SubDrive Models Description and Features Included Items YearsHow It Works Constant PressureUnique Features System DiagnosticsMotor Soft Start Pump Sizing Drive ConfigurationUnderload Sensitivity for Shallow Wells POS Underload SensitivityBefore Getting Started Controller Location Selection MinCorrectincorrect Circuit Breaker and Wire Sizing Quick Reference Guide SubDrive300 not to scale Pressure Tank Minimum Tank SizeInstallation Procedure Mounting ScrewsWiring Connections Motor Lead ConnectionsPower and Pressure Sensor Connections Pressure Sensor Pressure Shut-off Sensor Start-Up and Operation Leaky SystemsSpecifications For Use With CMounting Dimensions Diagnostic Fault Codes Flashes Fault Possible Cause Corrective ActionSystem Troubleshooting Guide Symptom Possible Cause Corrective ActionUnderload Smart Reset Over-Temperature FoldbackTOLL-FREE Help from a Friend 400 E. Spring Street Bluffton, Tel